Gewiss GWD6916

GEWISS P-COMFORT GWD6916 Wired Load Management Relay User Manual

Model: GWD6916 | Brand: Gewiss

1. Introdução

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the GEWISS P-COMFORT GWD6916 Wired Load Management Relay. Please read this manual thoroughly before attempting any installation or operation.

The GEWISS P-COMFORT GWD6916 is designed to manage electrical loads in an installation, optimizing energy consumption and preventing overloads. It is a wired version, ensuring reliable communication and control.

Informações de segurança

  • Instalação profissional: Installation and maintenance must be performed by qualified personnel in accordance with local electrical codes and regulations.
  • Desconecte a energia: Always disconnect the main power supply before performing any installation, wiring, or maintenance procedures.
  • Volumetage: Garantir o fornecimento voltage matches the device's specifications (250 Volt).
  • Condições ambientais: Não exponha o dispositivo à umidade, temperaturas extremas ou ambientes corrosivos.

2. Conteúdo da embalagem

Ao abrir a embalagem, verifique se todos os itens estão presentes e sem danos:

  • 1 x GEWISS P-COMFORT GWD6916 Wired Load Management Relay
  • 1 x Manual de Instruções (este documento)
GEWISS P-COMFORT GWD6916 Wired Load Management Relay, front view

Imagem 1: Frente view of the GEWISS P-COMFORT GWD6916 Wired Load Management Relay. The image shows the compact housing, terminal blocks for wiring, and indicator lights.

3. Instalação

Follow these steps for proper installation of the GEWISS P-COMFORT GWD6916 relay.

3.1 Montagem

  1. Selecione o local: Choose a suitable location within an electrical enclosure, ensuring adequate ventilation and protection from environmental factors.
  2. Montagem: The relay is designed for DIN rail mounting. Securely attach the device to the DIN rail until it clicks into place.

3.2 fios

Aviso: Ensure power is disconnected before proceeding with wiring.

  1. Fonte de energia: Connect the main power supply (250 Volt) to the designated input terminals as indicated on the device's wiring diagram.
  2. Conexões de carga: Connect the loads to be managed by the relay to the output terminals. Ensure correct polarity and current ratings are observed.
  3. Entrada de controle: Connect the control signal (e.g., from a master load management unit or energy meter) to the dedicated control input terminals. This signal dictates when loads should be shed or reconnected.
  4. Aterramento: Ensure proper grounding of the device and associated electrical components.

Refer to the detailed wiring diagram printed on the device or included in the packaging for specific terminal assignments.

4. Operação

Once installed and wired correctly, the GEWISS P-COMFORT GWD6916 relay operates automatically based on the control input it receives.

4.1 Inicialização e verificação inicial

  1. Restaurar energia: After completing all wiring and safety checks, restore power to the installation.
  2. Luzes indicadoras: Observe the indicator lights on the relay. A power indicator should illuminate, confirming the device is receiving power. Other indicators will show the status of the loads being managed.

4.2 Load Management Function

The relay functions by switching connected loads ON or OFF in response to a control signal. Typically, this signal originates from a central load management system that monitors total energy consumption. When the total consumption exceeds a predefined threshold, the control system signals the relay to disconnect non-essential loads (load shedding) to prevent an overload. When consumption drops, the loads are reconnected.

4.3 Indicadores de Status

The relay features LED indicators to provide visual feedback on its operational status:

  • LED de energia: Indicates that the device is powered ON.
  • LED de status: May indicate operational status, errors, or communication status with the control unit. Refer to the device's specific documentation for LED behavior.
  • Load Status LEDs: Individual LEDs may indicate the ON/OFF status of each controlled load.

5. Manutenção

The GEWISS P-COMFORT GWD6916 relay is designed for reliable, long-term operation with minimal maintenance.

  • Limpeza: Limpe periodicamente a parte externa do dispositivo com um pano macio e seco. Não utilize produtos de limpeza abrasivos ou solventes.
  • Inspeção: Annually, or as required by local regulations, have a qualified electrician inspect the wiring connections for tightness and signs of wear or damage.
  • Nenhuma peça que possa ser reparada pelo usuário: The device contains no user-serviceable parts. Do not attempt to open or repair the unit.

6. Solução De Problemas

If you encounter issues with your GEWISS P-COMFORT GWD6916 relay, refer to the following common problems and solutions:

ProblemaPossível causaSolução
Device has no power (Power LED off)No power supply, loose wiring, tripped circuit breaker.Check main power supply. Verify wiring connections. Reset circuit breaker.
Loads are not switching ON/OFF as expectedIncorrect control signal, faulty wiring to loads, internal fault.Verify the control signal from the master unit. Check wiring to loads. If problem persists, consult a qualified electrician.
Ruídos ou cheiros incomunsInternal component failure, overheating.Immediately disconnect power. Do not attempt to operate. Contact a qualified electrician or Gewiss support.

For issues not listed above or if troubleshooting steps do not resolve the problem, contact a qualified electrician or Gewiss technical support.

7. Especificações

RecursoDetalhe
ModeloGWD6916
MarcaGewiss
TipoWired Load Management Relay
Volumetage250 volts
Dimensões (C x L x A)10 x 8 x 4 cm
Peso60 g
MontagemTrilho DIN

8. Garantia e Suporte

The GEWISS P-COMFORT GWD6916 is covered by a standard manufacturer's warranty. Please refer to the warranty card included with your purchase or visit the official Gewiss website para obter termos e condições detalhados da garantia.

For technical assistance, product inquiries, or warranty claims, please contact Gewiss customer support through their official channels. Ensure you have your product model number (GWD6916) and purchase details available when contacting support.

Gewiss Official Website: www.gewiss.com

Documentos relacionados - GWD6916

Préview GEWISS CHORUSMART CVD 4X10A DIN Rail LED Dimmer Booster - Technical Specifications
Detailed technical specifications and installation guide for the GEWISS CHORUSMART CVD 4X10A DIN rail booster, designed to extend LED dimmer control capacity.
Préview GEWISS JOINON GWJ8037 & GWJ8038 RJ45 Network Interface Installation Guide
Installation and system overview for GEWISS JOINON GWJ8037 (1PH) and GWJ8038 (3PH) RJ45 CAT. 5 F/UTP network interface modules, including wiring diagrams and system integration with solar power.
Préview GEWISS Chorusmart GW10677/GW10678 Auxiliary Axial Command Module: Installation and Technical Guide
Comprehensive guide for GEWISS Chorusmart GW10677 and GW10678 auxiliary axial command modules. Covers safety, general information, LED functions, connection examples, assembly, maintenance, and technical specifications for smart home automation.
Préview Gewiss CHORUSMART Connected Axial Dimmer Module Installation and Technical Guide
Comprehensive guide for the Gewiss CHORUSMART Connected Axial Dimmer Module (GWA1221, GWA1222), covering installation, functions, technical specifications, Zigbee connectivity, and safety information.
Préview GEWISS SMART [3] LED Lighting Fixture - Installation Guide and Warnings
Installation guide and safety warnings for the GEWISS SMART [3] LED lighting fixture. Learn about IP66/IP69 ratings, outdoor installation precautions, and electrical safety.
Préview GEWISS CHORUSMART Booster for CVD LED Dimmer 4x16A - DIN Rail Mounting
Technical specifications and installation guide for the GEWISS CHORUSMART Booster, model GW90768, designed to extend CVD LED dimmer control capacity up to 16A per channel. Suitable for DIN rail mounting and KNX systems.