BFT P125002 SB-BAT

Manual do usuário do kit de bateria de reserva BFT Gate Opener P125002 SB-BAT 24V DC

Model: P125002 SB-BAT

1. Produto acabadoview

The BFT SB-BAT (P125002) is a 24v DC battery backup system designed to ensure continuous operation of your gate opener even during power outages. This kit provides a reliable power source, activating automatically when the main power supply is interrupted and recharging when power is restored.

It is compatible with various BFT gate opener models, including the Deimos BT series, VIRGO - LINX, EOS-SCE, HYDRA N, DEIMOS BT-QSC D-NETTUNO S, SB BAT/SB CARBAT (DEIMOS BT-SB 300), BT BAT 2 (URANO BT ARES 1000 & ARES 1500) NETTUNO B, VENERE D, ARGO, LIBRA C MA - LIBRA C LX.

BFT P125002 SB-BAT Battery Backup Kit components

Figure 1: Contents of the BFT P125002 SB-BAT Battery Backup Kit, including batteries, wiring, and mounting hardware.

2. Configuração e instalação

Installation of the BFT SB-BAT kit is designed to be straightforward. It integrates with your existing BFT gate opener system.

2.1. Precauções de segurança

2.2. Etapas de instalação

  1. Descompacte os componentes: Carefully remove all items from the packaging. Verify all components are present as shown in Figure 1.
  2. Mount the Battery Housing: Securely mount the battery housing unit near your gate opener's control board, ensuring it is protected from environmental elements.
  3. Conecte as baterias: Insert the two 12V 1.2Ah batteries into the housing. Connect them according to the wiring diagram provided with the kit (typically in series to achieve 24V DC).
  4. Connect to Gate Opener: Connect the battery backup system's wiring to the designated battery input terminals on your BFT gate opener's control board. Consult your gate opener's manual for precise terminal locations.
  5. Fiação segura: Ensure all wiring is neatly routed and secured to prevent accidental disconnections or damage.
  6. Restaurar energia: Once all connections are secure and verified, restore main power to the gate opener. The smart charger board will begin charging the batteries.
Close-up of BFT P125002 SB-BAT components including batteries and wiring

Figura 2: Mais detalhes view of the battery backup kit components, highlighting the batteries and connection wires.

3. Operação

The BFT SB-BAT battery backup system operates automatically to provide uninterrupted gate functionality.

4. Manutenção

Regular maintenance ensures the longevity and reliability of your battery backup system.

5. Solução De Problemas

This section addresses common issues you might encounter with your BFT SB-BAT battery backup kit.

ProblemaPossível causaSolução
O portão não funciona durante a falta de energia.tage.
  • As baterias não estão carregadas.
  • Conexões de fiação soltas ou incorretas.
  • Batteries are at end of life.
  • Fusível queimado.
  • Ensure main power is connected and the charger board is functioning. Allow 12-14 hours for full charge.
  • Check all wiring connections between the battery kit and the gate opener.
  • Test batteries; replace if necessary.
  • Check and replace the 20A fuse if blown.
As baterias parecem não estar carregando.
  • Main power supply issue.
  • Faulty charger board.
  • Conexão incorreta da bateria.
  • Verify main power to the gate opener.
  • Contact BFT support for charger board diagnosis.
  • Recheck battery wiring according to the manual.

6. Especificações

Key technical specifications for the BFT SB-BAT (P125002) battery backup system:

7. Garantia e Suporte

For warranty information or technical support, please refer to the documentation included with your purchase or contact BFT customer service directly. Keep your proof of purchase for warranty claims.

You can find more information about BFT products on their official website ou por meio de distribuidores autorizados.

Documentos relacionados - P125002 SB-BAT

Préview Sistema de Automação Eletromecânica para Portões BFT DEIMOS BT UL/CSA
Descubra o BFT DEIMOS BT UL/CSA, um sistema de automatização eletromecânica para portões de correr com cremalheira. Com tecnologia inteligente, funcionamento seguro em 24V e instalação simplificada, este sistema aumenta a segurança e a comodidade do seu portão. Explore as suas especificações técnicas e os acessórios disponíveis para aplicações residenciais e comerciais.
Préview Manual de Instalação do Automatizador de Portão de Batente BFT VIRGO
Guia completo de instalação e utilização do sistema de automatização de portões de batente BFT VIRGO, abrangendo segurança, especificações técnicas, procedimentos de instalação, programação e manutenção.
Préview Guia de Instalação do Sistema de Rádio Controle BFT CLONIX1-2 e MITTO 2-4 433MHz
Guia de instalação completo para o receptor BFT CLONIX1-2 e os transmissores de controle remoto MITTO 2-4 de 433 MHz, abrangendo programação, clonagem, segurança e especificações técnicas para automatização de portões e portas.
Préview Manual de instalação BFT THALIA: Quadro de comando para cancelamento automático
Esta guia dettagliata ilustra a instalação e configuração do quadro de comandos BFT THALIA, projetada para cancelamento automático e porta. Inclui técnicas específicas, esquemas de conexão e instruções operacionais para garantir um funcionamento seguro e eficiente.
Préview Guia de Referência Rápida UL do Kit BFT Phobos BT
Guia de referência rápida para o sistema de abertura automática de portão BFT Phobos BT Kit UL, abrangendo instalação, fiação, programação e solução de problemas.
Préview Instruções de codificação do controle remoto BFT MITTO 2B | Controles remotos retrô
Guia passo a passo para codificar controles remotos BFT MITTO 2B para abridores de portão, abrangendo os métodos existentes para controle remoto e tela LCD do receptor. Inclui dicas de solução de problemas.