This manual provides instructions for the installation, operation, and maintenance of the Vimar 02970 thermostat. This device is designed for controlling heating and cooling systems with ON/OFF functionality, featuring a control knob, relay output, and an LED backlight with brightness adjustment. It is compatible with Vimar Eikon, Arké, or Plana frames.
2. Informações de segurança
A instalação deve ser realizada por pessoal qualificado, em conformidade com as normas e regulamentos elétricos locais.
Disconnect power at the main circuit breaker before installation or maintenance to prevent electric shock.
Não exponha o dispositivo à umidade ou temperaturas extremas.
Ensure proper wiring connections to avoid damage to the thermostat or connected systems.
3. Produto acabadoview
The Vimar 02970 thermostat offers intuitive control over your climate system. Key features include:
Botão de controle: For easy temperature adjustment.
Retroiluminação LED: Adjustable brightness for clear visibility.
Modos de aquecimento e resfriamento: Supports both heating and cooling systems with ON/OFF control.
Friendly Programming: Designed for straightforward setup and use.
Atalhos de teclado: Allows for quick interaction with the device.

Figura 1: Frente view of the Vimar 02970 thermostat, showing the central display, control knob, and surrounding icons for temperature units, light, and mode selection.
4. Configuração e instalação
4.1 Desembalagem
Carefully remove the thermostat and any included components from the packaging. Verify that all parts are present.
4.2 Montagem
The Vimar 02970 thermostat is designed to be integrated into Eikon, Arké, or Plana frames. Ensure the chosen frame is compatible.

Figure 2: The Vimar 02970 thermostat integrated into a wall frame, demonstrating its flush-mount appearance.
4.3 fios
Before wiring, ensure the main power supply to the circuit is disconnected.
Identify the power supply wires (Live, Neutral) and the heating/cooling system control wires (Common, Normally Open, Normally Closed).
Connect the Live (L) and Neutral (N) wires to the corresponding terminals on the thermostat. The thermostat operates on 100-240V~, 50/60Hz.
Connect the heating/cooling system control wires to the C (Common), NO (Normally Open), and NC (Normally Closed) relay output terminals as required by your system.
Ensure all connections are secure. The terminals are designed for wires up to 6 mm².

Figura 3: Traseira view of the Vimar 02970 thermostat, showing the screw terminals for electrical connections (L, N, C, NO, NC).

Figura 4: Lateral view of the Vimar 02970 thermostat, illustrating the depth and the wiring terminals with specifications (100-240V~, 5(2)A, 1B.U, -T40).
4.4 Inicialização
After wiring, restore power at the main circuit breaker. The thermostat display should illuminate.
5. Instruções de operação
5.1 Ligar/Desligar
Pressione o ícone de energia (⏻) located on the bottom left of the thermostat to turn the device on or off.
5.2 Ajuste da temperatura
Rotate the central control knob clockwise to increase the set temperature and counter-clockwise to decrease it. The current set temperature will be displayed on the LED screen.

Figure 5: A hand rotating the central control knob of the Vimar 02970 thermostat to adjust the temperature setting.
5.3 Changing Mode (Heating/Cooling)
The thermostat supports both heating and cooling modes. The mode can typically be switched using a dedicated button or a combination of button presses. Refer to the on-screen icons for current mode indication (e.g., snowflake for cooling, sun for heating).
5.4 Backlight Brightness Adjustment
The LED backlight brightness can be adjusted. Consult the Vimar website for specific instructions on accessing this setting, as it may involve keyboard shortcuts.
5.5 Programming (If Applicable)
The thermostat features "Friendly Programming." For detailed instructions on setting schedules or advanced programming options, refer to the comprehensive tutorials available on the official Vimar website.
6. Manutenção
Limpeza: Wipe the thermostat surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.
Inspeção: Periodically check for any loose connections or signs of damage. If damage is observed, disconnect power and contact a qualified technician.
7. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| Thermostat display is off. | Sem fonte de alimentação. | Check the main circuit breaker. Ensure wiring connections are secure. |
| Sistema (aquecimento/arrefecimento) não responde. | Incorrect wiring; thermostat in wrong mode; set temperature not reached. | Verify wiring connections. Ensure the thermostat is in the correct mode (heating/cooling). Adjust the set temperature to be above/below the ambient temperature to trigger the system. |
| A leitura da temperatura parece imprecisa. | A localização do termostato é afetada por correntes de ar ou fontes de calor. | Ensure the thermostat is not installed near windows, doors, or direct heat/cold sources. |
8. Especificações
| Recurso | Detalhe |
|---|---|
| Número do modelo | 02970 |
| Marca | VIMAR |
| Volumetage | 100-240V~ |
| Freqüência | 50/60Hz |
| Saída de relé | 5(2)A, 1B.U |
| Temperatura de operação | -T40 (Specific range not provided, consult Vimar documentation) |
| Peso do item | 70 g |
| Dimensões do produto | 4.15 x 4.48 x 4.9 cm (42D x 45W x 49H millimeters) |
| Tipo de controlador | Botão mecânico |
| Características especiais | Lighted (LED Backlight) |
| Conectividade | Com fio |
| Molduras Compatíveis | Eikon, Arké, or Plana |

Figure 6: Technical diagram showing the dimensions of the Vimar 02970 thermostat (41.7mm depth, 44.8mm width, 49mm height).
9. Garantia e Suporte
For warranty information, technical support, or additional tutorials, please visit the official Vimar website or contact your local Vimar distributor. The Vimar website provides comprehensive instructions and tutorials for programming and advanced features.
Vimar Website: www.vimar.com