1. Produto acabadoview
The DB Electrical Smart Isolator Switch 48530-BX is designed to efficiently manage power distribution in vehicles with multiple battery banks. This device allows the alternator to charge all connected batteries while preventing the battery with a higher charge from draining into a lower charged battery. It ensures optimal power management and extends battery life by isolating battery banks when necessary.
This smart isolator is a direct replacement for Cole Hersee 48530BX and Navistar ZN48530 models, ensuring compatibility and reliable performance.

Image showing the DB Electrical Smart Isolator Switch 48530-BX with its main body, terminals, and connecting wires. The blue label on the device indicates 'Cole Hersee Co. 48530 SERIES SMART ISOLATOR' and shows a basic wiring diagram.
2. Especificações
| Recurso | Detalhe |
|---|---|
| Vol de entradatage | 12 VCC |
| Volume de entrada baixotage | 9 V |
| Vol de entrada altatage | 16 V |
| Separation Voltage | 12.7 V |
| Volume de conexãotage | 13.2 V |
| Ampidade | 200 Amps |
| Número de entradas | 1 |
| Number of Battery Banks | 2 |
| Modo de operação | Automático |
| Tipo de contato | Normalmente aberto |
| Tipo de conector | Terminais de parafuso |
| Tipo de Circuito | 2 vias |
| Material de contato | Cobre |
| Avaliação de proteção internacional | IP66 |
| Conformidade | SAE J1455 & J1113 |
| Dimensões do produto (C x L x A) | 5.6 x 4.3 x 3.6 polegadas |
| Peso | 1.2 libras |
Note: Works with all types of alternators. No efficiency loss due to diodes. Allows bi-directional charging from alternator or from shore power. Reduces load on charging system.
3. Configuração e instalação
Proper installation is crucial for the optimal performance and longevity of your Smart Isolator Switch. It is highly recommended that installation be performed by a qualified professional.
3.1 Lista de verificação de pré-instalação
- Verify that the part fits your specific vehicle and application before beginning installation.
- Ensure all power sources are disconnected from the vehicle's electrical system to prevent accidental short circuits or injury.
- Gather all necessary tools, including wrenches, wire strippers, crimpers, and appropriate gauge wiring.
3.2 Instruções de Fiação
The Smart Isolator is designed to connect your primary (main) battery, auxiliary battery, and the vehicle's charging system (alternator). Refer to the wiring diagram on the product label and consult your vehicle's specific wiring schematics for detailed connections.
- Montagem: Securely mount the isolator in a dry, protected location away from excessive heat or vibration. Ensure adequate ventilation.
- Main Battery Connection: Connect the main battery terminal of the isolator to your primary starting battery.
- Conexão da bateria auxiliar: Connect the auxiliary battery terminal of the isolator to your secondary (auxiliary) battery bank.
- Alternator/Charging System Connection: Connect the appropriate terminal on the isolator to the vehicle's alternator or charging system output.
- Conexão à terra: Ensure a solid ground connection for the isolator to the vehicle chassis.
- Control Wires: Connect any necessary control wires (e.g., ignition, boost, status) as per the specific wiring diagram for your application.
Use appropriate gauge wiring for all connections to handle the 200 Amps rating and ensure secure, corrosion-free terminals.
4. Operação
The DB Electrical Smart Isolator operates automatically to manage power flow between your battery banks. Its intelligent design ensures that your auxiliary battery is charged when the engine is running, without drawing power from your main starting battery when the engine is off.
- Carregamento: When the vehicle's charging system (alternator) is active and the voltage reaches the connection threshold (13.2V), the isolator connects the battery banks, allowing both to charge simultaneously.
- Isolamento: When the engine is off or the voltage drops below the separation threshold (12.7V), the isolator separates the battery banks. This prevents accessories connected to the auxiliary battery from draining the main starting battery, ensuring you always have enough power to start your vehicle.
- Bi-Directional Charging: The isolator supports bi-directional charging, meaning it can also facilitate charging of both battery banks from an external shore power charger, if connected to the appropriate terminals.
The automatic operation requires no manual intervention, providing a seamless and reliable power management solution.
5. Manutenção
To ensure the long-term reliability and performance of your Smart Isolator Switch, periodic maintenance is recommended:
- Inspecionar conexões: Regularly check all electrical connections to the isolator for tightness and corrosion. Loose or corroded connections can lead to poor performance or failure.
- Limpeza: Keep the isolator unit clean and free from dirt, dust, and moisture. Use a dry cloth to wipe down the exterior.
- Inspeção de fiação: Periodically inspect the wiring connected to the isolator for any signs of wear, fraying, or damage. Replace damaged wiring immediately.
- Proteção Ambiental: While rated IP66 for protection against dust and strong water jets, avoid submerging the unit or exposing it to extreme environmental conditions beyond its rating.
No internal user-serviceable parts. Do not attempt to open or repair the unit yourself, especially if it is under warranty.
6. Solução De Problemas
If you experience issues with your Smart Isolator Switch, consider the following troubleshooting steps:
- No Charging of Auxiliary Battery:
- Verifique se todas as conexões da fiação estão soltas ou corroídas.
- Verify that the main battery is fully charged and the alternator is functioning correctly (outputting sufficient voltage)
- Verifique o volume do veículotage reaches the connection threshold (13.2V) when the engine is running.
- Main Battery Draining:
- Confirm that the isolator is properly separating the batteries when the engine is off (voltage abaixo de 12.7 V).
- Check for any parasitic draws on the main battery not related to the isolator.
- Superaquecimento:
- Ensure the isolator is mounted in a location with adequate airflow.
- Verify that the current draw does not exceed the 200 Amp avaliação.
- Verifique se há conexões soltas, que podem causar resistência e aquecimento.
If troubleshooting steps do not resolve the issue, contact DB Electrical customer support for further assistance. Do not attempt to repair the unit yourself, especially if it is under warranty.
7. Garantia e Suporte
DB Electrical stands behind the quality of its products. This Smart Isolator Switch is covered by a Garantia de 1 ano a partir da data da compra.
- Cobertura da garantia: The warranty protects against defects in materials and workmanship under normal use.
- Processo de reivindicação: In the rare event that the product does not function flawlessly after installation, please contact DB Electrical customer support. We will take every step to assist you and arrange for a replacement if necessary, within one year of your order.
- Exclusões: The warranty does not cover damage resulting from improper installation, misuse, abuse, unauthorized modifications, or natural disasters. Attempting to repair the tool yourself will void the warranty.
For technical support, warranty claims, or any other inquiries, please refer to the contact information provided with your purchase or visit the official DB Electrical website.