Generac RXSW200A3 & 7101

Generac 200 Amp Automatic Smart Transfer Switch Kit & Battery Heater Pad User Manual

Model: RXSW200A3 & 7101

1. Introdução e Produto Acimaview

This manual provides essential information for the safe and efficient operation of your Generac 200 Amp Single Phase Automatic Smart Transfer Switch Kit and the Generac 7101 Battery Heater Pad. This combined system is designed to ensure continuous power supply during utility outages and maintain optimal battery performance for your standby generator.

O Generac Automatic Transfer Switch is engineered for use with single-phase generators equipped with an Evolution or Nexus Controller. It monitors utility power and automatically transfers the electrical load between utility and generator power, ensuring seamless operation. Its Digital Power Management (DPM) technology allows for the management of up to four individual HVAC (24 VAC controlled) loads without additional hardware.

O Generac 7101 Battery Heater Pad is designed to maintain the optimal temperature of your generator's battery, especially in colder climates. It activates automatically to prevent performance degradation due to low temperatures.

Generac 200 Amp Automatic Smart Transfer Switch Kit and Battery Heater Pad

Figura 1: Overview of the Generac 200 Amp Automatic Smart Transfer Switch Kit and 7101 Battery Heater Pad, showing the transfer switch enclosure, battery heater pad, and associated wiring/ties.

2. Informações de segurança

AVISO: Installation and service must be performed by a qualified electrician or service technician. Improper installation or maintenance can result in serious injury, death, or property damage.

  • Always disconnect all power sources before servicing the transfer switch or battery heater pad.
  • Ensure all local electrical codes and regulations are followed during installation.
  • Utilize equipamento de proteção individual (EPI) adequado, incluindo óculos de segurança e luvas isolantes.
  • Do not operate the transfer switch or heater pad if any components are damaged.
  • Keep children and unauthorized personnel away from the equipment.

3. Componentes do produto

The Generac 200 Amp Automatic Smart Transfer Switch Kit and 7101 Battery Heater Pad include the following main components:

  • Generac 200 Amp Automatic Smart Transfer Switch: Housed in an aluminum NEMA/UL type 3R enclosure.
  • Generac 7101 Battery Heater Pad: Designed for 9kW-22kW air-cooled standby generators.
  • Associated wiring and installation accessories (e.g., cable ties).
Exterior of Generac 200 Amp Automatic Smart Transfer Switch

Figura 2: Exterior view of the Generac 200 Amp Automatic Smart Transfer Switch enclosure.

Interior of Generac 200 Amp Automatic Smart Transfer Switch

Figura 3: Interior view of the Generac 200 Amp Automatic Smart Transfer Switch, showing internal components and wiring terminals.

Generac 7101 Battery Heater Pad with wiring

Figure 4: The Generac 7101 Battery Heater Pad, including its power cable and connection points.

4. Configuração e instalação

Proper installation is crucial for the safe and effective operation of your transfer switch and battery heater pad. It is highly recommended that installation be performed by a certified electrician or Generac authorized service dealer.

4.1. Automatic Transfer Switch Installation

  1. Seleção do Site: Choose a location for the transfer switch that is accessible, protected from severe weather, and in close proximity to both the utility meter and the generator. The NEMA 3R enclosure is suitable for outdoor use.
  2. Montagem: Securely mount the transfer switch enclosure to a sturdy surface using appropriate hardware. Ensure it is level and plumb.
  3. Conexões de fiação:
    • Energia elétrica da concessionária: Connect the utility power lines to the designated terminals within the transfer switch. This unit includes a service disconnect.
    • Generator Power: Connect the generator power lines to the appropriate terminals.
    • Conexões de carga: Connect the household electrical load to the transfer switch output terminals.
    • Fiação de controle: Conecte o baixo volumetage control wires between the transfer switch and the generator's Evolution or Nexus Controller. Refer to your generator's manual for specific control wiring diagrams.
  4. Aterramento e ligação: Ensure proper grounding and neutral bonding as per local electrical codes.
  5. Verificações finais: Before restoring power, double-check all connections for tightness and correct polarity.
interior angulado view of Generac 200 Amp Automatic Smart Transfer Switch

Figura 5: Interior angulado view of the transfer switch, highlighting the utility source connections (N1, N2), generator source, and customer load connections.

4.2. Battery Heater Pad Installation

The Generac 7101 Battery Heater Pad is designed for easy installation under the generator battery. It is compatible with air-cooled standby generators manufactured in 2008 or later. Note: This heater pad is not required for use with AGM-style batteries.

  1. Remoção da bateria: Carefully disconnect and remove the generator battery from its tray.
  2. Posicionamento da almofada: Place the Generac 7101 Battery Heater Pad directly onto the battery tray, ensuring it is centered and flat.
  3. Battery Reinstallation: Carefully place the battery back onto the heater pad in the tray. Reconnect the battery terminals, ensuring correct polarity.
  4. Conexão de fiação: Connect the heater pad's wiring to the designated low-voltage power source on your generator, as specified in your generator's installation manual.
  5. Fiação segura: Use the provided cable ties to secure the heater pad wiring, preventing it from interfering with moving parts or being damaged.
Close-up of Generac 7101 Battery Heater Pad connector

Figura 6: Close view of the connector for the Generac 7101 Battery Heater Pad.

Close-up of Generac 7101 Battery Heater Pad wiring

Figura 7: Detalhado view of the wiring for the Generac 7101 Battery Heater Pad.

5. Instruções de operação

5.1. Automatic Transfer Switch Operation

The Generac Automatic Transfer Switch operates autonomously to manage your home's power supply.

  1. Utility Power Monitoring: The transfer switch continuously monitors the incoming utility power for interruptions or significant voltage flutuações.
  2. Automatic Transfer to Generator: Upon detecting a utility power outage, the transfer switch signals the standby generator to start. Once the generator reaches proper operating voltage and frequency, the transfer switch automatically disconnects the home from utility power and connects it to the generator power. This process is seamless and typically occurs within seconds.
  3. Digital Power Management (DPM): The integrated DPM allows the transfer switch to manage up to four 24 VAC controlled HVAC loads. During generator operation, if the total load approaches the generator's capacity, the DPM will shed non-essential HVAC loads to prevent overload, then reconnect them as capacity becomes available.
  4. Return to Utility Power: When stable utility power is restored, the transfer switch monitors it for a pre-set period to ensure stability. Once confirmed, it automatically transfers the electrical load back to utility power and signals the generator to cool down and shut off.

5.2. Battery Heater Pad Operation

The Generac 7101 Battery Heater Pad operates automatically based on ambient temperature to ensure your generator's battery remains at an optimal temperature for starting.

  • Ativação automática: The heater pad is equipped with a thermostat that activates the heating element when the ambient temperature drops to approximately 40°F (4.4°C).
  • Desativação Automática: The heater pad will turn off when the battery temperature reaches approximately 55°F (12.8°C), preventing overheating and conserving energy.
  • Monitoramento contínuo: The heater pad continuously monitors the temperature, cycling on and off as needed to maintain the battery within the optimal temperature range.

6. Manutenção

Regular maintenance ensures the longevity and reliable operation of your Generac transfer switch and battery heater pad. It is recommended to have these components inspected annually by a qualified technician as part of your generator's maintenance schedule.

  • Inspeção visual: Periodically inspect the transfer switch enclosure for any signs of damage, corrosion, or loose connections. Ensure the enclosure is sealed and free from debris.
  • Verificação da fiação: Verify that all wiring connections are secure and free from fraying or damage.
  • Limpeza: Keep the exterior of the transfer switch and the area around the battery heater pad clean and free of obstructions.
  • Saúde da bateria: Regularly check your generator's battery health. While the heater pad helps with temperature, the battery itself still requires proper charging and occasional testing.
  • Serviço profissional: For internal components of the transfer switch or any electrical issues, contact a Generac authorized service dealer. Do not attempt to service internal electrical components yourself.

7. Solução De Problemas

This section provides basic troubleshooting steps for common issues. For complex problems, always contact a qualified Generac service technician.

ProblemaPossível causaSolução
Transfer switch does not transfer to generator during outage.
  • Generator not starting.
  • Control wiring issue.
  • Transfer switch malfunction.
  • Check generator fuel, oil, and battery.
  • Verify control wiring connections between switch and generator.
  • Contate um técnico qualificado para diagnóstico.
Transfer switch does not return to utility power.
  • Utility power not stable.
  • Transfer switch malfunction.
  • Wait for utility power to stabilize.
  • Contacte um técnico qualificado.
Battery heater pad not warming battery.
  • Temperature above activation threshold.
  • Conexão de fiação solta.
  • Heater pad malfunction.
  • Check ambient temperature (should be below 40°F/4.4°C).
  • Inspect wiring connections to the heater pad.
  • Contacte um técnico qualificado.

Importante: Do not attempt electrical repairs if you are not qualified. Always prioritize safety.

8. Especificações

RecursoEspecificação
Modo de operaçãoAutomático
Classificação atual200 Amps
Vol operacionaltage240 Volts
Tipo de contatoNormalmente aberto
Tipo de conector2 pinos
terminalParafuso
Tipo de Circuito1 vias
Tipo de atuadorAlavanca de dobradiça
Material de contatoAço
Avaliação de proteção internacionalIP67
Número de Posições1
Especificação AtendidaUL
Lower Temperature Rating (Heater Pad Activation)40 graus Fahrenheit (4.4°C)
Upper Temperature Rating (Heater Pad Deactivation)55 graus Fahrenheit (12.8°C)
Método de controleTouch (for DPM interface, if applicable)
Protocolo de conectividadeX-10 (for DPM, if applicable)
CorOrange (Heater Pad)
O quetage6000 Watts (General product specification)
Contagem de unidades1.0 contagem
Número de itens1
FabricanteGerar
MaterialSteel (Transfer Switch Enclosure)

Observação: As especificações estão sujeitas a alterações sem aviso prévio. Consulte o rótulo do produto para obter as informações mais precisas.

9. Garantia e Suporte

Garantia: The Generac 200 Amp Automatic Smart Transfer Switch comes with a Garantia limitada de 5 ano. The Generac 7101 Battery Heater Pad is also covered by Generac's standard accessory warranty. Please retain your proof of purchase for warranty claims.

Apoiar: For technical assistance, troubleshooting beyond this manual, warranty service, or to locate an authorized Generac service dealer, please visit the official Generac website or contact Generac customer support.

Visit the Official Generac Store on Amazon

Documentos relacionados - RXSW200A3 & 7101

Préview Geradores Generac: Soluções Portáteis, Residenciais e Comerciais
Explore a ampla gama de geradores da Generac, incluindo sistemas portáteis, residenciais e comerciais. Conheça os recursos, especificações e aplicações para soluções de energia confiáveis.
Préview Generac HTS "Wn" Type Automatic Transfer Switch Owner's Manual
Owner's Manual for the Generac HTS "Wn" Type Automatic Transfer Switch, detailing installation, operation, and maintenance for models 600-2600 Amp, 600 Volts.
Préview Manual do Proprietário da Chave de Transferência Automática Generac Tipo HS
Manual completo do proprietário para chaves de transferência automática (ATS) Generac tipo HS, modelos 005036-0 (100A) e 004945-1 (200A). Abrange instalação, operação, diretrizes de segurança, dados elétricos, diagramas e informações sobre a garantia.
Préview Diretrizes de instalação dos geradores Generac refrigerados a ar de 60 Hz (16 kW e 22 kW)
Guia de instalação detalhado para geradores de reserva refrigerados a ar Generac de 60 Hz (modelos de 16 kW e 22 kW). Abrange as etapas essenciais, desde a desembalagem e seleção do local até as conexões elétricas e a inicialização, garantindo uma configuração segura e adequada para uma energia de reserva confiável.
Préview Manual do Proprietário dos Geradores Generac Refrigerados a Ar de 60 Hz (10-24 kW)
Manual do proprietário completo para geradores de reserva refrigerados a ar Generac de 60 Hz, abrangendo operação, manutenção, segurança e solução de problemas para modelos que variam de 10 kW a 24 kW.
Préview Geradores residenciais de reserva da série Guardian da Generac (20-24 kW) - Características e especificações
Explore the Generac Guardian Series residential standby generators (20, 22, and 24 kW). This document details key features, advanced technology like True Power™ and Mobile Link™, comprehensive specifications, and compatible accessories for reliable home backup power.