Pulsar PGiPAIRB4

Pulsar PGiPAIRB4 Inverter Generator Parallel Kit

Manual de instruções

Introdução

This manual provides essential instructions for the safe and efficient use of your Pulsar PGiPAIRB4 Inverter Generator Parallel Kit. This kit allows you to connect two compatible Pulsar inverter generators to double their power output, providing increased electrical capacity for various applications, including RV use.

Compatible Pulsar Generator Models: PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO.

Informações de segurança

Always read and understand all safety warnings and instructions in this manual and the manuals of your connected generators before operation. Failure to follow these instructions can result in serious injury or property damage.

  • Ensure all connections are secure before starting generators.
  • Operate generators in a well-ventilated area to prevent carbon monoxide poisoning.
  • Não opere em condições úmidas.
  • Keep children and pets away from operating equipment.
  • Always turn off generators and disconnect spark plug wires before performing any maintenance or making connections.

Conteúdo da embalagem

Verifique se todos os itens estão presentes no seu pacote:

  • Pulsar PGiPAIRB4 Parallel Kit Unit
  • Connection Cables (integrated)
  • Manual do usuário (este documento)
Pulsar PGiPAIRB4 Parallel Kit unit with cables

Image: The Pulsar PGiPAIRB4 Parallel Kit unit, showing the main box with receptacles and circuit breakers, and the integrated connection cables extending from it.

Configuração e conexão

Follow these steps to connect your parallel kit to two compatible Pulsar inverter generators:

  1. Preparação: Ensure both generators are turned off, cooled down, and disconnected from any loads. Place the generators on a level, stable surface in a well-ventilated area.
  2. Connect Parallel Cables: Locate the parallel connection ports on each generator. These are typically color-coded (red and black) and may have specific shapes.
    Close-up of parallel connection cables

    Imagem: Um close-up view of the parallel kit's connection cables, showing the red and black connectors designed to plug into the generators.

    Connect the red cable from the parallel kit to the red parallel port on the first generator. Connect the black cable from the parallel kit to the black parallel port on the first generator. Repeat this process for the second generator.
    Close-up of parallel connection adapters

    Image: Various parallel connection adapters and plugs, illustrating the types of connections used for linking generators.

  3. Conexões seguras: Ensure all connections are firmly seated and secure. Loose connections can cause arcing or power interruptions.
  4. Colocação final: Position the parallel kit unit in a safe, accessible location, away from exhaust fumes and moisture.
    Two Pulsar generators connected with the parallel kit

    Image: Two Pulsar inverter generators shown from the rear, with the PGiPAIRB4 Parallel Kit connected to their respective parallel ports, demonstrating a complete setup.

Instruções de operação

Once the parallel kit is securely connected to both generators:

  1. Start Generators: Start both inverter generators according to their individual operating instructions. Allow them to run for a few moments to stabilize.
  2. Conectar cargas: Plug your electrical loads into the receptacles on the PGiPAIRB4 Parallel Kit.
    • The L14-50 receptacle provides 120/240V output at 50 amps.
    • The L14-30 receptacle provides 120/240V output at 30 amps.
  3. Monitor: Observe the generator and parallel kit for proper operation. The circuit breakers on the parallel kit will trip if an overload occurs.
  4. Desligar: To shut down, first disconnect all loads from the parallel kit. Then, turn off both generators according to their individual instructions. Finally, disconnect the parallel kit cables.

Manutenção

The Pulsar PGiPAIRB4 Parallel Kit requires minimal maintenance. Follow these guidelines:

  • Keep the unit clean and free of dirt, dust, and moisture.
  • Inspect cables and connectors regularly for any signs of wear, damage, or corrosion. Replace if necessary.
  • Store the kit in a dry, protected area when not in use.

Solução de problemas

ProblemaPossível causaSolução
No power output from parallel kit.
  • Generators not started.
  • Conexões soltas.
  • O disjuntor desarmou.
  • Incompatible generators.
  • Ensure both generators are running.
  • Check all parallel cable connections.
  • Reset the circuit breaker on the parallel kit.
  • Verify generators are listed as compatible models.
O disjuntor desarma com frequência.
  • Condição de sobrecarga.
  • Faulty appliance.
  • Reduce the total electrical load.
  • Test appliances individually to identify faulty ones.

Especificações

  • Modelo: PGiPAIRB4
  • Volume de saídatage: 120/240 V
  • Frequência de saída: 60Hz
  • L14-50 Receptacle: 50 Amps
  • L14-30 Receptacle: 30 Amps
  • Geradores compatíveis: Pulsar PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO
  • Dimensões do produto: 12 x 9 x 4 polegadas
  • Peso do item: 3 libras
  • Fabricante: Pulsar

Informações de garantia

For detailed warranty information regarding your Pulsar PGiPAIRB4 Parallel Kit, please refer to the warranty card included with your purchase or visit the official Pulsar Products website. Guarde o comprovante de compra para solicitações de garantia.

Suporte ao cliente

If you have any questions, require technical assistance, or need to order replacement parts, please contact Pulsar Customer Support:

  • Website: www.pulsarproducts.com
  • Refer to your product registration or warranty documentation for specific contact numbers or email addresses.

Documentos relacionados - PGiPAIRB4

Préview Manual do Operador do Gerador Inversor de Combustível Duplo Pulsar 9500 Watts
Este manual do operador fornece instruções completas para o gerador inversor de combustível duplo Pulsar PGD95BiSCO de 9500 watts, abrangendo precauções de segurança, operação, manutenção e solução de problemas.
Préview Manual do Operador do Gerador Inversor a Gasolina Pulsar PG2200BiS
Manual do operador abrangente para o gerador inversor portátil a gasolina Pulsar PG2200BiS, abrangendo segurança, operação, manutenção e solução de problemas para garantir um desempenho confiável.
Préview Manual do Operador do Gerador Inversor Portátil Pulsar PG2000iS/PG2300iS
Este manual do operador fornece informações essenciais para a operação, montagem, manutenção e resolução de problemas dos geradores a gasolina portáteis com inversor Pulsar PG2000iS e PG2300iS, todos seguros. Aprenda a usar seu gerador de forma eficaz e segura.
Préview Manual do Operador do Gerador Inversor Pulsar 1600 Watts PGD16iSCO
Manual do operador completo para o gerador inversor Pulsar PGD16iSCO de 1600 watts. Inclui instruções de segurança detalhadas, procedimentos operacionais, cronogramas de manutenção, guias de solução de problemas e especificações técnicas para uso seguro e eficiente.
Préview Manual do Operador do Gerador a Gasolina Inversor Pulsar PG2300iSCO
Manual do operador completo para o gerador a gasolina inversor Pulsar PG2300iSCO. Este guia abrange informações essenciais, incluindo regras de segurança, características do produto, instruções de montagem, procedimentos operacionais detalhados, cronograma de manutenção, dicas de solução de problemas e um diagrama de fiação para o uso seguro e eficaz do gerador.
Préview Manual do Operador do Gerador Inversor Pulsar PG4500BiSRCO
Manual do operador do gerador inversor Pulsar PG4500BiSRCO, abrangendo segurança, recursos, operação, manutenção e solução de problemas para uso de gasolina e GLP como combustível duplo.