1. Introdução
The DIGITEN THT1032 is a versatile temperature and humidity controller designed for precise environmental management. It features three independent outlets for controlling heating/cooling, humidification/dehumidification, and timed operations. Equipped with dual high-precision probes, this device is suitable for various applications including reptile enclosures, mushroom cultivation, plant seeding, and home brewing.
2. Principais características
- Operação Plug & Play: Simple setup with intuitive buttons for quick configuration.
- Dual High-Precision Probes: Separate probes for temperature (accuracy: ±0.4°C/±0.7°F) and humidity (accuracy: ±3%).
- Triple-Zone Precision Control: Three independent outlets for temperature, humidity, and timed devices.
- Grande display LCD: Clear, real-time monitoring with switchable Fahrenheit/Celsius units.
- Climate Customization: Combine heating/cooling with humidification/dehumidification, and program the third outlet for timers.
3. Conteúdo da embalagem
- DIGITEN THT1032 Controller Unit
- Sonda de temperatura
- Sonda de Umidade
- Manual do usuário
4. Produto acabadoview
The DIGITEN THT1032 controller features a main unit with a large LCD display, control buttons, three power outlets, and two external probes for temperature and humidity sensing.

Imagem 1: Frente view of the DIGITEN THT1032 controller, showing the display, buttons, and three power outlets.
4.1. Painel de controle e exibição
The front panel includes an LCD screen and four control buttons: SET, MODE, Up (▲), and Down (▼).

Imagem 2: Detalhada view of the controller's outlets and control buttons. OUT1 is for temperature, OUT2 for humidity, and OUT3 for timer functions.
- Botão de configuração: Used to select an outlet for configuration or confirm settings.
- Botão MODE: Used to change the operating mode (e.g., heating/cooling, humidification/dehumidification, timer program).
- Botão para cima (▲): Aumenta os valores ou navega pelas opções do menu.
- Botão para baixo (▼): Diminui os valores ou navega pelas opções do menu.
- SAÍDA1: Temperature controlled outlet.
- SAÍDA2: Humidity controlled outlet.
- SAÍDA3: Timer controlled outlet.
4.2. Sondas
The controller comes with two separate probes: one for temperature and one for humidity. These probes are essential for accurate environmental monitoring.

Image 3: The temperature probe (left) and humidity probe (right) connected to the controller, illustrating their distinct functions.
5. Configuração inicial
- Conectar sondas: Plug the temperature probe and humidity probe into their respective ports on the controller. Ensure they are securely connected.
- Colocação: Position the probes in the environment you wish to monitor and control. Ensure they are not directly exposed to heat sources, moisture, or airflow that could skew readings.
- Ligar: Plug the controller into a standard 120V AC power outlet. The display will illuminate, showing current temperature, humidity, and time.
- Conectar dispositivos: Plug your heating/cooling device into OUT1, your humidification/dehumidification device into OUT2, and any timed appliance (e.g., lights, misters) into OUT3.
6. Instruções de operação
6.1. Setting Temperature Control (OUT1)
- Pressione o DEFINIR button repeatedly until OUT1 is selected (indicated by a flashing OUT1 icon or similar).
- Use o Para cima (▲) or Para baixo (▼) botões para ajustar a temperatura alvo desejada.
- Imprensa MODO to cycle through heating (HEAT) or cooling (COOL) modes. Select the appropriate mode for your connected device.
- Imprensa DEFINIR to confirm the temperature and mode.
- To set the temperature differential (hysteresis), press and hold DEFINIR for a few seconds when OUT1 is selected. Use Para cima/para baixo to adjust the difference between the set point and when the device turns on/off. Press DEFINIR para confirmar.
6.2. Setting Humidity Control (OUT2)
- Pressione o DEFINIR button repeatedly until OUT2 is selected.
- Use o Para cima (▲) or Para baixo (▼) buttons to adjust the desired target humidity percentage.
- Imprensa MODO to cycle through humidification (HUMIDIFICATION) or dehumidification (DEHUMIDIFICATION) modes. Select the appropriate mode.
- Imprensa DEFINIR to confirm the humidity and mode.
- To set the humidity differential, press and hold DEFINIR for a few seconds when OUT2 is selected. Use Para cima/para baixo Para ajustar. Pressione DEFINIR para confirmar.
6.3. Setting Timer Control (OUT3)
- Pressione o DEFINIR button repeatedly until OUT3 is selected.
- Imprensa MODO to enter the timer programming interface.
- Usar Para cima (▲) or Para baixo (▼) to set the ON time (hour and minute). Press DEFINIR para passar para a próxima configuração.
- Set the OFF time (hour and minute) using Para cima/para baixo e DEFINIR.
- The controller supports multiple ON/OFF programs for OUT3. Refer to the on-screen prompts for additional program slots.
- Imprensa DEFINIR to save and exit the timer settings.
6.4. Conversão de unidades de temperatura (°C/°F)
To switch between Celsius and Fahrenheit, press and hold the Para cima (▲) button for approximately 3 seconds. The display will change accordingly.
7. Manutenção
- Limpeza: Limpe a unidade controladora com um pano macio e seco. Não utilize produtos de limpeza abrasivos nem mergulhe a unidade em água.
- Cuidados com a sonda: Keep the probes clean and free from debris. Avoid bending or damaging the probe cables. If probes become dirty, gently clean them with a damp cloth and allow them to dry completely before re-use.
- Armazenar: Quando não estiver em uso, guarde o controlador em local fresco e seco, longe da luz solar direta e de temperaturas extremas.
8. Solução De Problemas
| Emitir | Possível causa | Solução |
|---|---|---|
| Display is blank or not powering on. | Sem alimentação elétrica; conexão solta. | Ensure the controller is securely plugged into a live power outlet. Check the power source. |
| OUT1/OUT2/OUT3 not activating connected device. | Incorrect settings; device malfunction; power issue. | Verify temperature/humidity/timer settings. Check if the connected device is working independently. Ensure the controller's set point is met for activation. |
| Humidity probe shows "ERR" reading. | Probe malfunction; damaged cable; sensor error. | Check the humidity probe connection. Inspect the probe cable for damage. If the error persists, the probe may need replacement. |
| Leituras imprecisas de temperatura/umidade. | Probe placement; dirty probe; probe malfunction. | Relocate probes away from direct heat/moisture/airflow. Clean probes gently. If issues persist, consider probe replacement. |
9. Especificações técnicas
| Especificação | Valor |
|---|---|
| Número do modelo | THT1032 |
| Requisitos de energia | 100-240 VCA |
| Capacidade de carga | 10A per outlet (1100W@110V, 2200W@220V) |
| Faixa de controle de temperatura | -10°C a 120°C / 14°F a 248°F |
| Precisão da temperatura | ± 0.4 ° C / ± 0.7 ° F |
| Precisão de umidade | ±3% |
| Tipo de sensor de sonda | Digital Signal Output, I2C Interface |
| Temperatura do ambiente operacional | 0-50°C / 32-122°F |
| Operating Environment Relative Humidity | <85% |
| Tipo de exibição | LCD |
| Material | Plástico |
| Cor | Cinza |
| Peso do item | 1.04 libras |
| Dimensões da embalagem | 6.85 x 6.34 x 1.93 polegadas |
10. Garantia e Suporte ao Cliente
DIGITEN provides a one-year warranty for any quality-related issues with this product. For technical assistance, troubleshooting, or warranty claims, please contact DIGITEN customer support through the retailer where the product was purchased or visit the official DIGITEN website para informações de contato.
Guarde o comprovante de compra para fins de assistência em garantia.