1. Introdução
The FNIRSI FPM-02 is a high-precision 3-in-1 environmental monitor designed for measuring illuminance (lux), temperature, and humidity. It features a 2-inch color display for clear data visualization and is suitable for various professional applications including office lighting assessment, horticulture, laboratories, and photography studios.
2. O que está na caixa
- FNIRSI FPM-02 Environmental Monitor
- Cabo USB
- Estojo de transporte
- Manual do usuário
3. Principais características
- Medição 3 em 1: Monitors Lux, temperature, and humidity simultaneously.
- Tela colorida de 2 polegadas: High-definition display with light and dark theme modes for optimal readability.
- Real-time Data & Curve Recording: Visualizes environmental changes over time.
- Adjustable Alarm Thresholds: Alerts users when measurements exceed set values.
- Rápido SampTaxa de ling: 20Hz (50ms) for real-time monitoring.
- Dual-language Interface: Supports English and Chinese.
- Built-in Sleep Mode & Data Logging: Enhances battery efficiency and usage tracking.

Figure 1: FNIRSI FPM-02 Environmental Monitor with key features highlighted on its color screen.
4. Configuração
4.1 Carregando o dispositivo
- Connect the provided USB cable to the FNIRSI FPM-02's charging port.
- Conecte a outra extremidade do cabo USB a um adaptador de energia USB padrão (não incluído) ou à porta USB de um computador.
- O dispositivo indicará o status de carregamento em sua tela. Uma carga completa normalmente leva de 2 a 3 horas.
4.2 Ligar/Desligar
- To power on: Press and hold the Power button (usually located on the side or front panel) until the screen illuminates.
- Para desligar: Pressione e mantenha pressionado o botão Liga/Desliga até que o dispositivo desligue.
5. Instruções de operação
5.1 Navegando na Interface
The FPM-02 features a user-friendly interface with a 2-inch HD color screen. Use the navigation buttons (up, down, left, right, OK/Enter) to move through menus and select options. The device supports both English and Chinese languages, which can be selected in the settings menu.
5.2 Taking Measurements (Illuminance, Temperature, Humidity)
Upon powering on, the device typically defaults to the main measurement screen, displaying real-time values for illuminance (Lux/FC), temperature (°C/°F), and relative humidity (%).
- Iluminância: Ensure the light sensor (located at the top of the device) is unobstructed and pointed towards the light source or area to be measured. The device will display the light intensity in LUX or FC.
- Temperatura e Umidade: The internal sensors continuously monitor ambient temperature and humidity. Allow a few minutes for readings to stabilize after significant environmental changes.
5.3 Real-time Data and Curve Recording
The device can display real-time data and record changes over time, presenting them as a curve. Access this feature through the main menu to visualize trends and fluctuations in environmental conditions.
5.4 Setting Alarm Thresholds
You can set custom alarm thresholds for Lux, temperature, and humidity. If a measured value exceeds or falls below the set threshold, the device will trigger an alert. Refer to the device's settings menu to configure these thresholds.
5.5 Sleep Mode and Data Logging
To conserve battery, the device features a configurable sleep mode. It also includes data logging capabilities, allowing you to store measurement data for later review and analysis. Consult the user manual for detailed instructions on activating and managing these functions.
6. Manutenção
- Limpeza: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents. Ensure the light sensor and display are kept clean for accurate readings.
- Armazenar: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
- Cuidados com a bateria: Avoid fully discharging the lithium battery frequently. Recharge the device when the battery level is low.
7. Solução De Problemas
| Problema | Possível causa | Solução |
|---|---|---|
| O dispositivo não liga. | Bateria fraca ou descarregada. | Carregue o dispositivo usando o cabo USB fornecido. |
| Leituras imprecisas. | Sensor obstructed or dirty; device not calibrated. | Clean sensors. Ensure proper placement. If issues persist, contact support. |
| A tela não responde. | Falha no software; temperatura extrema. | Restart the device. Ensure operating within specified temperature range. |
8. Especificações técnicas
| Parâmetro | Valor |
|---|---|
| Número do modelo | FPM-02 |
| Faixa de iluminância | 0–1000 / 9999 / 99990 LUX; 10–1000 / 1000 / 10000 FC |
| Resolução de iluminância | 0.1 LUX (0–1000); 0.1 FC (10–1000) |
| Precisão de iluminância | ±(3% + 5 LUX) with standard incandescent lamp (2854°K); ±(6% + 5 LUX) for other light sources |
| Samptempo de espera | 20Hz (50ms) |
| Mostrar | 2″ HD Color Screen |
| Fonte de energia | Bateria de lítio de 3.7 V / 1500 mAh |
| Dimensões do dispositivo | 63 × 28 × 182 mm |
| Peso | 205g |
| Cor | Preto e Azul |
| País de origem | China |
9. Garantia e Suporte
This FNIRSI FPM-02 Environmental Monitor comes with a standard manufacturer's warranty. Please refer to the warranty card included in your package for specific terms and conditions.
For technical support, troubleshooting assistance, or warranty claims, please contact the retailer or manufacturer directly. Keep your purchase receipt as proof of purchase.