SINOTIMER TM619-3 24V

SINOTIMER TM619 Digital LCD Power Timer Switch User Manual

Model: TM619-3 24V

1. Introdução

Frente view of the SINOTIMER TM619 Digital LCD Power Timer Switch

Figura 1: Frente view of the TM619 Digital Timer Switch, showing the LCD display and control buttons.

The SINOTIMER TM619 is a versatile digital LCD power timer switch designed for automatically controlling various electrical equipment. It allows for precise scheduling of ON/OFF cycles over a 7-day period. This device is ideal for applications such as controlling streetlights, neon signs, lamps, water heaters, air conditioners, billboards, electric cookers, boosters, sprayers, bottlers, preheaters, agriculture facilities, and broadcasting equipment.

Equipped with a built-in battery, the TM619 retains programmed settings even during power failures. Its design incorporates a low-consumption, high-accuracy CMOS chip, ensuring strong anti-jamming capabilities and reliable performance. The timer is simple to set up and conforms to IEC 60367 and CE certifications.

2. Principais características

3. Especificações

ParâmetroValor
ModeloTM619-3
Fonte de energia24 VCC
Capacidade de carga16A, 3500W máx.
MostrarLCD
Intervalo do temporizador1 minuto a 168 horas
Consumo de energia4.5VA
Programas16 ON / OFF settings per day or week
Histerese2 seconds / day (at 25°C)
Intervalo mínimo1 minuto
Contato de comutação1 chave de comutação (1NA+1NF)
Memória de apagão60 Days (with built-in battery)
Dimensões (Pacote)4.69 x 4.57 x 2.01 polegadas
Peso do item109 gramas (3.84 onças)
CorGray, White, Black

4. Instalação

4.1 Diagrama de fiação

Voltar view of the SINOTIMER TM619 showing wiring terminals and contact rating

Figura 2: Voltar view of the TM619 with wiring terminals and specifications.

The TM619 timer switch features 5 terminals for connection. Refer to the diagram on the back of the unit and Figure 2 for proper wiring. Ensure all connections are secure and comply with local electrical codes.

The output contacts are rated for 16A at 250VAC (50/60Hz) for resistive loads, and 1HP at 125VAC, 2HP at 250VAC for inductive loads. For DC loads, it supports 20A at 30VDC.

4.2 Montagem

The TM619 is designed for panel mounting. It features mounting holes on its casing for secure attachment to a control panel or enclosure. Ensure adequate ventilation around the unit to prevent overheating.

5. Configuração e Programação

Before programming, ensure the timer is powered. The built-in battery will charge when the unit is powered, maintaining settings during power interruptions.

Angulado view of the SINOTIMER TM619 showing the side profile e botões

Figura 3: Angulado view of the TM619, highlighting the compact design and button layout.

5.1 Configurar a hora e o dia atuais

  1. Pressione e segure o RELÓGIO botão.
  2. Enquanto segura RELÓGIO, imprensa DIA to set the current day of the week (Mo, Tu, We, Th, Fr, Sa, Su).
  3. Enquanto segura RELÓGIO, imprensa HORA Para definir a hora atual (0-23).
  4. Enquanto segura RELÓGIO, imprensa MÍNIMO Para definir o minuto atual (0-59).
  5. Solte o RELÓGIO button. The time and day are now set.

5.2 Programação dos horários de LIGAR/DESLIGAR

The TM619 allows for up to 16 ON/OFF programs. Each program consists of an ON time and an OFF time.

  1. Pressione o CRONÔMETRO pressione o botão uma vez. O visor mostrará "1 LIGADO".
  2. Imprensa DIA to select the day(s) for this ON program. You can choose a single day, specific days (e.g., Mo-Fr), or all 7 days.
  3. Imprensa HORA para definir a hora LIGADA desejada.
  4. Imprensa MÍNIMO para definir o minuto LIGADO desejado.
  5. Imprensa CRONÔMETRO novamente. O visor mostrará "1 OFF".
  6. Repeat steps 2-4 to set the OFF day(s), hour, and minute for the first program.
  7. Imprensa CRONÔMETRO to advance to the next program ("2 ON", "2 OFF", etc.) and repeat the process for up to 16 programs.
  8. Após configurar todos os programas desejados, pressione o RELÓGIO Botão para sair do modo de programação e retornar à exibição da hora atual.

Note: If you need to clear a specific program, navigate to that program (e.g., "3 ON") and press the MANUAL button. This will clear the settings for that ON/OFF pair.

5.3 Substituição Manual

O MANUAL Este botão permite que você altere as configurações programadas temporariamente ou permanentemente.

5.4 Reiniciando o temporizador

To clear all settings and reset the timer to its factory defaults, locate the small reset button (often recessed) on the front of the unit. Use a pointed object (like a pen tip) to press this button. This will clear all programmed times and reset the clock.

6. Operação

Once programmed and set to AUTO mode, the SINOTIMER TM619 will automatically switch the connected electrical equipment ON and OFF according to the precise times and days you have set. The LCD display will show the current time and day, along with the current status (ON, AUTO, OFF).

The timer's internal clock is highly accurate, with a hysteresis of 2 seconds per day at 25°C, ensuring reliable long-term operation. The built-in battery provides a black-out memory of up to 60 days, meaning your programs will be retained even during extended power outage.

7. Manutenção

8. Solução De Problemas

ProblemaPossível causaSolução
Timer display is blank or dim.No power supply to the timer; internal battery fully discharged.Check power input (24VDC) to terminals 1 & 2. Allow time for the internal battery to charge (several hours) after power is restored.
O temporizador não liga/desliga nos horários programados.1. Timer is not in AUTO mode.
2. Incorrect programming.
3. Overlapping programs.
4. Problema de fiação.
1. Pressione MANUAL até que "AUTO" seja exibido.
2. Ref.view and re-enter programs carefully, ensuring ON/OFF times and days are correct.
3. Adjust programs to avoid conflicts.
4. Verify output wiring (Terminals 3, 4, 5) and load connections.
Time on display is incorrect.Hora incorreta; bateria interna fraca.Reset and re-set the current time and day (Section 5.1). Ensure continuous power supply for battery charging.
Não é possível entrar no modo de programação.Timer is locked or in an unusual state.Press the reset button with a pointed object to clear all settings and then try again.
Output is always ON or always OFF.Timer is in ON or OFF manual override mode.Imprensa MANUAL até que "AUTO" seja exibido.

9. Garantia e Suporte

SINOTIMER products are manufactured to high-quality standards. For specific warranty information and technical support, please refer to the documentation provided with your purchase or contact SINOTIMER customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

For further assistance, you may visit the official SINOTIMER store or contact their support channels. Ensure you have your model number (TM619-3 24V) ready when seeking support.

Documentos relacionados - TM619-3 24V

Préview Temporizador programável semanal Sinotimer TM-616 - Especificações e operação
Informações detalhadas sobre o temporizador programável semanal Sinotimer TM-616, incluindo especificações, funções dos botões, dimensões, diagramas de fiação e linha de produtos. Possui programação para 7 dias e capacidade de comutação de 30 A.
Préview Interruptor de temporizador digital LCD HD da série SINOTIMER TM928 - Manual do usuário e especificações
Guia completo para os interruptores de temporizador digital da série SINOTIMER TM928, abrangendo recursos, especificações, configuração e fiação para modelos como TM919, TM920, TM928, TM928S, TM928R e TM929.
Préview Manual de instruções do temporizador eletrônico Sinotimer TM-618 de 7 dias
Manual de instruções completo para o temporizador eletrônico Sinotimer TM-618 de 7 dias, detalhando recursos, programação, operação manual e avisos de segurança.
Préview Temporizador digital SINOTIMER TM-630A/TM-630S: características e especificações
Especificações técnicas detalhadas e recursos para os temporizadores digitais programáveis ​​SINOTIMER TM-630A e TM-630S, incluindo fonte de alimentação, intervalo de tempo, dimensões e fiação.
Préview Manual do usuário do interruptor de tempo programável 3 em 1 da série SINOTIMER TM920
Manual do usuário completo para o temporizador programável 3 em 1 da série SINOTIMER TM920, com programação de 7 dias, funções de pulso e contagem regressiva. Aprenda a definir data, hora, modos de controle e configurações de feriados.
Préview Interruptor de tempo digital SINOTIMER TM-610 para trilho DIN - Manual do usuário e especificações
Especificações detalhadas, diagramas de fiação e instruções de operação para o interruptor de tempo digital SINOTIMER TM-610, projetado para montagem em trilho DIN.