1. Introdução
The FireAngel FA6812 is a digital carbon monoxide (CO) detector designed to provide reliable protection against the dangers of CO gas. Carbon monoxide is an invisible, odorless, and potentially fatal gas. This device features an electrochemical sensor with a 10-year lifespan and an LCD screen for clear display of CO levels and device status. Early detection and warning are crucial for preventing CO poisoning.

Figure 1: FireAngel FA6812 Carbon Monoxide Detector
This manual will guide you through the installation, operation, and maintenance of your FA6812 detector to ensure optimal performance and safety.
2. Configuração e instalação
2.1 Conteúdo da embalagem
- Alarme de Monóxido de Carbono FireAngel FA6812
- 2 pilhas AA
- Parafusos de montagem e buchas de parede
- Manual do usuário
2.2 Instalação da bateria
The FA6812 detector requires 2 AA batteries for operation. These are included in the package. To install the batteries:
- Localize o compartimento da bateria na parte traseira da unidade.
- Abra a tampa do compartimento da bateria.
- Insira as 2 pilhas AA, certificando-se da polaridade correta (+ e -).
- Feche bem a tampa do compartimento da bateria.
The device will emit a short beep and the LCD will activate, indicating successful battery installation.
2.3 Recomendações de Colocação
For optimal CO detection, consider the following placement guidelines:
- General Placement: Install the detector at mid-height in a room, as carbon monoxide mixes evenly with air. Avoid placing it near the floor or ceiling.
- Proximity to Appliances: Place the detector at least 3 meters (10 feet) away from any fuel-burning appliances (e.g., boilers, gas stoves, fireplaces).
- Áreas para dormir: For maximum protection, install a detector in or near sleeping areas.
- Evite Obstruções: Ensure the detector is not obstructed by furniture, curtains, or other objects that could block the sensor.
- Fatores ambientais: Avoid placing the detector in direct sunlight, in areas of high humidity (e.g., bathrooms), or near ventilation openings.
2.4 Opções de Montagem
The FA6812 can be used freestanding or wall-mounted.
- Independente: The compact and portable design allows the unit to be placed on a flat surface, such as a shelf or table.
- Montagem na parede: Use the integrated mounting bracket and provided screws to securely attach the detector to a wall. Ensure the mounting location adheres to the placement recommendations above.

Figure 2: Product overview com características principais
3. Operação
3.1 LCD Display Indications
The digital LCD screen provides real-time information about the detector's status:
- Modo de espera: Displays the current CO level in parts per million (ppm). If no CO is detected, it will show '0 ppm'.
- Alarme CO: When dangerous CO levels are detected, the screen will display the CO concentration in ppm, accompanied by an audible alarm and a flashing red light.
- "AL" (Alarm in Absence): If a CO alarm triggers while you are away, the device will enter "Alarm in Absence" mode. The screen will display "AL", and the unit will beep every 40 seconds with a red flashing light until deactivated.
- Status da bateria: An icon indicates the battery level. A flashing orange "!" and continuous beep signify low batteries.
- "EOL" (End of Life): This indicator signals that the device has reached the end of its 10-year operational life and needs replacement.

Figure 3: Multifunction LCD Screen
3.2 Ativação de Alarme
In the event of CO detection, the FA6812 will:
- Emit four loud beeps (85 dB(A) at 3m minimum).
- Flash a red LED light.
- Display the CO concentration in ppm on the LCD screen.
Se o alarme tocar:
- Vá imediatamente para um local com ar fresco ao ar livre ou abra todas as portas e janelas.
- Faça uma contagem para verificar se todas as pessoas estão presentes.
- Não retorne ao local até que o alarme tenha parado e a área tenha sido completamente ventilada.
- Seek medical attention for anyone experiencing symptoms of CO poisoning (headache, nausea, dizziness).
- Contact the appropriate emergency services or a qualified technician to investigate the source of the CO.
3.3 Sleep Easy™ Function
The Sleep Easy™ function allows you to temporarily silence the low battery warning for 8 hours. To activate:
- Press and hold the test button when the low battery warning sounds.
During this period, the orange indicator light will continue to flash, and the device remains fully functional for CO detection. This feature is designed for convenience, but batteries should be replaced as soon as possible.

Figure 4: Advanced Functions
4. Manutenção
4.1 Testes regulares
It is recommended to test your CO detector monthly to ensure it is functioning correctly. To perform a test:
- Press and hold the 'TEST' button on the front of the unit.
- The alarm will sound, and the red LED will flash, indicating the alarm is working.
- Release the button to stop the test.
4.2 Substituição da bateria
When the batteries are low, the detector will indicate this with a flashing orange "!" on the LCD and a continuous beep. Replace the batteries immediately to maintain continuous protection. Refer to section 2.2 for battery installation instructions.
4.3 End of Life (EOL) Indication
The FA6812 has a 10-year lifespan. When the device reaches its end of life, the LCD will display "EOL". At this point, the detector should be replaced with a new unit to ensure continued safety.
4.4 Limpeza
Dust and debris can affect the detector's performance. Gently clean the exterior of the unit with a soft, damp cloth. Do not use cleaning agents or solvents, as these can damage the sensor or casing. Do not paint the detector.
5. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| Alarm sounds and LCD shows CO level | Carbon monoxide detected | Follow alarm activation procedures (Section 3.2). Evacuate, ventilate, seek medical help if needed, and identify CO source. |
| Flashing orange "!" and continuous beep | Aviso de bateria fraca | Replace batteries immediately (Section 4.2). Use Sleep Easy™ function if temporary silence is needed. |
| LCD displays "AL" and beeps every 40 seconds | Alarm in Absence triggered | A CO alarm occurred while you were away. Investigate potential CO sources and ventilate the area. |
| LCD displays "EOL" | Fim da vida útil do produto | Replace the detector with a new unit. The sensor is no longer reliable after 10 years. |
| No display or unit unresponsive | No batteries, incorrect battery installation, or faulty unit | Check battery installation and polarity. Replace batteries. If still unresponsive, the unit may be faulty and require replacement. |
6. Especificações
| Recurso | Especificação |
|---|---|
| Número do modelo | FA6812-EUX10 |
| Tipo de sensor | Eletroquímica |
| Vida útil do sensor | 10 anos |
| Fonte de energia | 2 pilhas alcalinas AA (incluídas) |
| Volume do alarme | 85 dB(A) at 3 meters (minimum) |
| Mostrar | LCD digital |
| Dimensões (C x L x A) | 120 x 73 x 35.5 mm |
| Peso | 145 gramas |
| Temperatura de operação | 0°C a 40°C |
| Umidade operacional | 30% a 90% UR (sem condensação) |
| Conformidade | BS EN 50291-1:2018, BS EN 50291-2:2019, CE Marked |
| UPC | 816317006860 |
7. Garantia e Suporte
7.1 Informações de garantia
The FireAngel FA6812 Carbon Monoxide Detector is designed for long-term reliability. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official FireAngel webOs períodos de garantia podem variar conforme a região.
7.2 Suporte ao cliente
If you have any questions, require technical assistance, or need to report an issue with your FireAngel FA6812 detector, please contact FireAngel customer support. Contact details can typically be found on the product packaging or the official FireAngel weblocal (www.fireangeltech.com).