1. Introdução
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Senville AURA Series Mini Split Air Conditioner Heat Pump. Please read this manual thoroughly before operating the unit to ensure proper use and to prevent damage.
The Senville AURA Series is designed to provide efficient cooling and heating for various spaces, including individual rooms, additions, garages, and commercial applications. It features DC Inverter Technology for high efficiency and quiet operation.

Figure 1.1: Complete Senville AURA Series Mini Split System Components.
2. Informações de segurança
Always adhere to the following safety precautions to reduce the risk of fire, electric shock, injury, or property damage.
- Installation must be performed by qualified personnel in accordance with all applicable local and national codes.
- Certifique-se de que a fonte de alimentação corresponde às especificações da unidade (208-230V).
- Não introduza os dedos ou objetos na entrada/saída de ar.
- Não tente consertar o aparelho por conta própria. Contate pessoal de serviço qualificado.
- Desligue a fonte de alimentação antes de limpar ou realizar qualquer manutenção.
3. Componentes do produto
The Senville AURA Series SENA-48HF/F system includes the following main components:
- (5) 9000 BTU Indoor Air Handlers
- (1) 48000 BTU Outdoor Condenser
- Controles remotos sem fio (um para cada unidade interna)
- Pre-charged refrigerant lines (up to 125 ft)
- Installation accessories (drain hoses, electrical wiring, insulation tape)

Figure 3.1: Indoor Air Handler Unit.

Figura 3.2: Controle remoto sem fio.

Figure 3.3: Included Installation Accessories.
4. Instalação e configuração
Installation of the Senville AURA Series mini split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC technician.
4.1 Lista de verificação de pré-instalação
- Verifique se todos os componentes estão presentes e sem danos.
- Garanta espaço suficiente para as unidades internas e externas, permitindo a circulação adequada de ar e o acesso para manutenção.
- Confirm electrical supply meets 208-230V requirements and dedicated circuit is available.
4.2 Etapas de Instalação (Mais deview (para Técnico)
- Mount indoor air handlers in desired locations, ensuring proper drainage.
- Position the outdoor condenser unit on a stable, level surface, away from obstructions.
- Connect refrigerant lines between indoor and outdoor units. The system is pre-charged for up to 125 feet of line.
- Conecte a fiação elétrica de acordo com o diagrama de fiação fornecido no manual de instalação completo.
- Realize a aspiração de vácuo das linhas de refrigerante para remover o ar e a umidade.
- Check for leaks using appropriate methods.
- Open service valves to release refrigerant.
- Teste o sistema para verificar se está funcionando corretamente nos modos de resfriamento e aquecimento.
5. Instruções de operação
Your Senville AURA Series system is designed for user-friendly operation via the wireless remote control.
5.1 Funções de controle remoto
Refer to Figure 3.2 for a visual guide to the remote control buttons.
- Botão de energia: Liga / desliga a unidade.
- Botão de modo: Alterna entre os modos de operação: Automático, Resfriamento, Desumidificação, Aquecimento e Ventilação.
- Ajuste de temperatura: Use as setas PARA CIMA/PARA BAIXO para definir a temperatura desejada.
- Velocidade do ventilador: Ajusta a velocidade da ventoinha (Automático, Baixa, Média, Alta).
- Balanço: Controla o movimento de abertura das venezianas para distribuição do ar.
- Equipamento ecológico: Ativa o modo de economia de energia.
- Temporizador: Define temporizadores de LIGAR/DESLIGAR para funcionamento programado.
Modos de Operação 5.2
- Modo legal: Provides cooling. Ideal for summer months.
- Modo de aquecimento: Provides heating. Effective down to -22°F (-30°C) with Arctic Heat Pump technology.
- Modo Seco: Desumidifica o ar.
- Modo fã: Circula o ar sem aquecer ou resfriar.
- Modo automático: Seleciona automaticamente o modo de resfriamento ou aquecimento com base na temperatura ambiente.

Figure 5.1: Operating Temperature Range.
5.3 Recursos inteligentes
- Whisper Technology: Ensures quiet operation, with noise levels as low as 23.5 dB.
- Smart Saving: Built-in intelligent eye detects human movement to automatically adjust operation and save energy.
- Controles inteligentes: Compatible with voice control (e.g., Alexa) and app control (requires Alexa Kit installation).

Figure 5.2: Low Noise Operation.

Figure 5.3: Smart Saving Feature.

Figure 5.4: Smart Controls with Alexa Integration.
6. Manutenção
Regular maintenance ensures optimal performance and longevity of your Senville AURA system.
6.1 Limpeza do Filtro
- Limpe os filtros de ar a cada duas semanas ou com mais frequência, dependendo do uso e da qualidade do ar.
- Open the front panel of the indoor unit, remove filters, and wash with lukewarm water.
- Deixe os filtros secarem completamente antes de reinseri-los.
6.2 Manutenção da Unidade Externa
- Mantenha a área ao redor da unidade externa livre de detritos, folhas e neve.
- Limpe periodicamente a serpentina externa com uma escova macia ou aspirador de pó.
- Ensure proper drainage from the outdoor unit.
6.3 Manutenção Profissional
It is recommended to have a certified HVAC technician perform annual inspections and maintenance, including checking refrigerant levels, electrical connections, and overall system performance.
7. Solução De Problemas
Antes de entrar em contato com o suporte ao cliente, consulte os problemas e soluções mais comuns a seguir:
| Problema | Possível causa | Solução |
|---|---|---|
| A unidade não liga. | Sem energia, pilhas do controle remoto descarregadas, disjuntor desarmado. | Verifique a fonte de alimentação, substitua as pilhas do controle remoto e reinicie o disjuntor. |
| Refrigeração/aquecimento insuficiente. | Filtros de ar sujos, unidade externa bloqueada, configuração de modo incorreta, baixo nível de refrigerante. | Limpe os filtros, remova obstruções, selecione o modo correto e contate um técnico para verificação do fluido refrigerante. |
| Ruído incomum. | Peças soltas, obstrução do ventilador, ruídos normais de funcionamento (ex.: fluxo de refrigerante). | Inspect for loose parts, remove obstructions. If persistent or loud, contact technician. |
| Vazamento de água da unidade interna. | Mangueira de drenagem entupida, instalação incorreta. | Verifique e limpe a mangueira de drenagem. Se o problema persistir, entre em contato com um técnico. |
8. Especificações técnicas
| Recurso | Especificação |
|---|---|
| Número do modelo | SENA-48HF/F |
| Capacidade | 48000 BTU (4 toneladas) |
| Unidades internas | (5) 9000 BTU Air Handlers |
| Unidade externa | (1) 48000 BTU Condenser |
| Volumetage | 208-230 Volts |
| Eficiência (SEER) | 22.0 |
| Nível de ruído (em ambiente interno) | 23.5 dB (Whisper Technology) |
| Dimensões do produto | 48"D x 48"W x 60"H (Overall System) |
| Características especiais | Heating and Cooling Function, DC Inverter Technology, Smart Saving, Smart Controls (Alexa compatible) |
| Certificações | ETL Intertek Approved, AHRI Certified, ENERGYSTAR |
9. Informações de garantia
The Senville AURA Series is backed by a comprehensive warranty:
- Garantia das peças: 5 anos
- Garantia do compressor: 10 anos
For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Senville website.
10. Suporte ao cliente
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Senville customer support.
- Website: Visit the Senville Store on Amazon
- Consultas gerais: Refer to the contact information provided in your product packaging or on the official Senville website.

Figure 10.1: Senville Customer Support.