1. Introdução

Thank you for choosing the OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light. This manual provides essential information for the safe installation, operation, and maintenance of your new flood light. Please read these instructions thoroughly before installation and retain them for future reference.

2. Informações de segurança

AVISO: Risco de choque elétrico. Desligue a energia no fusível ou disjuntor antes da instalação ou manutenção.

3. Conteúdo da embalagem

Verifique se todos os componentes estão presentes antes de iniciar a instalação:

4. Produto acabadoview

The OREiN Flood Light features three adjustable LED heads and a motion sensor for comprehensive outdoor illumination and security.

OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light

Figura 1: Frente view of the OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light, showing the three adjustable light heads and the motion sensor below.

Flexible Adjustment Angle of OREiN Flood Light

Figure 2: Diagram illustrating the flexible adjustment angles of the three light heads (340°) and the motion sensor (270° horizontally, 120° vertically).

5. Instalação

This flood light is designed for hardwired installation on a standard junction box (2.75” / 3.5”). It supports both wall and eave mounting.

Etapas de instalação:

  1. Desligue a energia: Disconnect power at the circuit breaker before starting.
  2. Suporte de montagem seguro: Attach the metal mounting bracket to your existing junction box using the provided screws.
  3. Fios de conexão: Connect the household wiring to the fixture wires using the provided wire nuts. Typically, black to black (live), white to white (neutral). This light belongs to secondary luminaires, so no extra ground wire connection is needed.
  4. Fixe a luminária: Align the light fixture with the mounting bracket and secure it with the appropriate screws.
  5. Insert Waterproof Plug: Ensure the waterproof plug is properly inserted to prevent moisture ingress.
  6. Ajuste os faróis e o sensor: Position the three light heads and the motion sensor to cover the desired areas.
  7. Restaurar energia: Ligue novamente a energia no disjuntor.
Installation Diagram for OREiN Flood Light

Figure 3: Step-by-step diagram for hardwired installation, showing mounting bracket, wire connections, and securing the fixture.

Wall Mounted and Soffit Mounted OREiN Flood Light

Figura 4: Examples of wall-mounted and soffit-mounted installations for the flood light.

6. Modos de operação

The OREiN Flood Light offers three operational modes, selectable via a switch on the motion sensor unit:

OREiN Flood Light 3 Modes for Daily Lighting

Figure 5: Visual representation of Test, Dusk to Dawn, and Auto modes in operation.

OREiN Flood Light Dusk to Dawn Mode

Figure 6: Illustration of the Dusk to Dawn mode, showing the light automatically activating when surroundings are dark and deactivating when bright.

7. Ajustando configurações

The motion sensor unit includes dials for adjusting the light's duration and sensitivity:

Adjustable Motion Sensor Dials for OREiN Flood Light

Figure 7: Close-up of the motion sensor with dials for adjusting mode, timer minutes, and sensitivity.

Video 1: Official OREiN video demonstrating the motion sensor outdoor lights, including features like wide detection, adjustable sensing distance, heat dissipation, adjustable time/sensitivity, flexible adjustment, and easy installation.

8. Manutenção

OREiN Flood Light IP65 Waterproof

Figure 8: Illustration demonstrating the IP65 waterproof rating, showing the light functioning reliably under rain.

OREiN Flood Light Good Heat Dissipation

Figure 9: Diagram showing the heat dissipation design of the light heads, contributing to the product's longevity.

9. Solução De Problemas

ProblemaPossível causaSolução
A luz não acende.No power; incorrect wiring; sensor settings.Check circuit breaker. Verify wiring connections. Adjust sensor mode/sensitivity.
A luz permanece acesa continuamente.Sensor in D2D mode; continuous motion detected; sensitivity too high.Switch to Auto mode. Check for constant heat sources or movement in detection zone. Reduce sensitivity.
A luz acende durante o dia.Sensor in Test mode; ambient light sensor blocked.Switch to Auto or D2D mode. Ensure the ambient light sensor is not obstructed.
Motion detection range is too short/long.Sensitivity setting incorrect.Adjust the sensitivity dial on the motion sensor.

10. Especificações

RecursoDetalhe
Nome do modeloOL3600354
MarcaOREiN
Brilho4500 Lúmens
O quetage30 Watts
Temperatura de cor5000 Kelvin (luz do dia)
Volumetage120 Volts
MaterialAcrilonitrila Butadieno Estireno (ABS)
Nível de resistência à águaIP65 à prova d'água
Ângulo de detecção de movimento240°
Distância de detecção de movimentoAté 40 pés
Ajuste da cabeça leveCobertura 340°
Estimativa de vida útil50,000 horas
Tipo de instalaçãoHardwired (Wall Mount, Eave Mount)
Dimensões do produto7.6"C x 8"L x 6"A
Peso do item1.87 libras

11. Garantia e Suporte

OREiN offers an extended warranty for this product. For specific warranty details, please refer to the product packaging or contact OREiN customer support.

Suporte ao cliente:

OREiN Customer Service Representative

Figure 10: Image representing OREiN customer support, available for assistance.