1. Introdução

This manual provides detailed instructions for the installation, operation, and maintenance of the RAB Lighting B17 LED Bollard Light. This outdoor luminaire features field-adjustable wattage and selectable color temperature (CCT), designed for various outdoor applications.

Os principais recursos incluem:

RAB Lighting B17 LED Bollard Light

Figure 1: RAB Lighting B17 LED Bollard Light (Model B17D shown).

2. Informações de segurança

AVISO: Risco de choque elétrico. Desligue a energia antes da instalação ou manutenção. A instalação deve ser realizada por um eletricista qualificado, em conformidade com todas as normas elétricas nacionais e locais aplicáveis.

3. Conteúdo da embalagem

Verifique se todos os componentes estão presentes antes de iniciar a instalação:

4. Configuração e instalação

Follow these steps for proper installation of the B17 LED Bollard Light:

  1. Prepare o local de instalação: Ensure the mounting surface is stable and level. Run electrical conduit and wiring to the desired location according to local codes.
  2. Desconecte a energia: Desligue a energia no disjuntor antes de iniciar qualquer trabalho elétrico.
  3. Mount the Bollard: Secure the bollard base to the mounting surface using appropriate hardware. Ensure a watertight seal if required by local codes.
  4. Faça conexões elétricas: Connect the fixture's wires to the supply wires. Follow standard wiring practices:
    • Black to Line (L)
    • Branco a Neutro (N)
    • Green/Ground to Ground (G)
    • Purple to Dimming (+) (for 0-10V dimming)
    • Gray to Dimming (-) (for 0-10V dimming)
    Certifique-se de que todas as conexões estejam seguras e isoladas.
  5. Selecione Wattage e CCT: Before closing the fixture, adjust the wattage and CCT switches located inside the fixture head. Refer to Section 5 for details.
  6. Secure the Fixture Head: Attach the fixture head to the bollard body, ensuring all seals are properly seated to maintain the wet location rating.
  7. Restaurar energia: Turn on power at the circuit breaker and test the light.
UL Listed and Wet Location Rated symbols

Figure 2: The B17 Bollard Light is UL Listed and rated for wet locations, ensuring durability in outdoor environments.

5. Instruções de operação

5.1. Field-Adjustable Wattage

The B17 bollard light allows you to select the desired wattage output to optimize brightness and energy consumption. A switch located inside the fixture head enables selection between 24W, 19W, and 14W.

Para ajustar: Disconnect power. Open the fixture head. Locate the wattage selection switch and move it to the desired setting. Close the fixture head and restore power.

5.2. Selectable Color Temperature (CCT)

The fixture offers three color temperature options to suit different aesthetic preferences and applications. A separate switch inside the fixture head allows selection between 3000K, 4000K, and 5000K.

Para ajustar: Disconnect power. Open the fixture head. Locate the CCT selection switch and move it to the desired setting. Close the fixture head and restore power.

Image showing 14W, 19W, 24W wattage options and 3000K, 4000K, 5000K CCT options for the bollard light

Figure 3: Visual representation of adjustable wattage and selectable CCT settings.

5.3. 0-10V Dimming

The B17 bollard light is compatible with 0-10V dimming systems. Connect the purple and gray dimming wires to a compatible 0-10V dimmer control. This allows for smooth adjustment of light output from 100% down to 10% (or lower, depending on dimmer specifications).

Ensure the dimmer is rated for LED loads and is compatible with 0-10V dimming protocols.

6. Manutenção

The B17 LED Bollard Light is designed for minimal maintenance due to its long LED lifespan of 50,000 hours.

Image indicating a 50,000-hour lifespan for the LED bollard light

Figure 4: The B17 LED Bollard Light offers a long 50,000-hour operational lifespan.

7. Solução De Problemas

ProblemaPossível causaSolução
A luz não acende.Sem fonte de alimentação.
Conexão de fiação solta.
O que está incorretotage/CCT setting.
Check circuit breaker. Ensure power is on.
Verifique se todas as conexões dos fios estão seguras (desligue a energia primeiro).
Confirmar wattage/CCT switches are set correctly.
A luz pisca ou escurece inesperadamente.Dimmer incompatível.
Loose dimming wire connection.
Volumetage flutuações.
Ensure 0-10V dimmer is compatible with LED loads.
Check purple and gray dimming wire connections.
Consulte um eletricista para verificar a estabilidade do fornecimento de energia.
A intensidade da luz está muito baixa/alta.O que está incorretotage configuração.Ajuste o wattage selection switch inside the fixture head (power off first).
Cores claras não são desejáveis.Configuração incorreta do CCT.Adjust the CCT selection switch inside the fixture head (power off first).

8. Especificações

RecursoDetalhe
Nome do modeloB17
MarcaIluminação RAB
O quetageField-Adjustable: 24W / 19W / 14W
Temperatura de cor (CCT)Selecionável: 3000K / 4000K / 5000K
Escurecimento0-10V Dimerizável
Vida útil50,000 horas
MaterialMetal body, Glass shade
Classificação AmbientalCertificado pela UL para locais úmidos.
Componentes incluídosChave liga-desliga
UPC192552028424
ASINB0DY2FPPNS

9. Garantia e Suporte

For warranty information and technical support, please contact RAB Lighting directly. Refer to the official RAB Lighting webPara obter informações específicas sobre os termos da garantia e detalhes de contato, consulte o site ou a documentação de compra.

RAB Lighting Contact: www.rablighting.com