1. Produto acabadoview
The Hantek HDP135V6 is a single-channel programmable DC power supply designed for various electronic applications. It offers precise control over voltage and current output, with a maximum output of 35V and 6A. Key features include a clear 4-digit display, multiple protection mechanisms, and memory settings for frequently used configurations.

Figura 1.1: Frente view of the Hantek HDP135V6 Programmable DC Power Supply, showing the display, control knobs, and output terminals.
Principais características:
- Easy setup with two separate rapid adjustment knobs for voltage e atual.
- Visor de 4 dígitos para volumetage and current, with 10mV/1mA resolution.
- Selectable 230V/115V input voltage.
- Maximum output of 35V/6A.
- Standard 5~12V USB quick charge port.
- 10 save/recall memory settings (M1-M10).
- Comprehensive protection features: Over Current (OC), Over Voltage (OV), Overload, Overheat, and Short-circuit protection.
- Key lock function to prevent accidental changes.
- Output ON/OFF switch lock.
- Smart temperature-controlled cooling fan.
- Design compacto e leve para portabilidade.
2. Instruções de segurança
To ensure safe operation and prevent damage to the device or connected equipment, please read and follow these safety instructions carefully.
- Fonte de energia: Ensure the power supply is connected to a grounded AC outlet with the correct voltage. Verify the AC selector switch on the rear panel is set to the appropriate voltage (115V or 230V) for your region before connecting the power cord.
- Ventilação: Do not block the ventilation openings on the device. Ensure adequate airflow around the unit to prevent overheating.
- Ambiente: Operate the power supply in a dry, well-ventilated area, away from direct sunlight, high temperatures, humidity, and dust.
- Conexão de carga: Always connect the load to the output terminals before turning on the output. Ensure the load is within the specified voltage and current limits of the power supply.
- Terminais de saída: Do not touch the output terminals when the power supply is operating.
- Manutenção: Encaminhe todos os serviços de manutenção a pessoal qualificado. Não tente abrir ou reparar a unidade por conta própria.
- Fusível: Substitua os fusíveis apenas por fusíveis do tipo e especificação corretos.
3. Configuração
3.1 Desembalagem e Inspeção
Upon receiving your Hantek HDP135V6, carefully unpack the unit and inspect it for any signs of damage during transit. Retain the packaging materials for future transport or storage.
3.2 Conexão de Energia
- Locate the AC selector switch on the rear panel of the power supply.
- Set the switch to the appropriate voltage para a sua região (115V ou 230V). Incorrect setting can cause damage to the unit.
- Connect the provided AC power cord to the power input socket on the rear panel and then to a grounded AC outlet.

Figura 3.1: Traseira view of the Hantek HDP135V6, highlighting the AC selector switch, power input, and cooling fan.
3.3 Controles e Indicadores do Painel Frontal
O painel frontal fornece todos os controles e indicadores necessários para operar a fonte de alimentação.
- Volumetage Exibição: Shows the set or actual output voltage.
- Exibição atual: Shows the set or actual output current.
- VolumetagBotão de ajuste: Usado para definir o volume de saídatage.
- Botão de ajuste de corrente: Utilizado para definir o limite da corrente de saída.
- Botões M1-M10: Memory buttons for saving and recalling settings.
- Botão ON/OFF: Toggles the output power.
- Botão Shift: Used in combination with other buttons for advanced functions.
- Botão de bloqueio: Activates/deactivates the key lock function.
- Output Terminals (+, -, GND): Connect your load here.
- Quick Charger USB Port: Provides 5~12V USB output.
4. Instruções de operação
4.1 Operação básica
- Ensure the power supply is properly connected to AC power.
- Press the main power switch on the rear panel to turn on the unit. The display will illuminate.
- Vol de configuraçãotage: Gire o Volumetage Botão de ajuste para definir o volume de saída desejadotage.
- Definir o limite atual: Gire o Botão de ajuste de corrente to set the desired maximum output current. This acts as a current limit for your connected load.
- Conexão de carga: Connect your device or circuit to the output terminals (Red for positive '+', Black for negative '-', Green for Ground 'GND').
- Ativando a saída: Pressione o LIGADO/DESLIGADO button on the front panel to enable the output. The display will show the actual output voltage e atual.
- Deactivating Output: Pressione o LIGADO/DESLIGADO button again to disable the output.
4.2 Funções de memória (M1-M10)
The power supply allows you to save and recall up to 10 sets of voltage e configurações atuais.
- Salvando configurações: Defina o vol desejadotage and current. Press and hold the Mudança button, then press one of the M1-M10 buttons until the display indicates the setting is saved.
- Recuperando configurações: Pressione o desejado M1-M10 button to recall the saved voltage e configurações atuais.
4.3 Funções de proteção
The HDP135V6 includes several protection features to safeguard the unit and connected devices:
- Proteção contra sobrecorrente (OCP): Automatically limits or shuts down output if current exceeds the set limit.
- Mais de Voltage Proteção (OVP): Shuts down output if voltage exceeds a preset limit.
- Proteção contra sobrecarga: Protege contra consumo excessivo de energia.
- Proteção contra superaquecimento: Activates the cooling fan and may shut down if internal temperature is too high.
- Proteção contra curto-circuito: Immediately cuts off output in case of a short circuit.
4.4 Função de bloqueio de teclas
To prevent accidental changes to settings during operation, you can activate the key lock function.
- Ativar bloqueio: Pressione o Trancar button. A lock icon will appear on the display.
- Desativar bloqueio: Pressione o Trancar button again. The lock icon will disappear.
4.5 USB Quick Charge
The front panel features a USB port for quick charging compatible devices. This port provides a variable output from 5V to 12V, depending on the connected device's charging protocol.
5. Manutenção
5.1 Limpeza
To clean the exterior of the power supply, use a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the unit is powered off and disconnected from the AC supply before cleaning.
5.2 Substituição de fusíveis
If the power supply fails to power on, the fuse may need replacement. The fuse holder is located on the rear panel, integrated with the AC input socket.
- Disconnect the power supply from the AC outlet.
- Using a small flat-head screwdriver, gently pry open the fuse compartment within the AC input socket.
- Remove the old fuse and replace it with a new fuse of the same type and rating (e.g., 5.0AT/250V for 110V/115V input, or 3.15AT/250V for 220V/230V input). Refer to the rating label on the rear panel.
- Feche o compartimento dos fusíveis com segurança.
6. Solução De Problemas
If you encounter issues with your Hantek HDP135V6, refer to the following common problems and solutions:
| Problema | Possível causa | Solução |
|---|---|---|
| A unidade não liga. | No AC power, faulty power cord, blown fuse, incorrect AC selector setting. | Check AC power connection. Verify AC selector switch is correct. Replace fuse if blown (refer to Section 5.2). |
| Sem vol. De saídatage / atual. | Output is OFF, OCP/OVP activated, short circuit in load. | Press the ON/OFF button to enable output. Check for OCP/OVP indicators. Disconnect load and check for short circuits. |
| Volume de saídatage/current is unstable or incorrect. | Loose connections, faulty load, internal issue. | Check all connections. Test with a different load. If problem persists, contact support. |
| A unidade superaquece. | Ventilação obstruída, sobrecarga. | Ensure ventilation openings are clear. Reduce load or operate in a cooler environment. |
| Volume inesperadotage spikes on output activation. | Characteristic of power supply design, especially with very light or no load. | Always connect a suitable load before activating output. Monitor output carefully, especially with sensitive devices. If critical, consider adding a dummy load or using a power supply with soft-start features. |
7. Especificações
| Parâmetro | Valor |
|---|---|
| Modelo | HDP135V6 |
| Volume de saídatage | 0-35V |
| Corrente de saída | 0-6A |
| Volumetage Resolução | 10mV |
| Resolução Atual | 1mA |
| Vol de entradatage | 115V/230V AC (Switchable) |
| Potência de saídatage | 210 Watts |
| Saída de carga rápida USB | 5~12V |
| Dimensões do produto (C x L x A) | 5.91 x 3.35 x 9.06 polegadas (150 x 85 x 230 mm) |
| Peso do item | 4.44 libras (2.01 kg) |
| Fabricante | Qingdao Hantek Eletrônico Co., Ltd. |
8. Garantia e Suporte
8.1 Informações de garantia
Hantek products are typically covered by a manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or contact Hantek customer service for specific warranty terms and conditions.
8.2 Suporte ao cliente
For technical assistance, troubleshooting, or service inquiries, please contact Hantek customer support. Contact information can usually be found on the manufacturer's official website ou na embalagem do produto.