RG RayGalax RG-524-2P

RG RayGalax 2x4 LED Flat Panel Light User Manual

Model: RG-524-2P

1. Introdução

Thank you for choosing the RG RayGalax 2x4 LED Flat Panel Light. This product is designed to provide efficient, adjustable, and high-quality illumination for various indoor environments. With selectable color temperatures (CCT) and power modes, along with 0-10V dimming capability, this LED panel light offers versatile lighting solutions while significantly reducing energy consumption.

This manual provides detailed instructions for the safe installation, operation, and maintenance of your new LED panel light. Please read it thoroughly before installation and retain it for future reference.

2. Informações de segurança

AVISO: Risco de choque elétrico. Desligue a energia no fusível ou disjuntor antes de instalar ou realizar qualquer manutenção.

  • Leia todas as instruções cuidadosamente antes da instalação.
  • A instalação deve ser realizada por um eletricista qualificado, de acordo com as normas elétricas nacionais e locais.
  • Garantir o fornecimento voltage is compatible with the fixture's requirements (120-277V AC).
  • Do not install in wet locations. This product has an IP40 moisture-proof rating, suitable for indoor use only.
  • Não manuseie o aparelho com as mãos molhadas.
  • Evite olhar diretamente para a fonte de luz LED quando estiver acesa.
  • Certifique-se de que a luminária esteja fixada com segurança para evitar quedas.
  • Não modifique o acessório de forma alguma. Modificações não autorizadas podem anular a garantia e criar riscos à segurança.

3. Conteúdo da embalagem

The RG RayGalax 2x4 LED Flat Panel Light package typically includes:

  • 2 x RG RayGalax 2x4 LED Flat Panel Light Fixtures
  • 1 x Manual do Usuário
  • Mounting clips for recessed installation

Note: Hanging and flush mounting kits are not included and must be purchased separately if required for your installation type.

4. Recursos do Produto

Adjustable Color Temperature (CCT)

Select from 5 color temperatures to suit your environment and preference:

  • 3500 mil (Branco Quente)
  • 4000 mil (Neutral White)
  • 5000 mil (Branco brilhante)
  • 5700 mil (Daylight White)
  • 6500 mil (Cool White)

The CCT selection switch is located on the side of the driver. Adjust before installation.

Close-up of CCT and Power Select Switches on the LED panel light driver.

Image: Detail of the switches for adjusting color temperature and wattage on the light fixture's driver.

Adjustable Power Modes (Wattage)

Choose from 5 wattage settings to control brightness and energy consumption:

  • 25 W (3250 LM)
  • 30 W (3900 LM)
  • 35 W (4550 LM)
  • 40 W (5080 LM)
  • 50 W (6250 LM)

O wattage selection switch is also located on the side of the driver. Adjust before installation.

Visual comparison of 5 different wattage settings and their corresponding brightness levels in an office environment.

Image: Illustration demonstrating the visual difference in brightness for each of the 5 selectable wattage modes (25W to 50W).

0-10V Dimerizável

Enjoy smooth, continuous dimming from 5% to 100% when connected to a compatible 0-10V dimmer (dimmer not included). This feature allows for precise control over lighting levels without flicker or noise.

Series of images showing the LED panel light dimming from 100% to 5% brightness.

Image: Visual representation of the 0-10V dimming capability, showing the light fixture at various brightness levels from 100% down to 5%.

Energy Saving & Long Lifespan

Designed with high-efficiency LED chips, this panel light can save up to 72% on electricity bills compared to traditional 140W fluorescent lamps. With a lifespan of over 50,000 hours, it eliminates frequent bulb replacements and maintains light quality without yellowing or darkening.

Comparison image showing energy savings of LED panel light versus traditional fluorescent lighting.

Image: A side-by-side comparison illustrating the energy efficiency of the RG RayGalax LED panel light (72% energy saving) against a traditional 140W fluorescent fixture.

Certifications & Quality

This product is ETL, FCC, RoHS, and CE certified, ensuring high standards of safety and performance. It also features an IP40 moisture-proof rating, making it suitable for various indoor environments.

Instalação versátil

Supports three installation methods: Recessed, Surface Mounted, and Drop Mounted. Recessed installation hardware is included. Surface and Drop mounting kits are sold separately.

Diagram showing three installation methods: Surface Mounted, Recessed Mounted, and Drop Mounted.

Image: Illustrations depicting the three possible installation types for the LED panel light: Surface Mounted (frame not included), Recessed Mounted (direct use with clips), and Drop Mounted (cables not included).

5. Especificações

AtributoValor
MarcaRG RayGalax
Número do modeloRG-524-2P
Dimensões do produto50.19"C x 27.16"L x 3.93"A
Peso do item18.51 libras
MaterialAlumínio, Acrílico
CorBranco
Tipo de fonte de luzLIDERADO
Volumetage120-277 Volts AC
O quetage (ajustável)25 W, 30 W, 35 W, 40 W, 50 W
Brilho (Máx.)6250 lúmens (a 50 W)
Color Temperature (Adjustable)3500K, 4000K, 5000K, 5700K, 6500K
Escurecimento0-10V Dimmable (dimmer not included)
Vida útil50,000 horas
CertificaçõesETL, FCC, RoHS, CE
Classificação IPIP40 (Moisture-proof)
Tipo de instalaçãoRecessed (clips included), Surface/Drop (kits not included)
Uso interno/externoSomente para uso interno

6. Setup & Installation Guide

This section details the recessed installation process. For surface or drop mounting, please refer to the instructions provided with the respective mounting kits (sold separately).

Etapas de pré-instalação:

  1. Segurança em primeiro lugar: Turn off the power at the circuit breaker before beginning any installation work.
  2. Descompacte: Carefully remove the LED panel light from its packaging. Inspect for any damage.
  3. Ajustar configurações: Before installation, use the switches on the side of the driver to select your desired Color Temperature (CCT) and Wattage. These settings are difficult to change once the panel is installed.
Image showing the CCT and Power Select Switches on the side of the LED panel light driver.

Image: Close-up of the Color Select Switch and Power Select Switch on the LED panel light. Ensure these are set before installation.

Etapas de instalação embutida:

This method is for installation into a T-grid ceiling system.

  1. Etapa 1: Prepare o teto

    Turn off the power at the breaker. Remove the existing ceiling tile from the desired installation location.

    Step 1 of recessed installation: Turning off power and removing ceiling tile.

    Image: Illustration of turning off power and removing a ceiling tile to prepare for recessed light installation.

  2. Etapa 2: conexões de fios

    Open the driver box cover. Connect the AC power wires (Live, Neutral, Ground) from the building's electrical supply to the corresponding wires on the LED panel's driver. If using a 0-10V dimmer, connect the dimming wires (purple and gray) to the dimmer circuit. Ensure all connections are secure and insulated.

    Step 2 of recessed installation: Opening driver box and connecting wires.

    Image: Illustration showing the process of opening the driver box and connecting electrical wires to the LED panel light.

  3. Step 3: Secure the Panel

    Place the LED panel light into the T-grid ceiling opening. Bend each T-grid clip 90° away from the fixture housing, then bend the top part 90° again. Secure these clips onto the T-grid railing to hold the fixture in place.

    Step 3 of recessed installation: Placing the panel into the grid and securing with clips.

    Image: Illustration demonstrating how to place the LED panel into the ceiling grid and secure it using the integrated mounting clips.

  4. Etapa 4: Ligar

    Once the fixture is securely installed and all wiring is complete, restore power at the circuit breaker. Test the light and dimming function.

    Step 4 of recessed installation: Turning on the power to test the installed light.

    Image: Illustration showing the final step of turning on the power after successful installation of the LED panel light.

7. Instruções de operação

Adjusting Color Temperature (CCT) and Wattage:

The CCT and wattage settings are adjusted via switches located on the side of the LED driver. These adjustments should ideally be made before installation for convenience, but can be accessed if the panel is removed or if the driver is accessible.

  1. Seleção CCT: Locate the "Color Select Switch" on the driver. Slide the switch to choose between 3500K, 4000K, 5000K, 5700K, or 6500K.
  2. O quetage Seleção: Locate the "Power Select Switch" on the driver. Slide the switch to select your desired wattage: 25W, 30W, 35W, 40W, or 50W.

Note: Changes to CCT and wattage will take effect immediately upon selection.

0-10V Escurecimento:

If your fixture is connected to a compatible 0-10V dimmer switch (not included), you can control the brightness level from 5% to 100%. Operate the dimmer switch according to its manufacturer's instructions.

Ensure the dimmer is compatible with 0-10V LED drivers for optimal performance and to avoid damage.

8. Manutenção

The RG RayGalax LED Flat Panel Light requires minimal maintenance due to its long lifespan and durable construction.

  • Limpeza: Certifique-se de que a energia esteja desligada antes de limpar. Use um pano macio, seco ou levemente umedecido.amp cloth to wipe the surface of the panel. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the finish or acrylic diffuser.
  • Inspeção: Inspecione periodicamente a luminária para verificar se há sinais de danos ou conexões soltas. Se encontrar algum problema, desligue a energia e consulte um eletricista qualificado.
  • Nenhuma peça que possa ser reparada pelo usuário: There are no user-serviceable parts inside the fixture. Do not attempt to open or repair the unit yourself.

9. Solução De Problemas

Se você encontrar problemas com seu painel de LED, consulte os problemas e soluções comuns a seguir:

ProblemaPossível causaSolução
A luz não acende.
  • Sem fonte de alimentação.
  • Conexão de fiação solta.
  • Interruptor ou disjuntor com defeito.
  • Incorrect CCT/Wattage configuração do interruptor.
  • Verifique se o disjuntor está LIGADO.
  • Verifique se todas as conexões dos fios estão seguras.
  • Test the switch or breaker.
  • Ensure CCT/Wattage switches are set to a valid position.
A luz pisca ou escurece inesperadamente.
  • Interruptor dimmer incompatível.
  • Fiação solta.
  • Volumetage flutuações.
  • Certifique-se de usar um dimmer compatível com 0-10V.
  • Verifique todas as conexões elétricas.
  • Consulte um eletricista para verificar a estabilidade do fornecimento de energia.
A intensidade da luz está muito baixa/alta.
  • O que está incorretotage configuração.
  • Dimmer set too low/high.
  • Ajuste o wattage ligue o driver.
  • Adjust the 0-10V dimmer to the desired level.
A temperatura da cor não está como esperado.
  • Configuração incorreta do CCT.
  • Adjust the CCT switch on the driver to the desired color.

If the problem persists after attempting these solutions, please contact RG RayGalax customer support for assistance.

10. Garantia e suporte

RG RayGalax stands behind the quality of its products. This LED drop ceiling light comes with ETL, FCC, RoHS, and CE certifications, ensuring its reliability and safety.

For any quality issues or concerns, please do not hesitate to contact us. Your satisfaction is our primary concern. Please refer to your purchase documentation or the RG RayGalax official webConsulte o site para obter os termos específicos da garantia e informações de contato.

Informações de contato:

  • Website: Visit the RG RayGalax Store on Amazon
  • E-mail: (Consulte a embalagem do produto ou o manual oficial) weblocal)
  • Telefone: (Consulte a embalagem do produto ou o manual oficial) weblocal)

Documentos relacionados - RG-524-2P

Préview Luminária de embutir LED ASD - Iluminação comercial de alta qualidade
Descubra a luminária de embutir LED ASD, uma solução de iluminação versátil e eficiente em termos energéticos para espaços comerciais e industriais. Com temperatura de cor e potência selecionáveis, bateria de reserva integrada e um design durável, esta luminária de embutir oferece desempenho superior e longa vida útil. Saiba mais sobre suas especificações técnicas, guia de instalação e apresentação do produto.
Préview Notas de versão dos switches Ruijie série RG-ES ESW_1.0(1)B1P20
Este documento fornece notas de versão para os switches da série Ruijie RG-ES, especificamente para a versão de firmware ESW_1.0(1)B1P20. Ele detalha informações sobre a versão, novos recursos, problemas resolvidos e em aberto, plataformas suportadas, procedimentos de atualização de software e documentação relacionada.
Préview Ruijie Reyee RG-ES200 Series Switches: WebGuia de configuração baseado em
A comprehensive guide to configuring Ruijie Reyee RG-ES200 Series Switches using the web-based interface. Covers login, port settings, VLANs, security, PoE, system settings, monitoring, and FAQs.
Préview SKYSHALO F-Clamp Manual do usuário e especificações
Detailed user manual and specifications for SKYSHALO F-Clamps, including model information, assembly instructions, safety precautions, troubleshooting, and maintenance for various models like FCA and F1500 series.
Préview VEVOR F-CLAMP Manual de Instruções e Especificações Técnicas
Guia completo para VEVOR F-CLAMPS, incluindo detalhes do modelo, instruções de montagem, precauções de segurança, solução de problemas, manutenção e informações de garantia.
Préview Manual de instalação da unidade fan-coil cassete Trane | Série CWS
Este manual de instalação da Trane Technologies fornece orientações abrangentes para a instalação segura e adequada das unidades fan-coil cassete Trane (série CWS). Ele aborda regras essenciais de segurança, especificações técnicas, conexões mecânicas, hidráulicas e elétricas, limites de operação, manutenção e solução de problemas para diversos modelos.