1. Introdução
This manual provides detailed instructions for the installation, operation, and maintenance of the MYPIN FH4-4CRNB Digital Counter. Please read this manual thoroughly before using the device to ensure correct operation and to prevent damage.
2. Informações de segurança
Observe sempre as seguintes precauções de segurança:
- Certifique-se de que a fonte de alimentação voltage matches the device's specifications (90-260V AC/DC).
- Disconnect power before making any wiring connections or performing maintenance.
- A instalação e a fiação devem ser realizadas por pessoal qualificado.
- Não utilize o dispositivo em ambientes com excesso de umidade, poeira ou gases corrosivos.
- Evite expor o dispositivo a vibrações ou impactos fortes.
- Do not disassemble or modify the device; this will void the warranty.
3. Produto acabadoview
The MYPIN FH4-4CRNB is a versatile digital counter designed for industrial applications. It features a clear display, multiple preset functions, and relay output for control. Its compact 48x48mm size makes it suitable for various panel installations.

Figura 3.1: Frente e lateral view of the MYPIN FH4-4CRNB Digital Counter, showing the display, control buttons, and a simplified wiring diagram on the side label.
4. Especificações
| Recurso | Especificação |
|---|---|
| Modelo | FH4-4CRNB |
| Tipo de entrada | Switch / Encoder |
| Tipo de saída | Relay Output (10kHz) |
| Fonte de energia | 90-260V AC / DC |
| Precisão | ±0.1% P.S |
| Dimensões | 48 mm x 48 mm |
| Preset Capability | 4 predefinições |
5. Instalação e Montagem
The FH4-4CRNB counter is designed for panel mounting. Follow these steps for proper installation:
- Cut a panel cutout of 45mm x 45mm (approx.) in the desired mounting location.
- Insert the counter into the cutout from the front.
- Secure the counter using the provided mounting brackets from the rear of the panel.
- Garanta ventilação adequada ao redor do dispositivo para evitar superaquecimento.

Figura 5.1: Traseira view of the MYPIN FH4-4CRNB Digital Counter, showing ventilation slots for proper heat dissipation.
6. Diagrama de Fiação
Refer to the following diagrams for correct wiring connections. Always ensure power is disconnected before wiring.

Figura 6.1: Detalhado view of the terminal block on the MYPIN FH4-4CRNB Digital Counter.

Figure 6.2: Wiring diagram as shown on the side label of the MYPIN FH4-4CRNB Digital Counter.
Conexões terminais:
- Terminals 1 & 2 (NC, NO): Relay Output 1 (Normally Closed, Normally Open)
- Terminals 3 & 4 (NC, NO): Relay Output 2 (Normally Closed, Normally Open)
- Terminals 5 & 6 (NC, NO): Relay Output 3 (Normally Closed, Normally Open)
- Terminals 7 & 8 (NC, NO): Relay Output 4 (Normally Closed, Normally Open)
- Terminals 9 & 10 (90-260V): AC/DC Power Input (90-260V)
- Terminal 11 (RST): Reiniciar entrada
- Terminal 12 (24V): 24V DC Auxiliary Power Output (for sensors, etc.)
- Terminal INA: Input A (for counting signal)
- Terminal INB: Input B (for counting signal, direction, or phase)
- Terminal GND: Ground for inputs
Observação: The specific function of INA and INB may vary based on the selected counting mode (e.g., single input, quadrature input). Refer to the device's on-screen menu for mode configuration.
7. Operação
After successful wiring and power-up, the counter will display the current count. The front panel typically includes buttons for setting parameters and controlling the count.
Funções básicas:
- Contando: The device counts pulses received on the input terminals (INA/INB).
- Preset Setting: Use the front panel buttons to navigate menus and set up to 4 preset values. When the count reaches a preset value, the corresponding relay output will activate.
- Restabelecer: The count can be reset manually via a front panel button or externally via the RST input terminal.
- Seleção de modo: The counter supports various counting modes (e.g., up/down counting, batch counting, frequency measurement). These modes are typically configured through the device's internal menu system.
Detailed instructions for menu navigation and parameter setting are usually provided in the device's on-screen interface or a separate programming guide.
8. Manutenção
The MYPIN FH4-4CRNB Digital Counter requires minimal maintenance. Follow these guidelines to ensure longevity:
- Limpeza: Limpe suavemente a tela e casinLimpe com um pano macio e seco. Não utilize produtos de limpeza abrasivos ou solventes.
- Inspeção: Verifique periodicamente se as conexões da fiação estão bem apertadas e se apresentam sinais de desgaste ou corrosão.
- Ambiente: Assegurar que o ambiente operacional permaneça dentro das faixas de temperatura e umidade especificadas.
9. Solução De Problemas
If you encounter issues with your digital counter, refer to the following common problems and solutions:
| Problema | Possível causa | Solução |
|---|---|---|
| O dispositivo não liga. | Sem fonte de alimentação ou volume incorretotage. | Verifique as conexões de energia e certifique-se da voltagem.tage is within 90-260V AC/DC. |
| Counter not counting. | Incorrect input wiring, faulty sensor, or incorrect counting mode. | Verify input wiring (INA, INB, GND). Test the sensor. Check counting mode settings in the menu. |
| Relay output not activating. | Preset value not reached, incorrect output wiring, or faulty relay. | Confirm the count has reached the preset. Check relay output wiring. Test the relay if possible. |
| O display mostra o código de erro. | Internal error or parameter setting issue. | Refer to the device's specific error code list (if available) or try resetting the device to factory defaults. |
10. Garantia e Suporte
Information regarding product warranty and technical support was not provided in the available product data. Please refer to the retailer or manufacturer's official website for warranty terms and contact information for technical assistance.