ACCUCOLD ARG6PV-AFZ1PVSTACK

ACCUCOLD Medical Performance Series

All-Refrigerator/All-Freezer Combination

Model: ARG6PV-AFZ1PVSTACK

1. Terminadoview

The ACCUCOLD ARG6PV-AFZ1PVSTACK is a 24-inch Medical Performance Series all-refrigerator and all-freezer combination unit. This stackable system is engineered to meet stringent vaccine storage guidelines, including those from the CDC/VFC. It combines a 6 cubic foot auto-defrost all-refrigerator (ARG6PV) with a 1.4 cubic foot all-freezer (AFZ1PV) into a single, space-efficient footprint using Accucold's StackRack system.

Both units feature microprocessor temperature controllers for precise temperature management and stability, crucial for sensitive medical storage. The refrigerator operates within a range of +2°C to +8°C, while the freezer maintains temperatures between -30°C and -10°C.

Angulado view of the ACCUCOLD stacked medical refrigerator and freezer combination unit.
Figura 1: Angulado view of the ACCUCOLD ARG6PV-AFZ1PVSTACK medical refrigerator-freezer combination, showcasingraças ao seu design compacto e empilhável.

2. Informações de segurança

Instruções importantes de segurança: Read all instructions before using this appliance to reduce the risk of fire, electric shock, or injury.

  • Certifique-se de que o aparelho esteja devidamente aterrado. Conecte-o somente a tomadas devidamente aterradas.
  • Não tente reparar ou substituir qualquer peça do seu aparelho, a menos que seja especificamente recomendado neste manual. Qualquer outra manutenção deve ser encaminhada a um técnico qualificado.
  • Mantenha as aberturas de ventilação no gabinete do aparelho ou na estrutura embutida livres de obstruções.
  • Não utilize dispositivos mecânicos ou outros meios para acelerar o processo de descongelamento, além daqueles recomendados pelo fabricante.
  • Não danifique o circuito refrigerante.
  • Não armazene substâncias explosivas, como latas de aerossol com propulsores inflamáveis, neste aparelho.
  • This appliance is intended for medical and laboratory use. Do not use for general household food storage.

3. Configuração

The ARG6PV-AFZ1PVSTACK unit ships in three separate boxes and requires minor assembly upon delivery. Follow these steps for proper setup:

3.1 Desembalagem

  • Carefully remove all packaging materials from both the refrigerator and freezer units.
  • Inspect both units for any shipping damage. Report any damage immediately to your supplier.
  • Guarde os materiais da embalagem para transporte futuro, se necessário.

3.2 Posicionamento e Ventilação

  • Place the combined unit on a strong, level surface capable of supporting its weight (approximately 150 lbs).
  • Ensure adequate air circulation around the unit. Maintain at least 2 inches (5 cm) of space at the back and sides, and 4 inches (10 cm) at the top for proper ventilation.
  • Avoid placing the unit in direct sunlight or near heat sources such as stoves, heaters, or radiators.

3.3 Stacking Assembly

The StackRack system is used to combine the refrigerator and freezer units. Refer to the separate StackRack assembly instructions for detailed steps. Generally, the freezer unit (AFZ1PV) is placed on top of the refrigerator unit (ARG6PV).

ACCUCOLD stacked medical refrigerator and freezer combination unit with doors open, showing empty interior.
Figure 2: The ACCUCOLD ARG6PV-AFZ1PVSTACK unit with doors open, illustrating the interior layout before loading. The freezer is on top, and the refrigerator is below.

3.4 Instalação da prateleira

Install the wire shelves in both the refrigerator and freezer compartments according to your storage needs. Ensure shelves are securely seated in their supports.

Fechar-se view of an adjustable wire shelf inside the refrigerator unit.
Figure 3: Detail of the adjustable wire shelving system within the refrigerator compartment, designed for flexible storage.

3.5 Conexão elétrica

Plug the units into dedicated, properly grounded electrical outlets. Avoid using extension cords or adapter plugs. Ensure the voltage corresponde aos requisitos da unidade (115 Volts).

3.6 Initial Power-Up and Temperature Stabilization

After plugging in, allow the units to operate empty for at least 4-6 hours to reach stable operating temperatures before loading any contents. Monitor the digital temperature displays to confirm temperatures are within the specified ranges.

4. Instruções de operação

This section details the operation of your ACCUCOLD medical refrigerator-freezer combination.

4.1 Controle de temperatura

  • Both the refrigerator and freezer units are equipped with microprocessor temperature controllers.
  • The refrigerator maintains temperatures between +2°C and +8°C (36°F to 46°F).
  • The freezer maintains temperatures between -30°C and -10°C (-22°F to 14°F).
  • Adjust temperature settings using the digital controls located on the top panel of each unit. Refer to the specific controller manual for detailed programming instructions.

4.2 Alarms and Monitoring

The units feature comprehensive alarm systems to ensure product integrity:

  • Audible and Visual Temperature Alarms: Activate if temperatures go out of the set range.
  • Power Failure Alerts: Notifies users of power interruptions.
  • Door Open Alarms: Sounds if a door is left ajar for an extended period.
  • Sensor Failure Alarms: Indicates a malfunction with the temperature sensor.
  • Contatos de alarme remoto: Both units include remote alarm contacts for integration with external monitoring systems.
Close-up of the remote alarm contacts on the ACCUCOLD unit.
Figure 4: Remote alarm contacts, allowing integration with facility monitoring systems for enhanced safety and compliance.

4.3 Internal Airflow and Probe Port

  • The refrigerator (ARG6PV) utilizes optimized forced air cooling with an internal fan to ensure excellent temperature stability and uniformity, and rapid recovery after door openings.
  • Both units are equipped with a 1/2-inch probe port, allowing for the easy installation of additional temperature monitoring devices without compromising the internal environment.
Close-up of a temperature probe inserted into the probe port inside the unit.
Figure 5: A temperature probe inserted into the dedicated 1/2-inch probe port, facilitating external temperature monitoring.

4.4 Diretrizes de armazenamento

When loading the units, ensure proper spacing between items to allow for adequate air circulation. Do not block the internal fan or air vents.

Interior view of the refrigerator compartment with vaccine boxes stored on shelves.
Figure 6: Interior of the refrigerator compartment showing organized storage of vaccine boxes, demonstrating proper spacing for airflow.

5. Manutenção

Regular maintenance ensures optimal performance and longevity of your ACCUCOLD unit.

5.1 Limpeza

  • Interior: Clean the interior regularly with a mild detergent and warm water. Rinse thoroughly and dry completely to prevent odors and mildew. Remove shelves and drawers for easier cleaning.
  • Exterior: Wipe down the exterior surfaces with a soft cloth and mild cleaner. Avoid abrasive cleaners or solvents.
  • Juntas de porta: Clean door gaskets regularly to ensure a tight seal. A damaged or dirty gasket can lead to temperature fluctuations and increased energy consumption.

5.2 Descongelamento

  • Refrigerator (ARG6PV): This unit features an adjustable cycle defrost system, which automatically manages frost buildup. No manual defrosting is typically required for the refrigerator compartment.
  • Freezer (AFZ1PV): The freezer unit requires manual defrosting. When frost buildup exceeds 1/4 inch (6 mm), turn off the unit, remove all contents, and allow the frost to melt naturally. Do not use sharp objects to remove ice. Once defrosted, clean and dry the interior before restarting.

6. Solução De Problemas

Antes de contatar o serviço de assistência técnica, verifiqueview Os seguintes problemas comuns e suas soluções:

ProblemaPossível causaSolução
A unidade não funcionaNo power to the unit; circuit breaker tripped; power cord unplugged.Check power supply, circuit breaker, and ensure cord is securely plugged in.
A temperatura está muito quenteDoor left open; excessive door openings; unit overloaded; poor ventilation; temperature setting too high.Ensure door is closed; reduce frequency of door openings; do not overload; check ventilation; adjust temperature setting.
Excessive frost buildup (freezer)Porta mal vedada; aberturas frequentes da porta; alta umidade.Check door gasket for damage; ensure door closes completely; perform manual defrost.
Alarme soandoTemperature out of range; door open; power failure; sensor error.Check temperature display; ensure door is closed; verify power supply; contact service if sensor error persists.
Unidade é barulhentaUnit not level; objects vibrating against unit; normal compressor operation.Ensure unit is level; move objects away from unit; some operational noise is normal.

7. Especificações

RecursoEspecificação
MarcaACCUCOLD
Informações do modeloARG6PV-AFZ1PVSTACK
Peso do item150 libras
Dimensões do produto (P x L x A)24.38 x 23.38 x 54.75 polegadas
Capacidade total7.4 Cubic Feet (6 cu.ft. Refrigerator, 1.4 cu.ft. Freezer)
Capacidade de alimentos frescos do refrigerador6 pés cúbicos
Capacidade do congelador1.4 pés cúbicos
Tipo de instalaçãoFreestanding
Fator de formaCompactar
Características especiaisCompact, Door Ajar Alarm, Microprocessor Temperature Control, Remote Alarm Contacts, Probe Port
CorPorta de vidro
Volumetage115 Volts
Sistema de degelo (refrigerador)Adjustable Cycle Defrost (Auto)
Sistema de degelo (congelador)Manual
Dobradiças de portaRight (RHD)
Tipo de material da portaVidro
Tipo de prateleiraArame
Número de prateleiras4
CertificaçãoETL
Componentes incluídosAll-Refrigerator/All-Freezer Combination
Número de portas2

8. Garantia e Suporte

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official ACCUCOLD website. Ensure you have your model number (ARG6PV-AFZ1PVSTACK) and serial number ready when contacting support.

Documentos relacionados - ARG6PV-AFZ1PVSTACK

Préview AccuCold CP133 Medical Refrigerator/Freezer Instruction Manual
Instruction manual for the AccuCold CP133 9.5 cu.ft. general purpose medical refrigerator/freezer by Summit Appliance. Covers safety, installation, operation, maintenance, troubleshooting, and warranty.
Préview Accucold ACR45L & ACF33L Frost-Free Refrigerator and Freezer Instruction Manual
Accucold ACR45L Frost-Free Refrigerator and ACF33L Frost-Free Freezer instruction manual from Felix Storch, Inc. Covers installation, operation, safety, and maintenance for these refrigeration appliances.
Préview Accucold Medical Refrigerators User Manual
Comprehensive user manual for Accucold medical refrigerators, detailing safety guidelines, installation procedures, operational controls, temperature management, troubleshooting, technical specifications, and warranty information.
Préview Accucold Medical Refrigerators User Manual
Comprehensive user manual for Accucold Medical Refrigerators, covering safety, installation, operation, troubleshooting, and warranty information. Includes details on models ARS and ARG series.
Préview Accucold FS407LBI7MEDADA Commercial Counter All-Freezer Specifications
Detailed specifications and features for the Accucold FS407LBI7MEDADA, a 2.8 cu.ft. commercially listed counter all-freezer designed for built-in or freestanding use, featuring ADA compliance, high temperature alarm, and ETL-S listing.
Préview Manual do Usuário de Refrigeradores e Congeladores Verticais AccuCold
Manual do usuário completo para refrigeradores e congeladores verticais AccuCold, abrangendo instalação, operação, manutenção, solução de problemas e informações sobre a garantia. Inclui diretrizes de segurança e especificações do modelo.