The SINOTIMER MC701 is a versatile digital PID temperature controller designed for precise heating and cooling applications. It features an LCD display, supports various input types including PT100 and K-type thermocouples, and provides SSR/Relay output with alarm functions. This manual provides essential information for the safe and effective operation of your MC701 controller.

Figura 1.1: Frente view of the MC701 controller showing the PV and SV displays, and control buttons.

Figura 1.2: Angulado view of the MC701 controller, highlighting the model number (MC701-611) and default input type (K).
2. Principais características
- High-precision digital PID temperature control.
- Dual LCD display for Process Value (PV) and Set Value (SV).
- Supports multiple input types: K-type thermocouple, PT100 RTD.
- SSR (Solid State Relay) and Relay output options.
- Configurable heating and cooling control modes.
- Integrated alarm functions (ALM1, ALM2).
- Temperature unit selection: Celsius (°C) or Fahrenheit (°F).
3. Informações de segurança
Leia e compreenda todas as instruções de segurança antes da instalação e operação. O não cumprimento dessas instruções pode resultar em choque elétrico, incêndio ou ferimentos graves.
- Certifique-se de que a fonte de alimentação voltage matches the controller's specifications (100-240V AC).
- Toda a fiação deve ser feita por um eletricista qualificado.
- Disconnect power before making any wiring connections or performing maintenance.
- Não utilize o controlador em ambientes com excesso de umidade, poeira ou gases corrosivos.
- Garanta ventilação adequada para evitar superaquecimento.
- This device is not intended for life-support systems or applications where malfunction could lead to severe injury or property damage.
4. Configuração e instalação
Proper installation is crucial for the accurate and reliable operation of the MC701 controller.
4.1 Montagem
The MC701 is designed for panel mounting. Ensure adequate space for ventilation and wiring connections.

Figure 4.1: MC701 controller shown with its included mounting clips for panel installation.
4.2 Conexões de Fiação
Refer to the wiring diagram on the side of the unit and the instructions below for correct connections. Use appropriate gauge wires for all connections.

Figure 4.2: Detailed wiring diagram on the side of the MC701 unit, showing connections for power, sensor input, SSR, and relay outputs.
- Power Supply (85-265VAC): Connect to terminals 8 and 9.
- SSR Output (OUT): Connect to terminals 10 (+) and 11 (-).
- Relay Output (RELAY): Connect to terminals 13 (NO - Normally Open) and 14 (NC - Normally Closed). Terminal 12 is the common (COM).
- RTD Input (PT100): Connect to terminals 4 (A), 5 (B), and 6 (B).
- Thermocouple Input (TC): Connect to terminals 5 (+) and 6 (-).
- Alarm Outputs (AL1, AL2): Connect to terminals 1, 2, and 3.
5. Instruções de operação
5.1 Exibiçãoview
The MC701 features a dual display:
- PV (Process Value): Displays the current measured temperature.
- SV (Set Value): Displays the desired target temperature.
Luzes indicadoras:
- OUT: Indicates output status (heating/cooling).
- AT: Auto-tuning indicator.
- ALM1, ALM2: Alarm indicators.
5.2 Funções dos botões
- SET: Enters parameter setting mode or confirms a setting.
- < (R/S): Shifts cursor during setting, or resets alarm.
- V (Down Arrow): Decreases value during setting.
- ^ (Up Arrow): Increases value during setting.
5.3 Setting the Target Temperature (SV)
- Pressione o DEFINIR Pressione o botão uma vez. O visor SV começará a piscar.
- Use o ^ e V botões para ajustar a temperatura desejada.
- Use o < button to shift the cursor for faster adjustment.
- Imprensa DEFINIR again to confirm the new SV and exit the setting mode.
5.4 Advanced Parameter Settings
To access advanced parameters (e.g., PID parameters, alarm settings, input type, temperature unit), press and hold the DEFINIR button for several seconds until the first parameter code appears on the PV display.
- Usar ^ e V to navigate through parameters.
- Imprensa DEFINIR para view or edit a parameter's value.
- Ajuste o valor usando ^, V, e <.
- Imprensa DEFINIR to save the value and return to the parameter list.
- To exit advanced settings, press and hold DEFINIR again, or wait for a timeout.
6. Manutenção
Regular maintenance ensures the longevity and optimal performance of your MC701 controller.
- Cleaning: Wipe the display and casinLimpe com um pano macio e seco. Não utilize produtos de limpeza abrasivos ou solventes.
- Ventilation: Ensure the ventilation slots on the sides of the unit are not obstructed to prevent overheating.
- Connections: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Storage: If storing the unit, keep it in a dry, dust-free environment within its specified operating temperature range.
7. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| Display shows "HHHH" or "LLLL" | Sensor open circuit or short circuit; temperature exceeds range. | Check sensor wiring and connection. Verify sensor type matches setting. Ensure temperature is within range. |
| Controller not heating/cooling | Output wiring incorrect; SV not set correctly; PID parameters need tuning. | Check output wiring (SSR/Relay). Confirm SV is set to desired temperature. Perform auto-tuning if necessary. |
| A temperatura varia bastante. | PID parameters not optimized; sensor placement. | Perform auto-tuning. Ensure sensor is placed correctly and securely. |
| Sem problema de exibição/energia | Sem fonte de alimentação; fiação incorreta. | Check power connections (terminals 8 & 9). Verify power source is active. |
8. Especificações

Figura 8.1: Lateral view of the MC701 controller displaying its detailed specification label.
| Parâmetro | Valor |
|---|---|
| Modelo | MC701 |
| Marca | SINOTIMER |
| Tipo de entrada | K-type Thermocouple (default), PT100 RTD |
| Faixa de temperatura | 0-1300°C (K-type), configurable for other types |
| Tipo de saída | Relay / SSR |
| Fonte de energia | 100-240 V CA, 50/60 Hz |
| Tipo de exibição | LED (PV: Red, SV: Green) |
| Classe de precisão | 0.5 |
| Temperatura de operação | 0-50°C (approximate, typical for electronics) |
| País de origem | China |
| UPC | 780744817811 |
9. Garantia e Suporte
For technical support or warranty inquiries, please contact SINOTIMER customer service through the retailer or the official SINOTIMER website. Please have your product model number (MC701) and purchase details ready.