1. Introdução
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Durastar DRAW06F1B Mini Split Wall Mount Indoor Unit. This unit is designed to provide both cooling and heating capabilities for your space. Please read this manual thoroughly before installation and operation, and keep it for future reference.
Nota importante: This is an indoor evaporator unit only. An outdoor condenser unit is required for proper functionality. Mini split systems must be installed by a qualified HVAC professional in accordance with all local codes and regulations. Failure to do so will void the manufacturer's warranty.
2. Informações de segurança
Your safety and the safety of others are very important. Please read and follow all safety messages outlined in this manual.
- Instalação profissional necessária: Installation, maintenance, and repair of this unit must be performed by a certified HVAC technician. Improper installation can lead to electric shock, fire, water leakage, or other serious injuries.
- Fonte de energia: Ensure the power supply matches the unit's specifications (208 / 230 Volt). Always disconnect power before performing any maintenance or service.
- Aterramento: O aparelho deve ser devidamente aterrado para evitar choque elétrico.
- Autorizações: Maintain adequate clearances around the indoor unit for proper airflow and maintenance access.
- Crianças e animais de estimação: Mantenha crianças e animais de estimação afastados da unidade durante o funcionamento e a manutenção.
- Materiais Inflamáveis: Não coloque materiais inflamáveis ou aerossóis em spray perto da unidade.
3. Product Features and Technologies
The Durastar DRAW06F1B unit incorporates several features designed for enhanced comfort and efficiency:
- Swing/Gentle Airflow: Allows for optimized air circulation and direction throughout the room, ensuring even temperature distribution.
- Modo dormir: Reduces energy consumption by gradually adjusting the temperature and automatically turning off after 8 hours, returning to normal operation.
- Controle remoto sem fio com tecnologia "Siga-me": The remote control features a built-in temperature sensor. When activated, the unit will optimize the temperature based on the remote's location, providing maximum comfort where you are.
- Reinicialização automática: In the event of a power failure, the unit will automatically restart with the previously set operating parameters once power is restored.
- Função de temporizador de 24 horas: Allows you to program the unit to automatically turn on or off at a specified time within a 24-hour period.
- Revestimento anticorrosivo para aletas (revestimento dourado para aletas): Both indoor and outdoor units feature this specialized coating to protect against corrosion, enhancing the longevity and reliability of the system.
- Operação silenciosa: Engineered for low noise levels, ensuring a peaceful indoor environment.
4. Configuração e instalação
As previously stated, the installation of this mini split indoor unit requires professional expertise. This section provides a general overview for informational purposes.
4.1. Verificação de pré-instalação
- Verifique se todos os componentes estão presentes e sem danos.
- Ensure the installation location meets clearance requirements and can support the unit's weight.
- Confirm compatibility with your outdoor condenser unit.
4.2. Etapas de Instalação (Mais deview for Professional)
- Mounting Plate Installation: Securely attach the mounting plate to the wall, ensuring it is level.
- Wall Hole Drilling: Drill a hole through the wall for refrigerant piping, drain hose, and electrical wiring.
- Piping and Wiring Connection: Connect the refrigerant lines, drain hose, and electrical cables between the indoor and outdoor units. This step requires specialized tools and knowledge.
- Indoor Unit Mounting: Carefully mount the indoor unit onto the mounting plate.
- Vacuuming and Refrigerant Charging: Evacuate the refrigerant lines and charge the system with the correct amount of refrigerant.
- Test Run: Perform a test run to ensure proper operation and check for leaks.

Image: The Durastar mini split indoor unit seamlessly integrated into a modern living room, demonstrating its wall-mounted design. Adjacent to this, an outdoor condenser unit is shown installed on the side of a house, illustrating the complete system setup.
5. Instruções de operação
Your Durastar mini split unit is operated primarily via the wireless remote control.

Image: The Durastar indoor unit, a sleek white rectangular device designed for wall mounting, is shown alongside its compact wireless remote control. The remote features a digital display and various buttons for mode selection, temperature adjustment, and fan speed.
5.1. Funções de controle remoto
- Botão de energia: Liga ou desliga a unidade.
- Botão de modo: Alterna entre os modos de operação: Automático, Resfriamento, Desumidificação, Aquecimento e Ventilação.
- Botões de ajuste de temperatura (setas para cima/para baixo): Aumenta ou diminui a temperatura definida.
- Botão de velocidade do ventilador: Ajusta a velocidade do ventilador (Automático, Baixa, Média, Alta).
- Botão de balanço: Activates or deactivates the automatic louver swing for even air distribution.
- Botão de suspensão: Activates Sleep Mode for energy-efficient nighttime operation.
- Botão do temporizador: Define o temporizador de 24 horas para ligar/desligar.
- "Follow Me" Button: Activates the "Follow Me" function, allowing the unit to sense temperature at the remote's location.
5.2. Operação básica
- Point the remote control directly at the indoor unit.
- Pressione o botão Liga / Desliga para ligar a unidade.
- Press the Mode button to select your desired operating mode (e.g., Cool for cooling, Heat for heating).
- Use the Temperature Adjustment buttons to set your desired room temperature.
- Adjust the Fan Speed or activate the Swing function as needed for comfort.
6. Manutenção
Regular maintenance ensures optimal performance and longevity of your mini split system. Always disconnect power to the unit before performing any maintenance.
6.1. Limpeza do filtro de ar
- The air filters should be cleaned every two weeks, or more frequently depending on usage and air quality.
- Abra o painel frontal da unidade interna.
- Remova os filtros de ar.
- Limpe os filtros com um aspirador de pó ou lave-os com água morna e detergente neutro.
- Deixe os filtros secarem completamente antes de reinstalá-los.
6.2. Limpeza da serpentina
- The indoor coil should be inspected and cleaned annually by a professional technician.
- The outdoor coil should also be cleaned regularly to remove dirt, leaves, and debris.
6.3. Inspeção Geral
- Check for any unusual noises or odors.
- Ensure the drain hose is clear and not obstructed.
- Inspecione as conexões elétricas para verificar se há sinais de desgaste ou danos.
7. Solução De Problemas
Before contacting customer support, please refer to the following common issues and solutions. For complex problems, always consult a qualified technician.
| Problema | Possível causa | Solução |
|---|---|---|
| A unidade não liga. | Sem energia; Pilhas do controle remoto descarregadas; Disjuntor desarmado. | Verifique a ligação elétrica; Substitua as pilhas do controle remoto; Reinicie o disjuntor. |
| Refrigeração/aquecimento insuficiente. | Filtros de ar sujos; Unidade externa obstruída; Configuração de modo incorreta; Nível baixo de refrigerante. | Limpe os filtros de ar; remova quaisquer obstruções da unidade externa; selecione o modo correto; contate um técnico para verificação do fluido refrigerante. |
| Ruído incomum vindo da unidade. | Loose parts; Obstruction in fan; Normal expansion/contraction sounds. | Check for loose parts (professional); Remove obstructions; Normal sounds are usually minor clicks or gurgles. |
| Vazamento de água da unidade interna. | Clogged drain hose; Improper installation angle. | Clear drain hose; Contact technician for re-installation or inspection. |
8. Especificações
Key technical specifications for the Durastar DRAW06F1B Mini Split Indoor Unit:
| Especificação | Valor |
|---|---|
| Marca | Durastar |
| Número do modelo | DRAW06F1B |
| Capacidade de resfriamento | 6,000 BTU |
| Capacidade de aquecimento | 7,000 BTU |
| Volumetage | 208 / 230 Volts |
| Tipo de instalação | Montagem na parede |
| Nível de ruído | 56 dB (Máx.) |
| Dimensões (D x L x A) | 7.88"P x 11.5"L x 11.5"A |
| Cor | Branco |
| Características especiais | Remote Controlled, Auto Restart, 24-Hour Timer, Anti-Corrosive Fin Coating |

Imagem: Um profissional lateralfile view of the Durastar indoor unit, highlighting its slim design and wall-mounting capabilities.
9. Garantia e Suporte
Durastar products are engineered for durability and performance.
9.1. Informações de garantia
Please note that any manufacturer warranty for this mini split unit will be voided if the installation is not performed by a professional in accordance with local codes. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact Durastar customer service.
9.2. Suporte ao cliente
For questions, assistance with multi-zone systems, or technical support, please contact Durastar experts at:
Telefone: (855) 484-3292
Our support team is available to assist you with any inquiries regarding your Durastar mini split system.