1. Produto acabadoview
The EXCEL Tankless Gas Water Heater is designed to provide instant hot water for various applications, including small apartments, lofts, flats, RVs, and mobile homes. This unit operates on Propane (LPG) and features exclusive low water pressure startup technology, requiring only 2 PSI of water pressure to activate. Its vent-free design eliminates the need for complex and costly flue installations, making it a convenient and energy-efficient solution for on-demand hot water.

Figura 1.1: Frente e lateral view of the EXCEL Tankless Gas Water Heater, showcasinSeu design compacto e botões de controle.
Principais características:
- Propane Gas (LPG) Unit: Designed for use with liquid propane gas.
- Low Water Pressure Startup: Activates with as little as 2 PSI of water pressure, ideal for areas with fluctuating water supply. This is achieved through a magnetic water flow sensor, unlike older units that rely on rubber diaphragms requiring higher pressure.
- Vent-Free Technology: Does not require a traditional flue or ductwork for exhaust. Equipped with an Oxygen Depletion Safety (ODS) shutoff and an exclusive 20-minute safety shutoff feature for indoor installation with proper ventilation.
- Tamanho compacto: Dimensions are approximately 12.8 inches (front width) x 8 inches (depth) x 18.75 inches (height), allowing for flexible installation.
- Ignição Automática: Powered by 2 D-size batteries (included) for automatic ignition upon water flow.
- Economia de energia e água: Delivers hot water instantly, reducing waste.
2. Informações de segurança
Read and understand all safety warnings and instructions before installing, operating, or performing maintenance on this appliance. Failure to follow these instructions could result in property damage, personal injury, or death.
Precauções Gerais de Segurança:
- Este aparelho deve ser instalado por um profissional qualificado, em conformidade com todos os códigos e regulamentos locais.
- Ensure adequate ventilation when installing the unit indoors due to its vent-free design.
- Não armazene ou use gasolina ou outros vapores e líquidos inflamáveis nas proximidades deste ou de qualquer outro aparelho.
- Check for gas leaks using a soapy water solution after installation and during maintenance. Never use an open flame.
- The unit is equipped with an Oxygen Depletion Safety (ODS) shutoff system and a 20-minute safety shutoff feature. Do not bypass or tamper com esses dispositivos de segurança.
- Ensure proper battery installation for automatic ignition. Use new, high-quality D-size alkaline batteries.
- Protect the unit from freezing temperatures. Drain the unit if it will be exposed to freezing conditions (see Maintenance section).
- Este produto contém substâncias químicas que o Estado da Califórnia reconhece como causadoras de câncer, defeitos congênitos ou outros danos reprodutivos (Aviso da Proposição 65).
3. Configuração e instalação
Proper installation is critical for the safe and efficient operation of your EXCEL Tankless Gas Water Heater. Refer to the diagrams below for connection points.
Identificação do componente:

Figure 3.1: Connection points at the bottom of the unit.

Figure 3.2: Location of the Winter Drain and Battery Box.
Etapas de instalação:
- Montagem: Securely mount the unit to a wall using appropriate hardware. Ensure the mounting surface can support the weight of the unit when filled with water.
- Conexões de água:
- Conecte a linha de abastecimento de água fria ao Entrada de água fria.
- Connect the hot water output line to the Saída de água quente.
- Ensure all water connections are tight and leak-free. Use appropriate sealing tape or compound.
- Conexão de gás:
- Connect the Propane (LPG) gas supply line to the Entrada de gás. The unit includes an LPG Brass Fitting for a ⅜" Flare connection.
- Verify all gas connections are secure and test for leaks using a soapy water solution.
- Instalação da bateria: Open the battery box and insert two D-size batteries. Ensure correct polarity. These batteries power the automatic ignition system.
- Ventilação: For indoor installations, ensure the area has adequate ventilation as this is a vent-free appliance.

Figura 3.3: interno view highlighting the magnetic water flow sensor, which enables low water pressure startup.
4. Instruções de operação
Follow these steps to operate your EXCEL Tankless Gas Water Heater.
Inicialização inicial:
- Ensure all water and gas connections are properly made and leak-free.
- Abra a válvula principal de fornecimento de gás.
- Open a hot water faucet in your system. The unit will detect water flow (as low as 2 PSI) and automatically ignite.
- Allow water to run for a few moments to purge any air from the lines.
Operação diária:
- To get hot water, simply open any hot water faucet connected to the unit. The heater will automatically ignite and begin heating water as it flows through.
- The unit is designed for a temperature rise of approximately 45°F, delivering 1.6 Gallons Per Minute (GPM).
- While suitable for multiple points of use, it is recommended to use no more than one point of use at a time for optimal performance.
- For incoming cold water temperatures below 50°F (down to 40°F), you may need to reduce the water flow rate using the control knob to achieve desired hot water temperature.
- The unit features a 20-minute safety shutoff. If hot water is continuously drawn for more than 20 minutes, the unit will automatically shut off. To restart, close the hot water faucet and then reopen it.
5. Manutenção
A manutenção regular garante a longevidade e o funcionamento eficiente do seu aquecedor de água.
Verificações de rotina:
- Substituição da bateria: Replace the two D-size batteries annually, or if the ignition becomes inconsistent. Use high-quality alkaline batteries.
- Inspeção de vazamento: Periodically check all water and gas connections for leaks. For gas leaks, use a soapy water solution.
- Limpeza externa: Limpe o exterior da unidade com um pano macio eamp pano. Não use produtos de limpeza abrasivos ou solventes.
Winterization (Freezing Protection):
If the unit will be exposed to freezing temperatures, it is crucial to drain all water from the system to prevent damage.
- Desligue o fornecimento de gás para a unidade.
- Feche o registro de água fria que alimenta o aparelho.
- Open a hot water faucet in your system to relieve pressure.
- Localize o Winter Drain valve at the bottom of the unit (refer to Figure 3.2). Open this valve to drain the water from the heat exchanger.
- Once drained, close the drain valve.

Figura 5.1: interno view of the copper heat exchanger, which should be drained to prevent freezing damage.
6. Solução De Problemas
This section provides solutions to common issues you might encounter with your water heater.
| Problema | Possível causa | Solução |
|---|---|---|
| Sem água quente / O aparelho não liga | No water flow or insufficient water pressure | Ensure water supply is on and water pressure is at least 2 PSI. Check for kinks in water lines. |
| Baterias descarregadas ou fracas | Replace both D-size batteries with new alkaline batteries. | |
| Sem fornecimento de gás | Ensure gas tank is not empty and gas supply valve is fully open. | |
| ODS or 20-minute safety shutoff activated | Ensure adequate ventilation. If unit ran for 20 minutes, close and reopen hot water faucet to reset. | |
| A água não está quente o suficiente | High water flow rate for incoming temperature | Reduce water flow rate using the control knob on the unit. |
| Baixa temperatura da água de entrada | The unit adds approximately 45°F to incoming water. If incoming water is very cold, the output temperature will be lower. Reduce flow rate. | |
| Gas or water leaks | Conexões soltas ou componentes danificados | Tighten all connections. If leaks persist, contact a qualified professional for inspection and repair. Do not attempt to repair gas leaks yourself. |
Se o problema persistir após tentar essas soluções, entre em contato com um técnico qualificado.
7. Especificações
Technical specifications for the EXCEL Tankless Gas Water Heater.

Figura 7.1: Rótulo do produto com especificações detalhadas.
| Especificação | Valor |
|---|---|
| Marca | EXCEL |
| Número do modelo | 850020757060 |
| Dimensões do produto (L x P x A) | 12.8" x 8" x 18.75" (aprox.) |
| Peso do item | 8.6 libras |
| Tipo de combustível | Propano (GLP) |
| Volumetage | 3 Volts (para ignição) |
| Pilhas necessárias | 2 pilhas tamanho D |
| Taxa de fluxo máxima | 1.6 galões por minuto (GPM) |
| Saída de calor | 40,000 Unidades Térmicas Britânicas (BTU) |
| Aumento da temperatura | Adds approximately 45°F to cold water |
| Minimum Water Pressure Startup | 2 PSI |
| Pressão máxima de operação | 120 PSI |
| Características de segurança | Oxygen Depletion Safety (ODS) shutoff, 20-minute safety shutoff |
| Tipo de montagem | Montagem na parede |
| Componentes incluídos | 2 Size D Batteries, Exhaust diffuser Plate, LPG Brass Fitting for ⅜" Flare connection |
8. Garantia e Suporte
For warranty information and technical support, please refer to the documentation included with your purchase or contact the seller directly. The seller for this product is typically Energy-Store.