NJTY T3

NJTY T3 Multimeter Instruction Manual

Modelo: T3

Introdução

This manual provides detailed instructions for the safe and effective use of the NJTY T3 Digital Multimeter. Please read this manual thoroughly before operation and retain it for future reference. The NJTY T3 is a rechargeable, auto-ranging digital multimeter designed for accurate measurements of AC/DC voltage, resistance, and features Non-Contact Voltage (NCV) detection and live wire testing.

NJTY T3 Multimeter with probes and charging cable

Image: The NJTY T3 Digital Multimeter, showing its main unit, red and black test probes, and a USB-C charging cable connected.

Informações de segurança

Always adhere to safety precautions when using any electrical testing equipment. Failure to do so may result in injury or damage to the device.

Conteúdo da embalagem

Verifique se todos os itens estão presentes na embalagem:

Configurar

1. Carregamento inicial

The NJTY T3 Multimeter features a built-in rechargeable Lithium Ion battery. Before first use, or if the low battery indicator is displayed, charge the device using the provided Type-C charging cable.

  1. Conecte a extremidade Tipo C do cabo de carregamento à porta de carregamento do multímetro.
  2. Connect the USB-A end of the charging cable to a standard USB power adapter (not included) or a computer's USB port.
  3. The charging indicator on the multimeter will illuminate during charging and turn off when fully charged.
NJTY T3 Multimeter connected to a laptop via Type-C charging cable

Image: The NJTY T3 Multimeter being charged via its Type-C port, connected to a laptop.

2. Conectando cabos de teste

Insert the red test lead into the "VΩ" input jack and the black test lead into the "COM" input jack. Ensure they are securely seated.

Instruções de operação

The NJTY T3 Multimeter features an auto-ranging function, simplifying operation by automatically detecting the measurement type and range.

1. Ligar/desligar

Press and hold the power button to turn the multimeter on or off. The device will automatically shut off after approximately 15 minutes of inactivity to conserve battery life.

2. Automatic Measurement (Auto-Ranging)

In auto-ranging mode, the multimeter will automatically identify and measure AC voltage, CC voltage, or resistance when the test leads are applied to a circuit. The display will show the measurement type (AC, DC, Ω) and the value.

NJTY T3 Multimeter displaying 'Auto function scan' with icons for various measurement modes

Image: The NJTY T3 Multimeter screen showing "Auto function scan" and icons representing AC/DC voltage, resistance, continuity, NCV, and flashlight functions.

3. AC / DC Voltage Medição

  1. Certifique-se de que o multímetro esteja ligado.
  2. Connect the test leads to the circuit points where voltage needs to be measured. The multimeter will automatically detect AC or DC voltage.
  3. Leia o vol.tagO valor exibido na tela.
NJTY T3 Multimeter performing AC and DC voltage testes

Image: Two separate images showing the NJTY T3 Multimeter measuring AC voltage from a power strip and DC voltage from a 9V battery.

4. Medição de resistência

  1. Importante: Certifique-se de que o circuito esteja desenergizado antes de medir a resistência.
  2. Connect the test leads across the component or circuit section where resistance is to be measured.
  3. The multimeter will display the resistance value in Ohms (Ω), Kilo-Ohms (KΩ), or Mega-Ohms (MΩ).
NJTY T3 Multimeter performing resistance and continuity tests

Image: Two separate images showing the NJTY T3 Multimeter measuring resistance of a resistor and performing a continuity test on a wire.

5. Volume sem contatotage (NCV) Detecção

The NCV function allows for safe detection of live wires without direct contact.

  1. Press the NCV button (if available, or ensure NCV mode is active).
  2. Bring the NCV sensor at the top of the multimeter close to the wire or outlet.
  3. The multimeter will emit an audible beep and the display will indicate the presence of AC voltage, with increasing intensity as it gets closer to the source.
NJTY T3 Multimeter performing NCV detection near an electrical outlet

Image: The NJTY T3 Multimeter detecting non-contact voltage near an electrical wall outlet, with the screen showing "EF" and a signal strength indicator.

6. Teste de Fios Energizados

Essa função ajuda a identificar fios energizados em um circuito de corrente alternada.

  1. Insert the red test probe into the socket or touch it to the wire you want to test.
  2. If the multimeter emits an alarm sound and the screen changes to indicate "LIVE", it signifies a live wire.
NJTY T3 Multimeter performing live wire testing on an electrical outlet

Image: The NJTY T3 Multimeter's red probe inserted into an electrical outlet for live wire testing, with the screen displaying "LIVE".

7. Teste de Continuidade

  1. Importante: Certifique-se de que o circuito esteja desenergizado antes de realizar um teste de continuidade.
  2. Connect the test leads across the component or wire to be tested.
  3. If continuity exists (resistance is low, typically below 50Ω), the multimeter will emit an audible beep.

8. Dados em espera

Pressione o botão "HOLD" para congelar a leitura atual no visor. Pressione-o novamente para liberar a função de retenção.

9. Lanterna e luz de fundo

The multimeter includes a built-in flashlight for illuminating the test area and a backlight for the display, enhancing visibility in low-light conditions. Refer to the device buttons for activation (typically a short press of the power button or a dedicated light button).

NJTY T3 Multimeter with flashlight illuminated

Image: The NJTY T3 Multimeter with its integrated flashlight active, illuminating a dark electrical panel.

Manutenção

1. Limpeza

Wipe the multimeter's case with a damp Use um pano e detergente neutro. Não utilize abrasivos ou solventes. Certifique-se de que o aparelho esteja desligado e desconectado de qualquer fonte de energia antes de limpá-lo.

2. Cuidados com a bateria

The built-in Lithium Ion battery should be charged regularly, especially if the device is not used for extended periods. The automatic shut-off feature helps prolong battery life. A low battery indicator will appear on the display when charging is required.

NJTY T3 Multimeter displaying a low battery warning

Image: The NJTY T3 Multimeter screen showing a low battery warning icon, indicating the need for recharging.

3. Armazenamento

Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. Disconnect test leads when storing.

Solução de problemas

ProblemaPossível causaSolução
O monitor não liga e o dispositivo não funciona.Bateria fraca ou dispositivo desligado.Charge the battery using the Type-C cable. Press and hold the power button to turn on.
Leituras imprecisas.Poor test lead connection, incorrect measurement technique, or exceeding input limits.Ensure test leads are firmly connected. Review operating instructions for correct measurement procedures. Do not exceed specified input ranges.
Multimeter automatically shuts off.Automatic power-off feature activated due to inactivity.This is normal behavior to conserve battery. Press the power button to turn it back on.
NCV detection not working or inconsistent.Distance to voltage source too far, or interference.Bring the NCV sensor closer to the suspected live wire. Ensure no other strong electromagnetic fields are present.

Especificações

RecursoDetalhe
Mostrar4000 contagens, LCD colorido de 3.19 polegadas
Vol. DCtage Alcance0.8V - 600V (Accuracy: ±(0.8%+5))
Vol. CAtage Alcance1V - 600V (Accuracy: ±(1.0%+5))
Faixa de resistência0 - 40MΩ (Accuracy: ±(1.0%+10))
Minimum Resolution (DCV/ACV)0.001V
Minimum Resolution (Resistance)
Fonte de energiaBateria recarregável de íon de lítio (incluída)
Porta de carregamentoTipo C
Desligamento automáticoApproximately 15 minutes of inactivity
LanternaYes (1 minute auto shut-off)
Luz de fundoSim
CampainhaYes (for continuity, internal resistance less than 50Ω)
Detecção de NCVSim
RMS verdadeiroYes (45Hz-2KHz)
Indicador de bateria fracaSim
Identificação de fio energizadoSim
Dimensões do produto5.51 x 1.18 x 0.79 polegadas
Peso do item150 gramas (5.29 onças)
NJTY T3 Multimeter NCV detection and detailed specifications table

Image: The NJTY T3 Multimeter demonstrating NCV detection alongside a table detailing its technical specifications.

Garantia e Suporte

Informações de garantia

For specific warranty terms and conditions, please refer to the warranty card included with your product or contact the seller directly. Warranty coverage typically addresses manufacturing defects under normal use.

Suporte ao cliente

If you encounter any issues or have questions regarding the NJTY T3 Multimeter, please contact your retailer or the manufacturer's customer support channel. Refer to the "after-sales channel" information provided in your product packaging for contact details.

Documentos relacionados - T3

Préview NJTY T21L LCR Meter: Auto-ranging Digital Multimeter with TRUE RMS - User Manual
User manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers features, safety, technical specifications, and operation for accurate electrical measurements.
Préview NJTY T21L LCR Meter: Auto-ranging Digital Multimeter with TRUE RMS - User Manual
Comprehensive user manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers specifications, safety, operation, and measurement functions for voltage, current, resistance, capacitance, inductance, frequency, and temperature.
Préview Guia do usuário do multímetro de ponteiro NJTY: recursos, especificações e instruções
Guia do usuário abrangente para o multímetro de ponteiro NJTY, detalhando sua aparência, especificações, funções de medição (voltagem CC/CA)tage, corrente, resistência, capacitância, etc.) e lembretes importantes de segurança.
Préview NJTY S18D Digital Multimeter User Manual
User manual for the NJTY S18D Digital Multimeter, detailing safety instructions, panel indications, operational guidelines, and technical specifications for accurate electrical measurements. Features include IEC-61010 compliance, backlit LCD, True RMS, and auto-ranging.
Préview NJTY 88 Series Analog Multimeter: User Manual & Technical Guide
Comprehensive user manual for the NJTY 88 series analog multimeters, covering features, specifications, safety precautions, and measurement instructions for DC/AC voltage and current, resistance, capacitance, frequency, and more.
Préview NJTY T60 Series Insulation Resistance Tester Instruction Manual
Detailed instruction manual for NJTY T6005, T6010, and T6015 analog insulation resistance testers, covering features, operation, safety, technical specifications, and package contents.