Dasqua 4710-1205

Manual do Usuário do Conjunto de Medidores de Profundidade Eletrônicos Dasqua 4710-1205 com 7 Peças (0-16 Polegadas)

Modelo: 4710-1205

1. Introdução

This manual provides instructions for the proper use and maintenance of the Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, model 4710-1205. This electronic depth gage is designed for precise depth measurements in various industrial and scientific applications. It features a digital display for clear readings and is constructed for durability and accuracy.

Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set

Image 1.1: The Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, showing the main unit and various measurement rods.

2. Conteúdo da embalagem

Verifique se todos os componentes estão presentes na embalagem:

  • Electronic Depth Gage Unit
  • Set of Measurement Rods (7 pieces)
  • Estojo de armazenamento
  • Warranty Letter
Contents of the Dasqua Depth Gage Set package

Image 2.1: The complete Dasqua Electronic Depth Gage Set, including the main unit, measurement rods, and storage case.

3. Principais características

  • Resolução: 0.0005-inch / 0.01mm for precise measurements.
  • Conformidade padrão: Manufactured in accordance with DIN863 standards.
  • Fuso: Hardened, ground, and lapped for enhanced accuracy.
  • Versatilidade: Designed to accommodate a broad range of measurement applications.
  • Mostrar: Large, digital display for clear and quick readings.
  • Construção: Hardened stainless steel base and rods resist wear, ensuring durability and consistent accuracy.
  • Redefinição zero: Ability to reset to zero at any position for comparative depth measurements.

4. Instruções de configuração

4.1. Instalação da bateria

The electronic depth gage typically uses a CR2032 lithium coin cell battery. To install or replace the battery:

  1. Localize a tampa do compartimento da bateria na parte traseira da unidade de exibição digital.
  2. Use uma pequena chave de fenda ou uma moeda para abrir a tampa.
  3. Insira uma nova bateria CR2032 com o lado positivo (+) voltado para cima.
  4. Recoloque a tampa do compartimento da bateria com segurança.

4.2. Attaching Measurement Rods

Select the appropriate measurement rod for the desired depth range. The set includes rods of various lengths.

  1. Identify the threaded end of the measurement rod.
  2. Carefully screw the rod into the threaded hole at the bottom of the depth gage's base until it is finger-tight. Do not overtighten.
  3. Ensure the rod is securely attached and straight.
Dasqua Depth Gage with a measurement rod attached

Image 4.1: The electronic depth gage with a measurement rod properly attached to its base.

Various measurement rods included in the set

Image 4.2: A selection of the hardened stainless steel measurement rods provided with the depth gage set.

5. Instruções de operação

5.1. Ligar/desligar

  • Pressione o LIGADO/DESLIGADO botão para ligar o dispositivo.
  • Pressione o LIGADO/DESLIGADO Pressione o botão novamente para desligar o dispositivo.

5.2. Unit Conversion (Inch/Millimeter)

  • Pressione o mm/pol. button to switch between millimeter (mm) and inch (in) units. The selected unit will be displayed on the screen.

5.3. Zero Setting

The zero-reset function allows for comparative measurements or setting a reference point.

  1. Place the depth gage on a flat, stable reference surface, ensuring the measurement rod is fully retracted or resting on the surface.
  2. Pressione o ZERO botão. O visor mostrará '0.000' ou '0.00'.

5.4. Fazendo uma medição

  1. Ensure the depth gage is zeroed on a reference surface.
  2. Place the base of the depth gage firmly on the surface from which the depth is to be measured.
  3. Lower the measurement rod into the hole or recess until its tip contacts the bottom.
  4. Leia a medição diretamente no visor digital.

5.5. Função Hold

  • Pressione o SEGURAR Botão para congelar a leitura atual no visor.
  • Pressione o SEGURAR Pressione o botão novamente para liberar a leitura e retornar à medição em tempo real.
Close-up of the digital display and control buttons on the depth gage

Imagem 5.1: Detalhada view of the digital display, showing the ON/OFF, mm/in, HOLD, and ZERO buttons.

6. Manutenção

6.1. Limpeza

  • Wipe the depth gage and rods with a clean, dry, lint-free cloth after each use.
  • Para sujeira persistente, use um pano levemente umedecido.ampened with isopropyl alcohol. Avoid harsh chemicals or solvents.
  • Ensure no liquid enters the electronic components.

6.2. Armazenamento

  • Store the depth gage in its protective case when not in use.
  • Keep the device in a dry environment, away from direct sunlight, extreme temperatures, and high humidity.
  • Se for armazenar o aparelho por um período prolongado, remova a bateria para evitar vazamentos.

6.3. Substituição da bateria

Replace the battery when the display becomes dim or erratic. Refer to Section 4.1 for battery installation instructions.

7. Solução De Problemas

  • A tela está em branco ou com brilho reduzido:
    Check battery installation. Replace the battery if necessary. Ensure the device is powered on.
  • Leituras imprecisas:
    Ensure the depth gage is properly zeroed on a flat reference surface. Clean the measurement rod and base to remove any debris. Verify the measurement rod is securely attached.
  • Botões não respondem:
    Verifique o nível da bateria. Se o problema persistir após a substituição da bateria, entre em contato com o suporte ao cliente.

8. Especificações do produto

EspecificaçãoDetalhe
Número do modelo4710-1205
Faixa de medição0-16 polegadas / 0-400 mm
Resolução0.0005 polegadas / 0.01 mm
Precisão0.0015 polegadas / 0.03 mm
MaterialHardened Stainless Steel
Fonte de energiaCR2032 Battery (typical)
Dimensões da embalagem9 x 5 x 2 polegadas
Peso do item12.8 onças
Technical specifications and diagram for Dasqua Depth Gage Set

Image 8.1: Detailed specifications and dimensional diagram for the Dasqua 0-16 inch Electronic Depth Gage Set.

9. Garantia e Suporte

This product is supplied with a warranty letter. For specific warranty terms and conditions, please refer to the documentation included in your package. For technical support, service, or inquiries regarding your Dasqua 4710-1205 Electronic Depth Gage Set, please contact the manufacturer directly through their official website ou canais de atendimento ao cliente.

Documentos relacionados - 4710-1205

Préview Micrômetro Digital Externo Dasqua: Instruções e Especificações do Produto
Instruções detalhadas do produto e especificações para o Micrômetro Digital Externo Dasqua, abrangendo sua estrutura, teclas, visor LCD, operação, requisitos de energia, precauções de segurança e guia de solução de problemas.
Préview Medidor digital indicador com codificador linear - Informações de segurança e técnicas
Instruções de segurança, diretrizes de manuseio e especificações técnicas para o medidor indicador digital DASQUA com codificador linear (modelos DQ-25001, DQ-25002).
Préview Manual de instruções do paquímetro Dasqua Vernier/Dial Caliper
Manual de instruções para paquímetros Dasqua Vernier e Dial Calipers, abrangendo estruturas, leitura de medidas, uso comum, uso especial do paquímetro, precauções e solução de problemas.
Préview Instruções e guia de uso do paquímetro digital Dasqua IP67
Instruções completas do produto para o paquímetro digital Dasqua IP67. Este guia abrange diretrizes de desempenho, precauções de segurança, especificações detalhadas, instruções de uso, substituição da bateria, solução de problemas e métodos de descarte adequados para uma operação precisa e segura.
Préview Micrômetro digital externo à prova d'água Dasqua IP65: instruções do produto
Instruções completas do produto para o micrômetro digital externo à prova d'água Dasqua IP65, abrangendo uso, estrutura, botões, bateria, solução de problemas e precauções.
Préview Manual de instruções do medidor digital Dasqua
Manual de instruções do medidor digital Dasqua, detalhando as etapas de uso, características do produto, especificações e cuidados importantes. Inclui os números de modelo TD230A, TD230B e TD230C.