1. Introdução
The Hantek DSO2D10 is a 2-channel digital storage oscilloscope featuring a 100MHz bandwidth, 1GSa/s real-time sample rate, and 8M memory depth. This model also integrates a 1-channel, 25MHz arbitrary waveform generator, making it a versatile tool for electronic testing and development. This manual provides essential information for the safe and effective operation of your device, covering setup, basic operation, advanced features, maintenance, and troubleshooting.
2. Informações de segurança
Please read the following safety precautions carefully to avoid personal injury and prevent damage to this product or any products connected to it. This oscilloscope is designed for use by qualified personnel only.
- Fonte de energia: Connect the oscilloscope only to a power source that provides the specified voltage gama.
- Aterramento: Certifique-se de que o osciloscópio esteja devidamente aterrado para evitar choque elétrico.
- Segurança da Sonda: Use only probes supplied with the instrument or recommended by Hantek. Observe the voltage ratings of the probes.
- Condições ambientais: Do not operate the oscilloscope in wet or damp conditions. Avoid operating in explosive atmospheres.
- Ventilação: Garanta ventilação adequada para evitar superaquecimento. Não bloqueie as aberturas de ventilação.
- Manutenção: Do not attempt to service the instrument unless you are qualified to do so. Refer all servicing to qualified service personnel.
Aviso: Vol perigosotage inside. Do not remove the cover unless by specified personnel.
3. Conteúdo da embalagem
Verifique se todos os itens listados abaixo estão incluídos em seu pacote. Caso algum item esteja faltando ou danificado, entre em contato com seu revendedor.
- Hantek DSO2D10 Digital Storage Oscilloscope Unit
- 100MHz Oscilloscope Probes (2 units, typically 10X/100X switchable)
- BNC to Alligator Clip Cables (2 units)
- Cabo USB
- Cabo de alimentação
- User Manual (Digital version often available online)
Figure 3.1: Hantek DSO2D10 Oscilloscope with all standard accessories.
Figure 3.2: Close-up of the included 100X and 10X probes, BNC cables, USB cable, and power cord.
4. Produto acabadoview
4.1 Painel Frontal
The front panel features the display, control knobs, function buttons, and input connectors for channels 1 and 2, as well as the external trigger/waveform generator output.
Figura 4.1: Frente view of the Hantek DSO2D10 Oscilloscope.
Figura 4.2: Detalhado view of the front panel controls, including vertical, horizontal, and trigger sections.
- Mostrar: High-resolution TFT LCD for waveform visualization.
- Botões de função (F1-F6): Context-sensitive menu options.
- Controles verticais: VOLTS/DIV knobs and POSITION knobs for each channel (CH1, CH2).
- Controles horizontais: SEC/DIV knob and POSITION knob for time base adjustment.
- Controles de gatilho: LEVEL knob, MODE button, and related settings for stable waveform capture.
- Measurement/Utility Buttons: Access to automatic measurements, cursors, save/recall, and other utilities.
- Entradas de canal (CH1, CH2): BNC connectors for probe connection.
- EXT TRIG/GEN OUT: BNC connector for external trigger input or waveform generator output.
4.2 Painel traseiro
The rear panel includes the power input, USB host port, and ventilation.
Figura 4.3: Traseira view of the Hantek DSO2D10 Oscilloscope, showing power input and USB port.
- Entrada de energia: AC power connector.
- Porta de host USB: For connecting USB storage devices to save waveforms or settings.
- Grades de ventilação: Essencial para a dissipação de calor.
5. Configuração
5.1 Conexão de Energia
- Certifique-se de que a chave de alimentação do osciloscópio esteja na posição DESLIGADO.
- Conecte o cabo de alimentação fornecido à entrada de alimentação CA no painel traseiro do osciloscópio.
- Conecte a outra extremidade do cabo de alimentação a uma tomada elétrica CA aterrada.
5.2 Conexão e Compensação da Sonda
Oscilloscope probes are crucial for accurate measurements. Proper connection and compensation are necessary.
- Connect the BNC end of the probe to either the CH1 or CH2 input connector on the front panel.
- Attach the probe ground clip to the oscilloscope's ground terminal or a known ground point in your circuit.
- Compensação da sonda: Most probes have a compensation adjustment. To compensate a probe:
- Connect the probe tip to the probe compensation test point (usually a square wave output on the front panel).
- Adjust the compensation trimmer on the probe until the square wave displayed on the screen has flat tops and bottoms, without overshoot or undershoot.
6. Instruções de operação
6.1 Ligar/Desligar
Press the power button on the front panel to turn the oscilloscope ON or OFF.
6.2 Basic Waveform Display
- Connect a compensated probe to CH1.
- Connect the probe tip to the signal you wish to measure.
- Pressione o AJUSTE AUTOMÁTICO button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings to display a stable waveform.
- Alternatively, manually adjust the VOLTS / DIV knob for vertical scaling, SEG/DIV knob for horizontal scaling, and the TRIGGER LEVEL knob for trigger point adjustment.
Figura 6.1: Example of a sine wave displayed with automatic measurements.
6.3 controles verticais
- VOLTS/DIV: Adjusts the vertical scale (voltage per division) for the selected channel.
- POSIÇÃO: Moves the waveform vertically on the screen.
- CH1/CH2 MENU: Accesses channel-specific settings like coupling (AC/DC/GND), bandwidth limit, and probe attenuation.
6.4 controles horizontais
- SEC/DIV: Adjusts the horizontal scale (time per division).
- POSIÇÃO: Moves the waveform horizontally on the screen.
- HORIZ MENU: Accesses horizontal settings, including zoom and main/window time base.
6.5 Trigger System
O sistema de disparo estabiliza formas de onda repetitivas e captura eventos de disparo único.
- NÍVEL: Ajusta o voltage level at which the trigger occurs.
- MODO: Selects trigger modes (Auto, Normal, Single).
- TRIGGER MENU: Provides access to advanced trigger settings, including edge, pulse, video, slope, and serial protocol triggers.
Figure 6.2: Displaying two synchronized sine waves on CH1 and CH2.
7. Recursos avançados
7.1 Waveform Generator (AWG)
The DSO2D10 includes a 1-channel, 25MHz arbitrary waveform generator. This allows you to output various standard waveforms (sine, square, ramp, pulse) and custom arbitrary waveforms.
- Conecte um cabo BNC da EXT TRIG/GEN OUT port to your circuit.
- Pressione o WAVE GEN botão para acessar o menu do gerador de formas de onda.
- Select the desired waveform type, frequency, amplitude e deslocamento.
- Enable the output to generate the waveform.
Figura 7.1: Example of a generated sine wave displayed on the oscilloscope.
7.2 Automatic Measurements
The oscilloscope supports 32 types of automatic measurements, providing quick and accurate analysis of waveform parameters.
- Pressione o MEDIR button to open the measurement menu.
- Select the desired measurement parameters (e.g., Vpp, Vmax, Freq, Period, Rise Time, Fall Time).
- The results will be displayed on the screen.
Figure 7.2: Multiple automatic measurements displayed on the screen.
7.3 Digital Voltmeter (DVM) and Frequency Counter
The DSO2D10 includes a 3-digit digital voltmeter and a 6-digit hardware frequency counter for precise voltage leituras de frequência.
- Access these functions through the UTILIDADE menu.
- Select the desired measurement type (e.g., DC RMS, AC RMS, Peak-to-Peak).
7.4 Serial Protocol Decoding
The oscilloscope supports decoding of various serial protocols, which is useful for debugging embedded systems.
- Pressione o DECODIFICAR button to access the serial decoding menu.
- Select the protocol (e.g., RS232, I2C, SPI) and configure the relevant parameters.
7.5 Save/Recall Settings and Waveforms
You can save instrument settings and captured waveforms to internal memory or a USB flash drive.
- Imprensa SAVE/RECALL to manage saved data.
- Usar SAVE TO USB to store data on an external USB device.
8. Manutenção
8.1 Limpeza
- Disconnect the oscilloscope from all power sources and test circuits before cleaning.
- Use um pano macioampened with a mild detergent solution to clean the exterior surfaces. Do not use abrasive cleaners or solvents.
- Avoid spraying liquids directly onto the instrument.
8.2 Armazenamento
When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures.
9. Solução De Problemas
This section provides solutions to common issues you might encounter. If the problem persists, contact Hantek support.
| Problema | Possível causa | Solução |
|---|---|---|
| Sem exibição após ligar | Power cord not connected; Power switch off; Faulty power outlet. | Check power cord connection; Ensure power switch is ON; Test power outlet. |
| Nenhuma forma de onda exibida | Probe not connected; Incorrect vertical/horizontal settings; Trigger not set correctly; No input signal. | Connect probe; Press AUTO SET; Adjust VOLTS/DIV, SEC/DIV, and TRIGGER LEVEL; Verify signal source. |
| forma de onda instável | Incorrect trigger level or mode; Noisy signal. | Adjust TRIGGER LEVEL; Change TRIGGER MODE (e.g., to Normal for single-shot); Check signal integrity. |
| Waveform generator output not working | Output disabled; Incorrect settings; Cable issue. | Ensure output is enabled in WAVE GEN menu; Verify frequency/amplitude settings; Check BNC cable connection. |
10. Especificações
10.1 Especificações Gerais
- Fabricante: Hantek
- Número do modelo: TXD-a221
- Peso do item: 1.91 quilos
- Dimensões do produto: 11 x 32 x 15 cm
- Estilo: 100MHz 2CH+1CH (Oscilloscope + Waveform Generator)
- Pilhas incluídas: Não
- Pilhas necessárias: Não
10.2 Especificações do Osciloscópio
- Largura de banda: 100MHz
- Canais: 2 (canal duplo)
- S em tempo realample Taxa: 1GSa/s
- Profundidade de memória: 8 milhão de pontos
- Resolução vertical: 8 bits
- Medições Automáticas: 32 tipos
- Modos de gatilho: 14 types (Edge, Pulse, Video, Slope, etc.)
- Digital Voltmeter (DVM): 3 dígitos
- Hardware Frequency Counter: 6 dígitos
10.3 Waveform Generator Specifications
- Canais: 1
- Largura de banda: 25MHz
- Arbitrary Waveform Length: 4K points
- Tipos de saída: Seno, Quadrado, Ramp, Pulse, Arbitrary
10.4 Probe Specifications (P4100 Exampe)
Figura 10.1: Example specifications for a P4100 oscilloscope probe.
| Parâmetro | Valor | Parâmetro | Valor |
|---|---|---|---|
| Taxa de atenuação | X100 | Input Resistance (MΩ) | 100 |
| Capacitância de entrada (pF) | 6 | Faixa de compensação (pF) | 10-35 |
| Largura de banda (MHz) | 100 | Tempo de resposta (ns) | 3.5 |
| Vol de Trabalhotage (Vp.p) | 2000 | Peso líquido (g) | 60 |
| Comprimento do cabo (cm) | 110 | Temperatura de operação (°C) | -10 ~ +50 |
| Non-operating Temperature (°C) | -20 ~ +60 | Umidade | 85% de umidade relativa |
11. Garantia e Suporte
Hantek products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official Hantek webou entre em contato com seu distribuidor local. Guarde o comprovante de compra como prova para eventuais solicitações de garantia.