1. Introdução

Thank you for choosing the Activa 3 Liters Volcano Quick Water Heater Geyser. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new water heater. Please read this manual thoroughly before installation and use, and keep it for future reference.

This instant water heater is designed to provide hot water quickly and efficiently, featuring a 3-liter capacity, a 3 KVA ISI Copper Element, and a durable 0.8mm Anti Rust Coated 304L Pure Stainless Steel Tank. It includes an Auto Cut-Off function and an ABS Body, ensuring both performance and safety.

Activa Volcano Quick Water Heater Geyser

Figure 1: Activa Volcano Quick Water Heater Geyser

2. Precauções de segurança

Your safety is paramount. Please adhere to the following precautions to prevent accidents and ensure proper functioning of the geyser:

  • Ensure water supply before turning on the geyser.
  • Do not install the geyser yourself. Installation must be performed by a skilled electrician or qualified technician.
  • There should be no inflammable material around the geyser.
  • Turn OFF the power supply when the geyser is not in use or during maintenance.
  • Read the manual carefully before installing the geyser.
  • Install the geyser at the appropriate height on the wall, ensuring it is securely mounted.
  • Always ensure the water heater is completely full with water before switching on the power supply. To ensure this, open the outlet and inlet valve fully until there are no air pockets or bubbles in the water flowing out of the outlet valve.
  • The hexagonal safety valve (pressure relief valve) fitted on the coupling on the inlet pipe will take care of any positive pressure exceeding 3.5 kg/cm² (50 p.s.i.) by opening and starting to drip. Do not block this valve.
  • If a hydro-pneumatic water pump supplies water or the head of feeding overhead tank exceeds 18 meters, a PRESSURE REDUCING VALVE is to be fitted in the inlet pipe to protect the water heater from excessive pressure.
Advanced Safety Features of Activa Water Heater

Figure 2: Advanced Safety Features

3. Configuração e instalação

Installation of the Activa Volcano Quick Water Heater should be carried out by a qualified professional to ensure safety and proper functioning. Follow these general steps:

  1. Seleção do Site: Choose a suitable wall location, ensuring it is sturdy enough to support the geyser's weight when full of water. The location should be near water inlet/outlet points and a power source.
  2. Montagem: Securely mount the geyser to the wall using appropriate fasteners. Ensure it is level and at the recommended height.
  3. Conexões de água: Connect the cold water inlet (usually blue) and hot water outlet (usually red) pipes to the corresponding ports on the geyser. Use appropriate plumbing fittings and ensure all connections are watertight.
  4. Enchimento do tanque: Before connecting to power, open the hot water tap in your sink or shower and then slowly open the cold water inlet valve to the geyser. Allow water to flow through the geyser until a steady stream of water comes out of the hot water tap, indicating the tank is full and all air has been purged. Close the hot water tap.
  5. Conexão elétrica: Connect the geyser to a dedicated and properly grounded electrical outlet. Ensure the voltage e wattage match the product specifications.
Activa Water Heater heating water quickly

Figure 3: Heats water quickly for immediate use

4. Instruções de operação

Once the geyser is properly installed and filled with water, you can begin operation:

  1. Ligar: Ensure the water heater is full of water (as per installation step 3.4). Then, switch on the main power supply to the geyser.
  2. Indicador de aquecimento: The red indicator light will illuminate, signifying that the heating element is active and water is being heated.
  3. Desligamento automático: Once the water temperature attains the preset value (maximum 75 degrees Celsius), the red indicator light will turn off, and the green indicator light will glow, indicating that the geyser has reached the desired temperature and the heating element has automatically cut off.
  4. Uso de água quente: You can now open your hot water tap to access heated water.
  5. Operação contínua: The geyser will automatically reheat water as needed to maintain the set temperature.
Activa Water Heater Rapid Heating

Figure 4: Rapid Heating Capability

5. Manutenção

Regular maintenance ensures the longevity and efficiency of your Activa water heater:

  • Limpeza: Periodically clean the exterior of the geyser with a soft, damp pano. Não use produtos de limpeza abrasivos ou solventes.
  • Descalcificação: The geyser features anti-scaling properties. However, in areas with hard water, mineral deposits can accumulate over time. It is recommended to have the heating element and tank descaled by a qualified technician annually to maintain efficiency.
  • Verificação da válvula de segurança: Occasionally check the pressure relief valve for any blockages or leaks. If it drips excessively, consult a technician.
  • Desligue quando não estiver em uso: For extended periods of non-use, it is advisable to turn off the power supply to the geyser.

6. Solução De Problemas

If you encounter issues with your Activa water heater, refer to the table below for common problems and solutions. For complex issues, contact customer support.

ProblemaPossível causaSolução
No hot water / Geyser not turning onNo power supply; Thermal cut-out activated; Faulty heating element.Check power connection and circuit breaker. If thermal cut-out activates, it indicates a fault; contact service center.
Água não está quente o suficienteInsufficient heating time; Mineral buildup.Ensure geyser is on for sufficient time. If problem persists, consider descaling by a technician.
Water dripping from safety valveNormal operation due to pressure build-up; Excessive water pressure.A small amount of dripping is normal. If excessive, install a pressure reducing valve in the inlet line (refer to Safety Precautions).
Unusual noise from geyserAcúmulo de sedimentos no tanque.Contact a qualified technician for inspection and cleaning.

In the rare case of thermostat failure, the thermal cut-out provides protection against dry heating of the element and excessive heating. The company provides an inbuilt service alarm system which will alert as the thermostat fails. The movement of the alarm alerts you should immediately switch off the power supply connected to the geyser and call our Service Center through your dealer for thermostat calibration.

7. Especificações

Below are the key specifications for the Activa 3 Liters Volcano Quick Water Heater Geyser:

RecursoEspecificação
MarcaATIVAÇÃO
Número do modeloVolcano 3L
Dimensões do produto20 cm de largura x 30 cm de altura
O quetage3000 Watts
Capacidade3 litros
Características especiaisLightweight, Overheat Protection, Rustproof
CorMulticolorido
Temperatura Máxima75 graus Celsius
EficiênciaEficiência Energética
Tipo de montagemParede
Material do tanque0.8mm Anti Rust Coated 304L Pure Stainless Steel
Material do corpoCorpo em ABS
Peso do item3 kg 20 g
País de origemÍndia
Activa Water Heater Dimensions

Figure 5: Product Dimensions (23 cm width, 40 cm height)

8. Garantia e Suporte

The Activa 3 Liters Volcano Quick Water Heater Geyser comes with a 5-year warranty. Please note the following terms regarding warranty and service:

  • Product installation is to be done by the customer himself or by a qualified technician at the customer's expense.
  • For warranty claims or any product-related issues, the customer will need to send the product to the service center for repair.
  • The product will be repaired only at our authorized service centers.

For further assistance, warranty claims, or any product-related issues, please contact the manufacturer:

Fabricante: TECHVISION INTERNATIONAL PVT. LTD. INDIA
E-mail: info@ativaappliances.com
Telefone: 9999427599

Documentos relacionados - Volcano 3L

Préview Activa Glow in the Dark 3.5CH RC Helicopter: User Manual and Flight Guide
Comprehensive user manual for the Activa Glow in the Dark 3.5CH RC Helicopter, covering setup, flight instructions, safety warnings, troubleshooting, and warranty information.
Préview Fones de ouvido sem fio Activa com alto-falantes dinâmicos - Manual do usuário e especificações
Manual do usuário completo para os fones de ouvido sem fio Activa com alto-falantes dinâmicos. Inclui guia de início rápido, instruções de operação, especificações do produto, detalhes de carregamento e informações sobre a garantia.
Préview Manual do usuário do climatizador de ar ultraportátil Activa com umidificador e tela sensível ao toque
Manual do usuário do Activa Ultra-Portable Air Cooler, com umidificador atomizador e tela sensível ao toque. Inclui especificações detalhadas do produto, informações sobre a garantia vitalícia limitada, instruções de configuração, operação, manutenção e segurança.
Préview Manual do Usuário dos Blocos Magnéticos Activa
Manual do usuário do conjunto de peças magnéticas para construção Activa, com 100 peças, incluindo introdução, uso das peças magnéticas, ideias de estrutura e garantia vitalícia limitada.
Préview Luz Noturna LED Activa com Sensor Inteligente (Pacote com 6) - Manual do Usuário e Especificações
Manual do usuário e especificações da Luz Noturna LED Activa com Sensor Inteligente (Pacote com 6). Possui acendimento automático ao anoitecer e desligamento ao amanhecer, luz branca fria de 6500K e eficiência energética. Inclui informações sobre a garantia.
Préview Guia do Usuário do Sistema de Clareamento Dental Klear Action - Activa
Official user guide for the Activa Klear Action Tooth Whitening System. Learn how to use the whitening light, gel, and rinse for effective teeth whitening. Includes instructions, safety warnings, troubleshooting, and tips for maintaining a bright smile.