Produto acimaview
The VECTOR SS6LV is a compact and powerful 1200 peak amp lithium jump starter designed to instantly start cars and trucks with up to 8-cylinder engines. Beyond its primary function, it serves as a versatile portable power bank, featuring USB-A (2.1 Amps) and USB-C (3.1 Amps) ports for charging various electronic devices. It also includes an integrated LED work light for convenience in low-light conditions. The unit is equipped with a Smart Controller for safe operation, providing reverse polarity protection, and comes with heavy-duty powder-coated clamps.

Image: The VECTOR SS6LV jump starter with its attached heavy-duty clamps, mostrarcasingraças ao seu design compacto.
O que está na caixa
Ao abrir a embalagem, você encontrará os seguintes componentes:
- VECTOR SS6LV Lithium Jump Starter Unit
- Smart Controller with Heavy Duty Powder Coated Clamps
- Adaptador de carregamento CA
- DC (Car) Charging Adapter
- Cabo de carregamento USB

Image: All components included in the VECTOR SS6LV product box.
Características do produto
- Auxiliar de partida: Delivers 1200 peak amps, capable of jump starting vehicles with up to 8-cylinder engines.
- Carregador USB: Equipped with USB-A (2.1 Amps) and USB-C (3.1 Amps) ports to charge and power various electronic devices such as phones, tablets, and laptops.
- Bateria de lítio recarregável: Internal lithium-ion battery can be recharged using the included AC, DC, or USB adapters.
- Operação segura: Features an Engine Start Smart Controller with reverse polarity protection, ensuring correct and safe connection of jumper cables.
- Design portátil: Compact and lightweight, making it easy to store and transport for on-the-go power needs.
- Luz de trabalho LED: Integrated bright LED light provides illumination for nighttime or low-light situations.

Imagem: Detalhada view of the VECTOR SS6LV unit with key features labeled.
Configurar
Carregamento inicial
Before first use, fully charge the VECTOR SS6LV unit. It is recommended to fully charge the unit every 3 to 6 months to maintain optimal battery health, even if not in use.
- Connect the USB Charging Cable to the unit's USB-C port.
- Connect the other end of the USB Charging Cable to either the AC Charging Adapter (for wall outlet) or the DC Charging Adapter (for vehicle 12V accessory outlet).
- Plug the chosen adapter into its respective power source. The battery indicator lights on the unit will illuminate to show charging progress.
- Charging is complete when all indicator lights are solid blue.
Connecting for Jump Start
Certifique-se de que a ignição do veículo esteja desligada antes de conectar o cabo auxiliar de partida.
- Locate the battery terminals in your vehicle. The positive terminal is usually marked with a "+" sign and covered by a red cap. The negative terminal is marked with a "-" sign.
- Conecte o cl vermelho (positivo)amp of the Smart Controller to the positive (+) terminal of the vehicle's battery.
- Conecte o cl preto (negativo)amp of the Smart Controller to a clean, unpainted metal part of the vehicle's chassis or engine block, away from the battery and moving parts. Alternatively, connect to the negative (-) terminal of the battery if safe to do so.
- Plug the Smart Controller cable into the "ENGINE START" port on the VECTOR SS6LV unit. The Smart Controller will indicate readiness (e.g., a solid green light).

Image: The jump starter connected to a vehicle battery, ready for use.
Operacional
Dar partida em um veículo
- Ensure the VECTOR SS6LV unit is fully charged and properly connected to the vehicle's battery as described in the "Setup" section.
- Once the Smart Controller indicates readiness (e.g., solid green light), attempt to start the vehicle's engine. Do not crank for more than 5 seconds.
- If the vehicle does not start, wait at least 30 seconds before attempting again. Do not exceed three consecutive jump start attempts.
- Once the vehicle starts, immediately disconnect the Smart Controller from the VECTOR SS6LV unit, then disconnect the black (negative) clamp, seguido pelo cl vermelho (positivo)amp da bateria do veículo.
Usando como um banco de energia
The VECTOR SS6LV can charge various electronic devices.
- Connect your device's USB charging cable to either the USB-A (2.1 Amps) or USB-C (3.1 Amps) port on the side of the VECTOR SS6LV unit.
- Press the power button on the unit to begin charging. The indicator lights will show the remaining battery level.

Image: The jump starter unit actively charging a smartphone.
Usando a luz de trabalho LED
The integrated LED work light provides illumination for various tasks.
- To turn on the LED work light, press and hold the power button for approximately 3 seconds.
- To cycle through light modes (solid, strobe, SOS), briefly press the power button.
- To turn off the LED work light, press and hold the power button again for approximately 3 seconds.

Image: The bright LED work light on the end of the unit.
Manutenção
Recarregando a unidade
To ensure the longevity and readiness of your VECTOR SS6LV, it is crucial to maintain its charge. Recharge the unit after each use, and at least every 3 to 6 months, even if it has not been used. This prevents deep discharge and prolongs battery life.
Armazenar
Store the unit in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it out of reach of children. Ensure the rubber covers for the ports are securely closed to protect against dust and moisture.
Solução de problemas
| Problema | Possível causa | Solução |
|---|---|---|
| A unidade não liga. | A bateria está totalmente descarregada. | Recharge the unit using the provided AC or DC adapters. |
| O veículo não pega com cabos auxiliares. | cl incorretoamp connection; vehicle battery is severely damaged; vehicle engine is too large for the unit's capacity. | Garantir clamps are connected correctly (red to positive, black to chassis/negative). Check Smart Controller indicator. Consult a mechanic if battery is damaged. Confirm vehicle engine size is within the unit's specifications (up to 8-cylinders). |
| Smart Controller shows error. | Reverse polarity connection; short circuit; over-temperature. | Desconectar clamps and re-connect correctly. Ensure clamps do not touch each other. Allow unit to cool down if it has been used extensively. |
| Dispositivos que não carregam via USB. | Unit is off; USB cable is faulty; device is not compatible. | Press the power button to activate USB output. Try a different USB cable. Ensure your device is compatible with standard USB charging. |
Especificações
- Marca: VETOR
- Número do modelo: SS6LV
- Dimensões do produto: 3"P x 1"L x 7"A
- Peso do item: 13.8 onças
- Ampidade: 1200 Amps
- Corrente de saída de pico: 1200 Amps
- Tipo de Bateria: Íon de lítio (1 necessário, incluído)
- Saída USB-A: 2.1 Amps
- Saída USB-C: 3.1 Amps
- Fabricante: Baccus Global LLC
- País de origem: China
Informações de segurança
AVISO: Este produto pode expô-lo a produtos químicos, incluindo chumbo e compostos de chumbo, que são conhecidos pelo estado da Califórnia por causar câncer e defeitos congênitos ou outros danos reprodutivos. Para obter mais informações, vá para www.P65Warnings.ca.gov.
Always refer to the full user manual for complete safety instructions and warnings before operating this device.
Vídeo oficial do produto
Watch this official video from VECTOR to understand the key differences between battery chargers and jump starters, and how the VECTOR SS6LV functions.
Video: "VECTOR - Charger vs Jumper" - This video explains the distinction between battery chargers and jump starters, highlighting the immediate boost provided by a jump starter like the SS6LV.