Xetron STC-1000Pro

Xetron STC-1000Pro Digital Temperature Controller User Manual

Model: STC-1000Pro | Brand: Xetron

1. Introdução

The Xetron STC-1000Pro is a versatile digital temperature controller designed for precise temperature management in various environments. It features dual outlets for simultaneous heating and cooling control, a wide temperature range, and user-friendly operation. This manual provides detailed instructions for setting up, operating, and maintaining your device.

Xetron STC-1000Pro Digital Temperature Controller with power cord, sensor, and dual outlets

Figure 1: Xetron STC-1000Pro Digital Temperature Controller. This image displays the main unit with its digital display, control buttons, power cord, temperature sensor, and the dual-outlet power strip for heating and cooling devices.

Aplicações

The STC-1000Pro is suitable for a wide range of applications requiring accurate temperature control, including:

Various applications of the Xetron STC-1000Pro controller

Figure 2: Common applications for the Xetron STC-1000Pro. This image illustrates the controller's use in home brewing, incubators, aquariums, and flower cultivation, highlighting its versatility.

2. Principais características

Xetron STC-1000Pro maintaining temperature range

Figure 3: Temperature control range of the Xetron STC-1000Pro. This image highlights the controller's ability to maintain temperatures within a desired range of -40 to 230 ℉ using both cooling and heating devices.

Xetron STC-1000Pro large screen display with dimensions

Figure 4: Large screen display of the Xetron STC-1000Pro. The image shows the display dimensions and labels for PV (Present Value), SV (Set Value), Csp (Cooling Start Point), and Hsp (Heating Start Point), indicating ℃/℉ switchability.

Xetron STC-1000Pro visual and audible alerts

Figure 5: Visual and audible alert features. This image illustrates the double alarm and delay protection functionalities of the controller, enhancing safety and monitoring.

Xetron STC-1000Pro safety certifications

Figure 6: Safety and quality certifications. The image highlights the V-0 flame-retardant ABS material and compliance with CE, FCC, and RoHS standards, ensuring product safety.

Xetron STC-1000Pro IP65 waterproof probe

Figure 7: IP65 waterproof features. This image demonstrates the waterproof capability of the temperature probe, which can be immersed in fresh water, and the internal rubber ring for main unit protection.

3. Instruções de configuração

  1. Desembale o dispositivo: Carefully remove the Xetron STC-1000Pro controller and its components from the packaging.
  2. Conecte o sensor: Ensure the temperature sensor is fully inserted into its dedicated port on the side of the controller. A loose connection can lead to "ERR" display.
  3. Posicione o sensor: Place the temperature probe in the environment where temperature monitoring and control are required. Ensure it is not directly exposed to heating or cooling elements to get an accurate reading.
  4. Conecte os dispositivos de aquecimento/resfriamento:
    • Ligue o seu aparelho de aquecimento (por exemplo, aquecedor).amp, heating mat) into the socket labeled "HEATING".
    • Plug your cooling device (e.g., fan, chiller) into the socket labeled "COOLING".

    Importante: The maximum output for each socket is 10A at 240VAC. Do not connect high-power equipment exceeding these limits.

  5. Ligar: Plug the controller's main power cord into a standard 230V AC power outlet. The display will illuminate, showing the current temperature (PV) and other settings.
Xetron STC-1000Pro plug and play setup

Figure 8: Plug-and-play setup of the Xetron STC-1000Pro. This image demonstrates the simplicity of connecting the controller, showing it mounted on a wall next to a terrarium, with heating/cooling devices plugged in.

4. Instruções de operação

The STC-1000Pro features a simple 3-button interface: DEFINIR, PARA CIMA (▲), e PARA BAIXO (▼).

4.1 Exibiçãoview

4.2 Setting the Target Temperature (SV)

  1. Pressione o DEFINIR button once. The SV value will flash.
  2. Use o PARA CIMA (▲) or PARA BAIXO (▼) botões para ajustar a temperatura desejada.
  3. Imprensa DEFINIR again to confirm and save the setting, or wait a few seconds for it to save automatically.

4.3 Advanced Parameter Settings

Para acessar as configurações avançadas, pressione e segure o DEFINIR button for approximately 3 seconds until the display changes to show parameter codes.

Xetron STC-1000Pro parameter setting diagram

Figure 9: Diagram illustrating parameter settings. This image shows the relationship between TS (Temperature Set-point), CD (Cooling Differential), HD (Heating Differential), Csp (Cooling Start Point), and Hsp (Heating Start Point).

Use o PARA CIMA (▲) or PARA BAIXO (▼) buttons to navigate through the parameters. Press DEFINIR to enter a parameter's value, then use PARA CIMA (▲) or PARA BAIXO (▼) ajustar, e DEFINIR novamente para salvar.

Table 1: Advanced Parameters
ParâmetroDescriçãoFaixaPadrão
TS (Temperature Set-point)The desired target temperature (same as SV).-40 a 110 ℃ / -40 a 230 ℉Varia
CD (Cooling Differential)The difference between the cooling start point (Csp) and the set temperature (TS). Cooling activates when PV ≥ TS + CD.0.1 to 30 ℃ / 0.1 to 54 ℉2 ℃ / 3.6 ℉
HD (Heating Differential)The difference between the heating start point (Hsp) and the set temperature (TS). Heating activates when PV ≤ TS - HD.0.1 to 30 ℃ / 0.1 to 54 ℉2 ℃ / 3.6 ℉
PT (Protection Time)Compressor delay protection time (in minutes) for cooling mode only. Prevents frequent compressor cycling.0 a 10 minutos3 minutos
CA (Temperature Calibration)Adjusts the temperature reading to match an external reference thermometer.-10 a 10 ℃ / -18 a 18 ℉0 ℃ / 0 ℉
CF (Unit Switch)Switches between Celsius (℃) and Fahrenheit (℉).C/FC
HA (High Alarm)Sets the upper temperature limit for the alarm.TS to 110 ℃ / TS to 230 ℉110 ℃ / 230 ℉
LA (Low Alarm)Sets the lower temperature limit for the alarm.-40 ℃ / -40 ℉ to TS-40 ℃ / -40 ℉

After adjusting parameters, press and hold DEFINIR again for 3 seconds to exit the advanced settings menu and return to normal operation.

5. Manutenção

6. Solução De Problemas

Tabela 2: Guia de solução de problemas
ProblemaPossível causaSolução
"ERR" displayed on screenTemperature sensor not fully inserted or damaged; temperature exceeds measurement range.Ensure the sensor is fully inserted into its port. If the issue persists, the sensor may be faulty and require replacement. If the temperature is outside the -40 to 110 ℃ range, the controller will display "ERR".
Alarm sounds and bell icon appearsCurrent temperature (PV) has exceeded the set high alarm (HA) or fallen below the low alarm (LA) threshold.Check the environmental conditions. Adjust HA/LA settings if necessary. The controller will disable all outputs in fault alarm mode to protect equipment.
O dispositivo de aquecimento/resfriamento não está ativando.Incorrect temperature settings (TS, CD, HD); compressor delay protection (PT) active; device not properly plugged in; device malfunction.Verify TS, CD, and HD settings. Wait for the PT delay to expire in cooling mode. Ensure devices are securely plugged into the correct outlets. Test heating/cooling devices independently.
Leitura de temperatura imprecisaSensor placement; temperature calibration (CA) offset.Relocate the sensor to a more representative area. Use the CA parameter to calibrate the reading against a known accurate thermometer.

7. Especificações

Tabela 3: Especificações do produto
RecursoDetalhe
Número do modeloXT-STC1000Pro-01US
MarcaXetron
Volumetage230V AC (Note: Product description mentions 230V, specifications mention 110V. User should verify their specific model's voltage requirements.)
Max Corrente de saída10A por soquete
Faixa de controle de temperatura-40 ℃ a 110 ℃ (-40 ℉ a 230 ℉)
Precisão da temperatura±1 ℃ / ±2 ℉
Tipo de exibiçãoOLED
MaterialFlame-retardant ABS Plastic
Dimensões do produto (C x L x A)20 x 15 x 6 cm
Peso400 gramas
Temperatura de operaçãoAté 110 ℃
Componentes incluídos1x Temperature Controller

8. Avisos e precauções de segurança

9. Informações de suporte e contato

For any questions, technical assistance, or customer service inquiries regarding your Xetron STC-1000Pro Digital Temperature Controller, please contact Xetron customer support. We are committed to providing satisfactory customer service.

Consulte a embalagem do produto ou as instruções do revendedor. webPara obter as informações de contato mais atualizadas, acesse o site.

Documentos relacionados - STC-1000Pro

Préview Xetron STC-1000Pro TH Smart Temperature Controller Series User Manual
Comprehensive user manual for the Xetron STC-1000Pro TH Smart Temperature Controller Series, detailing its features, operation, installation, and technical specifications for precise temperature and humidity control.
Préview Manual do usuário do controlador de temperatura inteligente Xetron STC-1000Pro
User manual for the Xetron STC-1000Pro smart digital temperature controller. Details features, operation, installation, and specifications for precise temperature control in applications like homebrewing, aquariums, and incubation.
Préview Manual do Usuário do Controlador de Temperatura Inteligente Elitech STC-1000Pro/STC-1000WiFi | Recursos, Operação, Configuração
Manual do usuário para os controladores de temperatura digitais inteligentes Elitech STC-1000Pro e STC-1000WiFi. Saiba mais sobre recursos, operação, configurações de parâmetros, instalação, solução de problemas e conectividade com o aplicativo para um gerenciamento preciso da temperatura.
Préview Manual do Usuário do Controlador de Temperatura Inteligente Elitech STC-1000Pro/STC-1000WiFi
Manual do usuário para os controladores de temperatura digitais inteligentes Elitech STC-1000Pro e STC-1000WiFi. Abrange recursos, visor, operação, configurações de parâmetros, instalação, códigos de erro e integração com aplicativos para um gerenciamento preciso da temperatura.