Murata SR626W

Manual de instruções da bateria de relógio Murata 376 SR626W de óxido de prata

Model: SR626W | Brand: Murata

1. Introdução

This manual provides essential information for the safe and effective use of Murata 376 SR626W 1.55V Silver Oxide Watch Button Cell batteries. These batteries are designed for watches and other small electronic devices requiring a stable and reliable power source. Murata, a leader in micro-battery technology, ensures high performance and reliability in its products.

Murata 376 SR626W Silver Oxide Watch Batteries in Blister Pack

Figure 1: Murata 376 SR626W Silver Oxide Watch Batteries in a blister pack, showing five individual cells.

2. Informações de segurança

Please read and understand all safety precautions before handling or installing batteries. Failure to follow these instructions may result in fire, explosion, leakage, or other hazards.

  • Mantenha fora do alcance de crianças: Pilhas tipo botão podem ser engolidas. Em caso de ingestão, procure atendimento médico imediatamente.
  • Não recarregue: These batteries are not rechargeable. Attempting to recharge may cause leakage or explosion.
  • Não desmonte nem modifique: Tampering with batteries can lead to internal short circuits, leakage, or explosion.
  • Do not expose to heat: Avoid direct sunlight, high temperatures, or fire. This can cause leakage, explosion, or fire.
  • Não provoque curto-circuito: Keep batteries away from metal objects that could cause a short circuit.
  • Observe a polaridade: Always insert batteries with the correct positive (+) and negative (-) orientation as indicated by the device.
  • Evite o contato com a pele e os olhos: If battery fluid comes into contact with skin or eyes, immediately flush with plenty of water and seek medical attention.

3. Instalação

Installing a watch battery typically requires specific tools and careful handling. If you are unsure, it is recommended to consult a professional watch repair technician.

  1. Prepare seu espaço de trabalho: Work on a clean, well-lit surface. Use a soft cloth or mat to prevent scratching your watch.
  2. Open the watch case: Depending on your watch model, this may involve unscrewing a case back, prying it open with a case knife, or using a specialized tool.
  3. Remova a bateria antiga: Carefully note the orientation of the old battery. Use non-metallic tweezers or a small screwdriver to gently lift and remove it. Avoid touching the watch movement with bare hands.
  4. Insert the new battery: Place the Murata SR626W battery into the battery compartment, ensuring the correct polarity (usually positive side up). Use non-metallic tweezers to avoid scratching the battery or watch components.
  5. Secure the battery: Ensure the battery is seated correctly and any retaining clips are re-engaged.
  6. Close the watch case: Carefully re-attach the watch case back, ensuring a secure fit to maintain water resistance (if applicable).
Watch battery being installed with tweezers into a watch movement

Figure 2: Illustration of a watch battery being carefully installed into a watch movement using tweezers.

4. Informações Operacionais

Murata SR626W batteries are designed for consistent and reliable power delivery in watches. They are silver oxide batteries, known for their stable voltage output and long shelf life.

  • Volumetage Estabilidade: Silver oxide batteries maintain a stable voltage throughout their discharge cycle, which is crucial for accurate timekeeping in watches.
  • Livre de mercúrio: Murata batteries are manufactured without mercury, lead, or cadmium, reflecting a commitment to environmental responsibility.
Close-up of a Murata watch battery with 'Hg 0%' indicating mercury-free composition

Figura 3: Um close-up view of a Murata watch battery, highlighting the 'Hg 0%' marking, signifying its mercury-free composition.

5. Manutenção e armazenamento

Proper handling and storage can extend the shelf life of your Murata batteries and ensure safety.

  • Armazenar: Guarde as pilhas não utilizadas na embalagem original, em local fresco e seco, longe da luz solar direta e de temperaturas extremas.
  • Avoid mixing: Do not mix new and old batteries, or batteries of different types or brands.
  • Limpar lentes de contato: Before installation, ensure the battery contacts in your device are clean and free of corrosion.

6. Solução De Problemas

If your device does not function after battery replacement, consider the following:

  • Polaridade incorreta: Verifique novamente se a bateria está inserida com a orientação correta, positivo (+) e negativo (-).
  • Poor contact: Ensure the battery is seated firmly in its compartment and that the contacts are clean and making proper connection.
  • Device issue: If the battery is correctly installed and the device still does not work, the issue may lie with the device itself, not the battery.
  • Battery expiration: Check the expiration date on the battery packaging.

7. Especificações

EspecificaçãoDetalhe
Número do modeloSR626W (also known as 376)
Tipo de BateriaSilver Oxide Button Cell
Vol Nominaltage1.55V
Capacidade28 mAh
QuímicaSilver Oxide (0% Mercury)
Uso recomendadoRelógios
FabricanteMurata
Various Murata watch battery models listed alongside a watch movement and batteries

Figure 4: A visual representation of various Murata watch battery models, including the SR626W, alongside a watch movement.

8. Descarte

Do not dispose of batteries in household waste. Batteries contain materials that can be harmful to the environment if not disposed of properly. Please recycle batteries at designated collection points or return them to appropriate recycling facilities. Consult your local regulations for proper battery disposal.

9. Garantia e Suporte

Murata batteries are manufactured to high-quality standards. For warranty information or technical support, please refer to the official Murata webNo site ou entre em contato com o revendedor. Guarde o comprovante de compra como prova de aquisição.

Murata SR626SW battery integrated into a watch movement, emphasizing quality and mercury-free status

Figure 5: A Murata SR626SW battery shown within a watch movement, illustrating its role as a reliable power source.

Documentos relacionados - SR626W

Préview Manual de instalação do Murata 2CX: Padrão de aterramento, layout de PIN, volume de fornecimentotage, Antena
Guia de instalação do módulo Murata 2CX, detalhando o padrão de terreno, layout do PIN, volume de fornecimentotagEspecificações e considerações sobre o projeto da antena. Inclui números de identificação FCC e IC.
Préview Murata 2JV Bluetooth Low Energy Module User Manual
User manual for the Murata 2JV Bluetooth Low Energy Module, covering FCC compliance, terminal configurations, dimensions, marking, and operating conditions.
Préview Guia de Introdução ao SDK FreeRTOS da AWS para Murata TypeABR
This guide provides essential instructions for software and firmware engineers to effectively utilize the AWS FreeRTOS SDK with the Murata TypeABR module. It details the process of setting up the development environment, building AWS demos, running firmware, and monitoring cloud communications.
Préview Murata LBUA5QJ2AB UWB+BLE Module User Manual and Compliance Information
User manual and regulatory compliance information for the Murata LBUA5QJ2AB UWB+BLE module, including FCC and IC certifications, antenna application guidance, and installation requirements for host product manufacturers.
Préview Murata Chip Ferrite Bead BLM15PX Series Specification
Reference specification for Murata's BLM15PX series chip ferrite beads, designed for automotive electronics and compliant with AEC-Q200 standards. Includes detailed part numbering, ratings, electrical performance, testing conditions, dimensions, marking, packaging, and usage precautions.
Préview Manual do usuário da biblioteca Murata para o ambiente de design Cadence AWR (Microwave Office)
Manual do usuário para instalação e uso da biblioteca de modelos elétricos de indutores de RF e MLCC Murata, disponível no AWR Design Environment Microwave Office (MWO) da Cadence. Abrange o ambiente de operação, as etapas de instalação e o uso.