Introdução
O Amplimite Ampmed Non Contact/No Touch Digital Forehead Thermometer provides a safe, hygienic, and accurate way to measure temperature for all ages. Its advanced infrared technology ensures quick and reliable readings, making it an essential tool for home health monitoring.
Informações importantes de segurança
Read all instructions before use. This device is intended for household use only. Do not immerse the thermometer in water or other liquids. Keep out of reach of children. Do not drop or expose to direct sunlight or extreme temperatures. Consult a healthcare professional for any health concerns.
O que está na caixa
Seu Amplimite Ampmed Thermometer package includes:
- Amplimite Ampmed Non Contact/No Touch Digital Forehead Thermometer
- 2 pilhas AAA
- Estojo de armazenamento
- Manual do usuário

Esta imagem exibe o Amplimite Ampmed Non Contact Thermometer alongside its custom-fit storage case and the two AAA batteries that power it, highlighting the complete package contents.
Características do produto
- Medição sem contato: Provides hygienic, touchless temperature readings from the forehead.
- Rápido e preciso: Delivers quick and precise results.
- Large Color LCD Display: Easy-to-read screen with color-coded indicators (green for normal, yellow for elevated, red for high temperature).
- Alarme de febre: Audible alert for temperatures exceeding 100.4°F (38°C).
- Função de memória: Stores up to 32 previous readings for tracking temperature trends.
- Funcionalidade multimodo: Capable of measuring body temperature, object/liquid temperature, and room temperature.
- Celsius/Fahrenheit Switchable: Alterne facilmente entre unidades de temperatura.
- Desligamento automático: Automatically powers off after 30 seconds of inactivity to conserve battery life.
- Operado por bateria: Uses 2 AAA batteries (included).

A visual representation of the thermometer's main functionalities, including its large LCD display, high accuracy, memory for 32 readings, ultra-fast measurement, and color-coded fever indicator. It also highlights modes for forehead, surface, and room temperature, along with features like a buzzer, unit conversion, fever alarm, auto-off, and battery operation.
Guia de configuração
Instalação da bateria
O Amplimite Ampmed Thermometer requires 2 AAA batteries. These are included in your package.
- Localize o compartimento da bateria na parte traseira do termômetro.
- Abra a tampa da bateria.
- Insert the 2 AAA batteries, ensuring correct polarity (+ and - ends match the markings inside the compartment).
- Feche a tampa da bateria com segurança.
This video provides a visual guide to installing the batteries and a general overview do Amplim No Touch Forehead Thermometer's features and operation.
Instruções de operação
Taking Body Temperature (Forehead Mode)
- Certifique-se de que o termômetro esteja no Modo Corporal (ícone de pessoa exibido).
- Hold the thermometer about 1 to 2 inches (2.5 to 5 cm) away from the center of the forehead. Ensure no hair or sweat obstructs the area.
- Pressione o "Scan/Opt" botão.
- The temperature reading will appear on the LCD screen within one second, accompanied by an audible beep.
- Observe the screen color: Green for normal, Yellow for elevated, Red for high temperature.

This image demonstrates the versatility of the Amplimite Ampmed thermometer, showing it in use for temperature measurement on individuals across various age groups, from infants to adults and the elderly.

A detailed diagram of the thermometer, clearly labeling its components such as the sensor, LCD screen, and various control buttons for power, memory, and scanning, aiding in user familiarity.

This image explains the thermometer's color-coded display system, which visually indicates temperature ranges: green for normal, orange for elevated, and red for high temperatures, providing an immediate visual alert.
Taking Object/Liquid Temperature (Object Mode)
- Ensure the thermometer is in Object Mode (object icon displayed).
- Point the thermometer at the object or liquid you wish to measure.
- Pressione o "Scan/Opt" botão.
- The temperature reading will appear on the LCD screen.
Taking Room Temperature (Room Mode)
- Ensure the thermometer is in Room Mode (house icon displayed).
- Point the thermometer towards an open area in the room.
- Pressione o "Scan/Opt" botão.
- A temperatura ambiente da sala será exibida.

This image highlights the thermometer's three measurement modes: body temperature, liquid temperature (demonstrated with a glass of milk), and ambient room temperature, showcasing its broad utility.
Alternando entre Celsius e Fahrenheit
Para alternar entre Celsius (°C) e Fahrenheit (°F), pressione o "MEM/ENTR PWR/SET" Pressione repetidamente o botão até que a unidade desejada seja exibida.

A visual guide to changing the temperature unit on the thermometer, displaying both Fahrenheit and Celsius options and indicating the free storage case.
ViewLeituras de memória
The thermometer stores up to 32 previous temperature readings. To access these, press the "MEM/ENTR PWR/SET" button when the device is on. Each press will cycle through the stored readings.
Cuidados e Manutenção
Limpando o termômetro
Wipe the thermometer body with a soft, dry cloth. For disinfection, use a cloth lightly dampened with 70% isopropyl alcohol. Do not immerse the device in water or use abrasive cleaners.
Armazenar
Store the thermometer in its provided storage case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.
Solução de problemas
| Problema | Possível causa | Solução |
|---|---|---|
| Sem imagem/O dispositivo não liga | As pilhas estão descarregadas ou inseridas incorretamente. | Verifique a polaridade das pilhas ou substitua-as por pilhas AAA novas. |
| Leituras imprecisas | Incorrect measurement distance, forehead obstruction (hair/sweat), or device not acclimated to room temperature. | Ensure correct distance (1-2 inches), clear forehead, and allow thermometer to acclimate to room temperature for 15-30 minutes before use. |
| "Baixo" ou "Alto" exibido | A temperatura está fora da faixa mensurável. | Ensure proper measurement technique and environment. If measuring body temperature, consult a healthcare professional if symptoms persist. |
| Fever alarm not sounding | Alarm function is turned off or temperature is below the fever threshold. | Check device settings to ensure alarm is enabled. Confirm temperature is above 100.4°F (38°C). |
Especificações do produto
- Número do modelo:
- 810477023170 (AMP1708)
- Measurement Range (Body):
- 90.0°F - 109.0°F (32.0°C - 42.9°C)
- Measurement Range (Object/Room):
- 32.0°F - 212.0°F (0.0°C - 100.0°C)
- Precisão:
- ± 0.4 ° F (± 0.2 ° C)
- Resolução da tela:
- 0.1°F / 0.1°C
- Fonte de energia:
- 2 pilhas AAA
- Desligamento automático:
- Aproximadamente. 30 segundos
- Armazenamento de memória:
- 32 leituras
- Dimensões:
- 7.83 x 3.43 x 2.6 polegadas
- Peso:
- 8.78 onças (com pilhas)
- Cor:
- Rosa
- Características especiais:
- Large Display, Non-Contact, Fast Reading System, Auto Off, High Accuracy
- Fabricante:
- Amplimite
- País de origem:
- China
Garantia e Suporte
Amplim products are designed for quality and reliability. For warranty information or technical support, please refer to the contact details provided in your product packaging or visit the official Amplimite website.
This product meets CE and FDA standards and is FSA/HSA approved.