1. Introdução
This manual provides essential information for the safe operation, maintenance, and troubleshooting of your Redact RT002i 2400W Portable Inverter Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.

Figure 1: Redact RT002i 2400W Portable Inverter Generator
2. Informações de segurança
AVISO: Perigo de Monóxido de Carbono
Usar um gerador em ambientes fechados PODE MATAR VOCÊ EM MINUTOS. O escapamento do gerador contém monóxido de carbono. Este é um veneno que você não pode ver ou cheirar. NUNCA use dentro de uma casa ou garagem, MESMO SE as portas e janelas estiverem abertas. Use SOMENTE FORA e longe de janelas, portas e saídas de ar.
- Always operate the generator in a well-ventilated outdoor area.
- Mantenha crianças e animais de estimação afastados do gerador durante o funcionamento.
- Certifique-se de que o gerador esteja colocado em uma superfície nivelada.
- Do not refuel while the engine is running or hot. Allow the generator to cool before adding fuel.
- Wear appropriate personal protective equipment (PPE) when handling fuel or performing maintenance.
- The generator is equipped with a CO Shield technology that automatically shuts down the engine if dangerous carbon monoxide levels are detected. Do not bypass this safety feature.
3. Conteúdo da embalagem
Verifique se todos os itens estão presentes na embalagem:
- Redact RT002i Inverter Generator
- Manual do Proprietário
- Chave de vela de ignição
- Funil de óleo
- Cabo de carregamento CC
- Parallel Cables (if included with specific model variant)
4. Identificação do componente

Figura 2: Painel de Controleview
- Interruptor do modo ECO: Engages or disengages Eco Mode for fuel efficiency.
- V.F.R.T. Display: Digital meter showing Voltage, Frequency, Run Time, etc.
- AC 120V 20A Duplex Outlets: Tomadas domésticas padrão.
- USB Type-A & Type-C Ports: Para carregar dispositivos eletrônicos.
- CO Alert Indicator: Lights up if carbon monoxide is detected.
- Indicador de óleo baixo: Lights up when oil level is low.
- Indicador de sobrecarga: Lights up if the generator is overloaded.
- Indicador de saída: Green light indicates power output is stable.
- Porta Paralela: Para conectar dois geradores compatíveis e aumentar a potência.
- Botão de reinicialização CA: Reinicia o disjuntor do circuito CA.
- Terminal de aterramento: Para o aterramento adequado do gerador.
- Starting Handle: Used for manual recoil start.
- Three-in-one Switch Knob: Controls engine Off/On/Choke.
5. Configuração
5.1 Adicionando Óleo do Motor
The generator is shipped without engine oil. You must add the correct amount of oil before first use.
- Coloque o gerador em uma superfície nivelada.
- Remove the side maintenance cover (usually secured by screws).
- Locate the oil fill cap/dipstick. Remove it.
- Using the provided oil funnel, slowly add 10W-30 engine oil until it reaches the upper mark on the dipstick. Do not overfill.
- Replace the oil fill cap/dipstick and the maintenance cover.
5.2 Adição de Combustível
Use somente gasolina nova e sem chumbo com octanagem 87 ou superior.
- Ensure the generator is turned OFF and has cooled down.
- Unscrew the fuel cap located on top of the generator.
- Carefully pour gasoline into the fuel tank. Do not overfill. Leave some space for fuel expansion.
- Recoloque a tampa do tanque de combustível firmemente.

Figure 3: Fuel Tank and Runtime
6. Instruções de operação
6.1 Iniciando o gerador
- Ensure the generator is on a level surface and all electrical devices are disconnected.
- Turn the Three-in-one Switch Knob to the 'CHOKE' position.
- Pull the Starting Handle slowly until resistance is felt, then pull firmly and quickly.
- Once the engine starts, slowly move the Three-in-one Switch Knob to the 'ON' position.
- Allow the generator to run for a few minutes to warm up before connecting electrical loads.
6.2 Conectando Dispositivos
Once the generator is running and the Output Indicator light is green, you can connect your electrical devices.
- Plug your devices into the appropriate AC 120V 20A outlets or USB ports.
- Monitor the Overload Indicator. If it lights up, reduce the connected load to prevent damage.
6.3 Modo Eco
The Eco Mode switch allows the generator to automatically adjust engine speed to match the load, improving fuel efficiency and reducing noise levels. For optimal performance and fuel savings, engage Eco Mode when running lighter loads.
6.4 Operação Paralela
For increased power output, two compatible Redact inverter generators can be connected in parallel using a parallel kit (sold separately).

Figure 4: Parallel Operation Setup
- Ensure both generators are turned OFF and cooled.
- Connect the parallel cables to the designated parallel ports on both generators.
- Start both generators individually as per Section 6.1.
- Once both generators are running stably, they will operate in parallel, providing combined power output.
7. Manutenção
Regular maintenance is crucial for the longevity and reliable operation of your generator. Refer to the maintenance schedule in the full owner's manual for detailed intervals.
7.1 Manutenção Geral
- Verifique o nível de óleo do motor: Before each use, check the engine oil level and add if necessary.
- Filtro de ar limpo: Regularly inspect and clean the air filter. Replace if damaged.
- Verifique a vela de ignição: Inspecione a vela de ignição quanto a desgaste e folga adequada. Limpe ou substitua conforme necessário.
- Clean Fuel Filter: Periodically clean or replace the fuel filter.
- Inspecione quanto a danos: Before each use, check for any loose fasteners, fuel leaks, or damaged components.
7.2 Armazenamento
For long-term storage (more than 30 days), follow these steps:
- Drene o tanque de combustível e o carburador.
- Add a fuel stabilizer to the fuel tank if not draining completely. Run the engine for a few minutes to circulate the stabilizer.
- Troque o óleo do motor.
- Remova a vela de ignição e coloque uma pequena quantidade de óleo de motor no cilindro. Puxe a corda de arranque algumas vezes para distribuir o óleo e, em seguida, reinstale a vela de ignição.
- Limpe a parte externa do gerador.
- Guarde o gerador em um local limpo, seco e bem ventilado.
8. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| O motor não pega | Sem combustível Nível baixo de óleo Afogador não ajustado corretamente Problema com a vela de ignição | Adicionar combustível Adicionar óleo Ajustar afogador Inspecione/substitua a vela de ignição |
| Sem saída de energia | Sobrecarga Disjuntor do circuito CA desarmado ECO mode engaged with high load | Reduzir carga Press AC Reset button Disengage ECO mode for higher loads |
| O motor funciona e depois para. | Nível baixo de óleo CO detectado Falta de combustível | Adicionar óleo Move generator to well-ventilated area Adicionar combustível |
| Ruído excessivo | ECO mode off with light load Componentes soltos | Engage ECO mode Check and tighten components |
9. Especificações

Figure 5: Generator Dimensions
| Recurso | Especificação |
|---|---|
| Marca | Redigir |
| Nome do modelo | RT002i |
| Wat começandotage | 2400 Watts |
| Corrida de Águatage | 1800 Watts |
| Tipo de combustível | Gasolina |
| Deslocamento do motor | 79.7 centímetros cúbicos |
| Volume do tanque | 1.1 galões imperiais |
| Tempo de execução (25% de carga) | Até 9 horas |
| Noise Level (23ft, 25% load) | Aproximadamente. 63 dB |
| Peso do item | 40 libras |
| Dimensões do produto | 18.1"C x 11.4"L x 17.9"A |
| Volumetage | 120 Volts |
| Total de tomadas | 5 (2x 120V, 1x USB-A, 1x USB-C, 1x Parallel Port) |
| Características especiais | CO Sensor, Digital Display, Fuel Efficient, Lightweight, Low Oil Shutdown, Parallel Capable |
10. Garantia e Suporte
This Redact RT002i Inverter Generator comes with a 1-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For warranty claims or technical support, please refer to the contact information provided in your full owner's manual or visit the official Redact website.