1. Produto acabadoview
O registroTag UHADO-16 is a versatile, multi-use USB PDF temperature and humidity data logger. It features a built-in display that shows the most recent readings and can generate comprehensive reports (PDF, CSV, LTD) without requiring proprietary software or hardware at the destination. Users can also review minimum and maximum recorded trip values directly on the display without needing a PC.

Figura 1: LogTag UHADO-16 Multi-use Data Logger
2. Principais características
- Records and displays Temperature & Humidity readings simultaneously.
- Stores up to 16,000 sets of recordings, sufficient for extended monitoring periods.
- Real-time clock provides accurate date/time stamps for every recording.
- Equipped with a USB micro-port for direct connection to a computer.
- Automatically generates PDF, CSV, and LTD reports without requiring specialized software.
- Supports fast data download using the standard LogTag Interface cradle (sold separately).
- User-configurable settings for alarm thresholds, logging intervals, and trip duration.
- Allows for in-transit inspections to be recorded with a simple button press.
- Features a user-replaceable coin cell battery.

Figure 2: Key features of the UHADO-16 Data Logger
3. O que está na caixa
- 1 x LogTag UHADO-16 Temp/RH logger with display and USB
4. Configuração
Before initial use, it is recommended to configure the UHADO-16 data logger using the LogTag Analyzer software. This software allows you to set parameters such as logging interval, alarm thresholds, and start/stop conditions. The logger connects to your computer via its integrated USB micro-port or an optional LogTag Interface cradle for faster downloads.

Figura 3: LogTag UHADO-16 connected via an Interface Cradle (sold separately)
5. Instruções de operação
The UHADO-16 data logger is designed for straightforward operation. Below are instructions for starting, stopping, and reviewenviando dados diretamente para o dispositivo.
5.1. Iniciando o Registrador
To begin logging, press and hold the INÍCIO / MARCA botão até que o visor mostre GRAV+ or GRAVAÇÃO. If the logger is pre-configured for a delayed start, it will show dts (date/time start) or St (start delay) before logging begins. If configured for a push-button start, PREPARAR will display until the button is pressed.
5.2. Ref.viewing Data During Logging
During active logging, the display will show the current temperature and humidity. You can review the minimum and maximum recorded values by briefly pressing the STOP/REVIEW button. Each press will cycle through the current reading, maximum temperature (MÁXIMO), and minimum temperature (MÍNIMO). A checkmark indicates no alarm excursions, while an arrow or cross symbol indicates an alarm threshold has been triggered or an alarm event occurred.
5.3. Parando o Registrador
If the logger is configured for manual stopping, press and hold the STOP/REVIEW botão até PAROU appears on the display. Logging will cease, and the recording indicator will disappear. After stopping, a checkmark or cross symbol will indicate if any alarm events occurred during the entire logging period.
5.4. Marking an Event
During logging, a brief press of the INÍCIO / MARCA button will place an inspection mark in the data. The MARCA symbol will appear on the display and remain until the next reading is taken. This mark will be visible in the downloaded data, indicating a specific event or inspection point.
5.5. Instructional Video
For a visual guide on operating the UHADO-16, please watch the official instructional video below:
Video 1: Instructions for UHADO-16 Data Logger
This video provides a detailed walkthrough of the UHADO-16's display indicators and button functionalities, including how to start logging, review minimum/maximum temperatures, and stop the device.
6. Manutenção
6.1. Substituição da bateria
The UHADO-16 uses a user-replaceable CR2032 coin cell battery. When the battery indicator on the display shows low power, replace the battery promptly to ensure continuous and accurate logging. Refer to the detailed instructions provided with the device for safe battery replacement procedures.
7. Solução De Problemas
If you encounter any issues with your LogTag UHADO-16, consider the following:
- Dispositivo não responde: Verifique o nível da bateria. Se estiver baixo, substitua a bateria CR2032.
- Problemas de transferência de dados: Ensure the logger is correctly inserted into the USB port or interface cradle. Verify that the LogTag Analyzer software is installed and running.
- Leituras imprecisas: Ensure the logger is placed in an environment where air can circulate freely around it and is not exposed to direct heat sources or extreme conditions beyond its specified operating range.
- Display Blank: This typically indicates a depleted battery. Replace the battery.
For further assistance, refer to the comprehensive troubleshooting guide available on the LogTag website or contact LogTag apoiar.
8. Especificações
| Atributo | Valor |
|---|---|
| Número do modelo do item | UHADO-16 |
| Dimensões da embalagem | 5.55 x 3.98 x 1.54 polegadas |
| Peso do item | 2.08 onças |
| Baterias | 1 bateria CR2032 necessária (incluída) |
| Descrição da bateria | Lítio |
| Cor | Branco/Azul |
| Tipo de montagem | Mesa |
| Classificação de temperatura superior | 158 graus Fahrenheit |
| Fabricante | RegistroTag América do Norte, Inc. |
9. Garantia e Suporte
Specific warranty details for the LogTag UHADO-16 are typically provided at the point of purchase or within the product packaging. For detailed warranty information, please refer to your purchase documentation or visit the official LogTag website.
RegistroTag offers comprehensive support through its global distributor network, reaching over 100 countries worldwide. For technical assistance, product inquiries, or to find a local distributor, please visit the RegistroTag Compre na Amazon or the main LogTag website.