L3Campus Stackable Managed Switch
“
Especificações
- Modelo: Omada Campus Stackable L3 Managed Switch
- Front Panel: Mode Selection Button, Management Port, LED,
Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
LIDERADO - Indicação de LED:
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
disconnected or not working properly) - PWR2: Green On (switch powered by PWR1 and PWR2 connected),
Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
devidamente) - LED SYS FAN: Green On (all fans work properly), Yellow On (not
all fans work properly) - MGMT: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port) - MST: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port)
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
Instruções de uso do produto
Capítulo 2: Instalação
Antes de iniciar o processo de instalação, certifique-se de ter todos os
the necessary tools and follow safety precautions.
- Conteúdo da embalagem: Check all items mentioned in
o pacote. - Precauções de segurança: Siga as orientações para
garantir uma instalação segura. - Ferramentas de instalação: Gather all tools required
para instalação. - Instalação do produto: Siga o passo a passo
instructions provided in the manual for successful
instalação.
Capítulo 3: Conexão
After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.
Capítulo 4: Configuração
Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
precisa.
Perguntas frequentes
Q: What should I do if the LED indications show an error?
A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
seção do manual para obter mais assistência.
“`
Solução de rede de negócios
Guia de instalação
Omada Campus Stackable L3 Managed Switch
Sobre este Guia de Instalação
Este Guia de Instalação descreve as características do hardware, os métodos de instalação e os pontos que devem ser observados durante a instalação. Este Guia de Instalação está estruturado da seguinte forma: Capítulo 1 Introdução Este capítulo descreve os componentes externos do switch. Capítulo 2 Instalação Este capítulo ilustra como instalar o switch. Capítulo 3 Conexão Este capítulo ilustra como realizar a conexão física do switch. Capítulo 4 Configuração Este capítulo ilustra como configurar o switch. Apêndice A Solução de Problemas Apêndice B Especificações
Público
Este Guia de Instalação é para:
Engenheiro de Rede
Administrador de rede
Convenções
· Alguns modelos apresentados neste guia podem não estar disponíveis em seu país ou região. Para obter informações sobre vendas locais, visite https://www.omadanetworks.com/.
· As figuras no Capítulo 2, Capítulo 3 e Capítulo 4 são apenas para fins de demonstração. Seu switch pode diferir em aparência daquele retratado.
· Os cálculos de orçamento de PoE são baseados em testes de laboratório. O orçamento real de energia de PoE não é garantido e variará como resultado de limitações do cliente e fatores ambientais.
· Este guia usa os formatos específicos para destacar mensagens especiais. A tabela a seguir lista os ícones de aviso que são usados ao longo deste guia.
Lembre-se de ter cuidado. Um cuidado indica um potencial que pode resultar em danos ao dispositivo.
Lembre-se de tomar conhecimento. A nota contém informações úteis para um melhor aproveitamento do produto.
Documento Relacionado
O Guia do Usuário e o Guia de Referência CLI do produto são fornecidos no Centro de Download. Para obter as informações mais recentes do produto, visite o site oficial website: https://support.omadanetworks.com/document/.
Conteúdo
Capítulo 1 Introdução ———————- 01
1.1 Produto Acimaview …………………………………………………..01 1.2 Aparência…………………………………………………………..01
Capítulo 2 Instalação ———————- 12
2.1 Conteúdo da embalagem ………………………………………………….12 2.2 Precauções de segurança …………………………………………………12 2.3 Ferramentas de instalação………………………………………………..14 2.4 Instalação do produto ………………………………………………..14
Capítulo 3 Conexão ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Capítulo 4 Configuração ——————– 27
4.1 Configuração finalizadaview…………………………………………27 4.2 Modo autônomo……………………………………………………27 4.3 Modo controlador…………………………………………………………28
Apêndice A Solução de problemas —————- 32
Apêndice B Especificações —————— 33
Omada Campus Stackable L3 Managed Switch
Capítulo 1 Introdução
1.1 Produto Acimaview
Projetado para empresas e empresasampus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Exampos arquivos incluem alimentar câmeras de rede, pontos de acesso de LAN sem fio, telefones IP, hubs de rede, computadores integrados, etc.
1.2 Aparência
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Botão de seleção de modo
Porto de Gestão
LIDERADO
Console Port USB2.0 Port (Type-C/RJ45)
Porta 1G RJ45
10G SFP+ Slot LED
The front panel of S6500-48G6XF is shown as the following figure.
Botão de seleção de modo
Porto de Gestão
LIDERADO
Console Port USB2.0 Port (Type-C/RJ45)
Porta 1G RJ45
10G SFP+ Slot LED
Introdução 01
Omada Campus Stackable L3 Managed Switch
Indicação LED
PWR1*
PWR2
Verde Ligado
Desligado
Verde Ligado
Amarelo ativado**
Desligado
Verde Ligado
Desligado
Desligado
Indicação
O switch é alimentado por PWR1. PWR2 está desconectado ou não funciona corretamente.
O switch é alimentado por PWR1. PWR1 e PWR2 estão conectados.*
O switch é alimentado por PWR2. PWR1 está desconectado ou não funciona corretamente.
O switch está desligado ou PWR1 e PWR2 funcionam incorretamente.
LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Quando o LED STK está aceso)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***
Indicação
Piscando: O interruptor funciona corretamente. Ligado ou Desligado: O interruptor funciona incorretamente.
Verde ligado: Todos os ventiladores funcionam corretamente. Amarelo ligado: Nem todos os ventiladores funcionam corretamente.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Verde Ligado: Executando a 1000 Mbps, mas sem atividade. Verde Piscando: Executando a 1000 Mbps e transmitindo ou recebendo dados. Amarelo Ligado: Executando a 10 Mbps/100 Mbps, mas sem atividade. Amarelo Piscando: Executando a 10 Mbps/100 Mbps e transmitindo ou recebendo dados. Desligado: Nenhum dispositivo está vinculado à porta correspondente.
Ativado: O número da porta indica o ID da unidade na topologia de pilha.
Verde Ligado: Executando a 10 Gbps, mas sem atividade. Verde Piscando: Executando a 10 Gbps e transmitindo ou recebendo dados. Amarelo Ligado: Executando a 1 Gbps, mas sem atividade. Amarelo Piscando: Executando a 1 Gbps e transmitindo ou recebendo dados. Desligado: Nenhum dispositivo está vinculado à porta correspondente.
*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Quando PWR1 e PWR2 funcionam corretamente e o switch é alimentado por PWR1, leva de 10 a 20 segundos para que o LED PWR2 (amarelo) apague após o PWR2 ser desconectado.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
02 Introdução
Omada Campus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.
Botão de seleção de modo
Porto de Gestão
LED Console Port USB2.0 Port (Type-C/RJ45)
Porta 1G RJ45
10G SFP+ Slot LED
O painel frontal do S6500-48GP6XF é mostrado na figura a seguir.
Botão de seleção de modo
Porto de Gestão
LED Console Port USB2.0 Port (Type-C/RJ45)
Porta 1G RJ45
10G SFP+ Slot LED
The front panel of S6500-24M4Y is shown as the following figure.
Botão de seleção de modo
Porto de Gestão
LED Console Port USB2.0 Port (Type-C/RJ45)
Porta 2.5G RJ45
25G SFP28 Slot LED
The front panel of S6500-24MPP4Y is shown as the following figure.
Botão de seleção de modo
Porto de Gestão
LED Console Port USB2.0 Port (Type-C/RJ45)
Porta 2.5G RJ45
25G SFP28 Slot LED
Introdução 03
Omada Campus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.
Botão de seleção de modo
Porto de Gestão
LED Console Port USB2.0 Port (Type-C/RJ45)
Porta 2.5G RJ45
The front panel of S6500-48MPP6Y is shown as the following figure.
25G SFP28 Slot LED
Botão de seleção de modo
Porto de Gestão
LED Console Port USB2.0 Port (Type-C/RJ45)
Porta 2.5G RJ45
25G SFP28 Slot LED
LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST
Indicação
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Piscando: O interruptor funciona corretamente. Ligado ou Desligado: O interruptor funciona incorretamente.
Verde ligado: Todos os ventiladores funcionam corretamente. Amarelo ligado: Nem todos os ventiladores funcionam corretamente.
Ligado: A energia PoE restante é 7 W. Piscando: A energia PoE restante mantém 7 W após este LED ficar ligado por 2 minutos. Desligado: A energia PoE restante é > 7 W.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
04 Introdução
Omada Campus Stackable L3 Managed Switch
LIDERADO
Indicação
Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)
Verde Ligado: Executando a 1000 Mbps, mas sem atividade. Verde Piscando: Executando a 1000 Mbps e transmitindo ou recebendo dados. Amarelo Ligado: Executando a 10 Mbps/100 Mbps, mas sem atividade. Amarelo Piscando: Executando a 10 Mbps/100 Mbps e transmitindo ou recebendo dados. Desligado: Nenhum dispositivo está vinculado à porta correspondente.
Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)
Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Quando o LED STK está aceso)
Ativado: O número da porta indica o ID da unidade na topologia de pilha.
Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Quando o LED PoE está aceso)
Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port
Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***
Verde Ligado: Executando a 10 Gbps, mas sem atividade. Verde Piscando: Executando a 10 Gbps e transmitindo ou recebendo dados. Amarelo Ligado: Executando a 1 Gbps, mas sem atividade. Amarelo Piscando: Executando a 1 Gbps e transmitindo ou recebendo dados. Desligado: Nenhum dispositivo está vinculado à porta correspondente.
Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Introdução 05
Omada Campus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Porto de Gestão
LIDERADO
Console Port USB3.0 Port
(RJ45/Type-C)
Seleção de modo
Botão
10G SFP+ Slot (Port 1-26)
The front panel of S7500-48XF4C is shown as the following figure.
LED 25G SFP28 Slot (Port 27-32)
Botão de seleção de modo
Porto de Gestão
LED Console Port USB3.0 Port (Type-C/RJ45)
10G SFP+ Slot (Port 1-48)
The front panel of S7500-24Y4C is shown as the following figure.
100G QSFP28 Slot LED (Port 49-52)
Porto de Gestão
LIDERADO
Porta USB 3.0
Porta do console
(RJ45/Type-C)
Botão de seleção de modo
Slot SFP25 de 28G
LIDERADO
(Porta 1-24)
The front panel of S7500-48Y8C is shown as the following figure.
100G QSFP28 Slot (Port 25-28)
LED Mode Selection Button
25G SFP28 Slot (Port 1-48)
06 Introdução
100G QSFP28 Slot (Port 49-56)
Omada Campus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.
Botão de seleção de modo
Porta de gerenciamento LED
Porta USB 3.0
Console Port (Type-C/RJ45)
Slot QSFP100 de 28 G
LIDERADO
Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.
LED Indication LED
PWR1* PWR2
VENTILADOR DO SISTEMA
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Quando o LED SPD está aceso)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)
Indicação
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Piscando: O interruptor funciona corretamente. Ligado ou Desligado: O interruptor funciona incorretamente.
Verde: Todos os ventiladores funcionam corretamente. Amarelo: Nem todos os ventiladores funcionam corretamente.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
Observação:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Verde Ligado: Executando a 10 Gbps, mas sem atividade. Verde Piscando: Executando a 10 Gbps e transmitindo ou recebendo dados. Amarelo Ligado: Executando a 1 Gbps, mas sem atividade. Amarelo Piscando: Executando a 1 Gbps e transmitindo ou recebendo dados. Desligado: Nenhum dispositivo está vinculado à porta correspondente.
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Introdução 07
Omada Campus Stackable L3 Managed Switch
LIDERADO
Indicação
Port 27-32 of S7500-26XF6Y ***
(Quando o LED SPD está aceso)
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)
Verde Ligado: Executando a 100 Gbps, mas sem atividade. Verde Piscando: Executando a 100 Gbps e transmitindo ou recebendo dados. Amarelo Ligado: Executando a 40 Gbps, mas sem atividade. Amarelo Piscando: Executando a 40 Gbps e transmitindo ou recebendo dados. Desligado: Nenhum dispositivo está vinculado à porta correspondente.
Observação:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)
Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Quando o LED STK está aceso)
Ativado: O número da porta indica o ID da unidade na topologia de pilha.
*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Management Port Designed to connnect the device for management through web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.
08 Introdução
Omada Campus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature
Modelo
1000M
2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB
RJ45 Port RJ45 Port Slot
Slot
Slot
Porta
Porto Porto
S6500-24G4XF
24
/
4
/
/
S6500-48G6XF
48
/
6
/
/
S6500-24GP4XF
24
/
4
/
/
S6500-48GP6XF
48
/
6
/
/
S6500-24M4Y
/
24
/
4
/
S6500-24MPP4Y
/
24
/
4
/
S6500-48M6Y
/
48
/
6
/
S6500-48MPP6Y
/
48
/
6
/
S7500-26XF6Y
/
/
26
6
/
S7500-48XF4C
/
/
48
/
4
S7500-24Y4C
/
/
/
24
4
S7500-48Y8C
/
/
/
48
8
S7500-32C
/
/
/
/
32
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Security Slot Grounding Terminal Power Socket
Locking Strap Slot
Observação: PWR1 é a fonte de alimentação primária e tem prioridade sobre PWR2.
Introdução 09
Omada Campus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Slot de segurança Kensington
LIDERADO
Terminal de Aterramento
Módulo de fornecimento de energia
LIDERADO
Locking Strap Slot
Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Terminal de Aterramento
LIDERADO
Power Supply Module Locking Strap Slot
LIDERADO
Slot de segurança Kensington
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.
O painel traseiro do S7500-48Y8C é mostrado na figura a seguir. A figura é apenas para fins de demonstração. O seu switch pode ter aparência diferente da mostrada.
Terminal de Aterramento
LIDERADO
LIDERADO
Correia de bloqueio
Slot
Módulo de fornecimento de energia
10 Introdução
ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED
Omada Campus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
LEDLED
Locking Strap Slot
Power Supply Module Kensington Security Slot
Terminal de Aterramento
LIDERADO
Locking Strap Slot
Módulo de fornecimento de energia
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.
Introdução 11
Omada Campus Stackable L3 Managed Switch
Capítulo 2 Instalação
2.1 Conteúdo da embalagem
Certifique-se de que o pacote contém os seguintes itens. Entre em contato com seu distribuidor se algum dos itens listados estiver danificado ou faltando. As figuras são apenas para demonstração. Os itens reais podem diferir em aparência e quantidade dos descritos.
Trocar
Cabo de alimentação e cabo de console
Guia de instalação
Solução de rede de negócios
Guia de instalação
Omada Campus Stackable L3 Managed Switch
Suportes de montagem, parafusos e pés de borracha
2.2 Precauções de segurança
Para evitar danos ao dispositivo e ferimentos corporais causados pelo uso indevido, você deve observar as seguintes regras.
Precauções de segurança: Mantenha a energia desligada durante a instalação. Use uma pulseira antiestática e certifique-se de que ela tenha bom contato com a pele e esteja
bem aterrado. Use apenas o cabo de alimentação fornecido com o interruptor. Certifique-se de que o volume de alimentaçãotage corresponde às especificações indicadas no painel traseiro do
interruptor. Certifique-se de que o interruptor esteja instalado em um ambiente bem ventilado e que seu orifício de ventilação não esteja
bloqueado. Não abra ou remova a tampa do interruptor. Antes de limpar o dispositivo, corte a fonte de alimentação. Não limpe com pano aquoso e nunca
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Requisitos do site
Temperatura/Umidade
12 Instalação
Omada Campus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
A poeira acumulada no interruptor pode ser absorvida pela eletricidade estática e resultar em mau contato dos pontos de contato de metal. Algumas medidas foram tomadas para o dispositivo para evitar eletricidade estática, mas eletricidade estática muito forte pode causar danos mortais aos elementos eletrônicos na placa de circuito interna. Para evitar o efeito da eletricidade estática na operação do interruptor, dê muita importância aos seguintes itens: Limpe o dispositivo regularmente e mantenha o ar interno limpo. Mantenha o dispositivo bem aterrado e certifique-se de que a eletricidade estática tenha sido transferida. Interferência eletromagnética
Elementos eletrônicos, incluindo capacitância e indutância no dispositivo, podem ser afetados por interferências externas, como emissão conduzida por acoplamento de capacitância, acoplamento de indutância e acoplamento de impedância. Para diminuir as interferências, certifique-se de tomar as seguintes medidas: Use a fonte de alimentação que pode filtrar efetivamente a interferência da rede elétrica. Mantenha o dispositivo longe de dispositivos de alta frequência e corrente forte, como transmissores de rádio
estação. Use blindagem eletromagnética quando necessário. Proteção contra raios
Instalação 13
Omada Campus Stackable L3 Managed Switch
Vol extremamente altotagAs correntes podem ser produzidas instantaneamente quando ocorre um raio e o ar no caminho da descarga elétrica pode ser aquecido instantaneamente até 20,000 °C. Como esta corrente instantânea é forte o suficiente para danificar dispositivos eletrônicos, devem ser tomadas medidas de proteção contra raios mais eficazes. Certifique-se de que o rack e o dispositivo estejam bem aterrados. Certifique-se de que a tomada elétrica tenha um bom contato com o solo. Mantenha um sistema de cabeamento razoável e evite raios induzidos. Use o sinal SPD (Dispositivo de proteção contra surtos) ao fazer a fiação externa.
Observação: Para obter medidas detalhadas de proteção contra raios, consulte o Guia de Proteção contra Raios em: https://support.omadanetworks.com/r/1004/. Local de instalação
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Ferramentas de instalação
Chave de fenda Phillips com proteção antiestática para o pulso Cabos
Nota: Essas ferramentas não estão incluídas em nosso produto. Se necessário, você pode adquiri-los separadamente.
2.4 Instalação do produto
O switch foi projetado com recurso de dissipação de calor de frente para trás. Quando funciona, o ar circula conforme mostrado abaixo. Para melhor dissipação de calor, instale o aparelho em um ambiente bem ventilado e deixe espaços de 5 a 10 cm ao redor do aparelho.
14 Instalação
Figura 2-1
Circulação de ar
Omada Campus Stackable L3 Managed Switch
Instalação de desktop
Para instalar o dispositivo na área de trabalho, siga os passos:
1. Coloque o dispositivo em uma superfície plana que seja forte o suficiente para suportar todo o peso do dispositivo com todos os acessórios.
2. Remova os papéis adesivos dos pés de borracha.
3. Fixe os pés de borracha na parte inferior do dispositivo para evitar que ele escorregue quando colocado sobre uma mesa.
Figura 2-2
Instalação de desktop
Pés na parte inferior do entalhe do dispositivo
Instalação de Rack
O pacote inclui 6 pares de suportes de montagem em rack diferentes, suas fotos estão mostradas abaixo e podem diferir dos produtos reais.
Figura 2-3
Suportes de montagem
Screw Hole Group 2
Bracket D Bracket C Bracket B Bracket A
Screw Hole Group 1
Screw Hole Group 3
Suporte F
Screw Hole Group 4-2 (for device with 420mm depth)
Screw Hole Group 5
Furo do parafuso
Grupo 4-1
Screw Hole Group 4-3
(for device with 380mm depth)
(for device with
460mm depth)
Suporte E
Instalação 15
Omada Campus Stackable L3 Managed Switch
Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:
Método
Demonstração
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)
Rack Distance
(For device with a depth of 380mm)
Rack Distance
(For device with a depth of 420mm)
Rack Distance
(For device with a depth of 460mm)
498-640mm 538-680mm 578-720mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)
477-498mm 517-538mm 557-578mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)
429-477mm 469-517mm 509-557mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)
410-429mm 450-469mm 490-509mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)
357-410mm 397-450mm 437-490mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)
282-410mm 322-450mm 362-490mm
16 Instalação
Omada Campus Stackable L3 Managed Switch
Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)
555-936mm 555-936mm 555-936mm
Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)
743-1121mm 743-1121mm 743-1121mm
Para instalar o dispositivo, siga as instruções descritas abaixo:
1. Attach the M6 nuts to the racks.
Figura 2-4
Securing M6 Nuts
×8
2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.
Figura 2-5
Installing Brackets on Racks
or
3. Attach the brackets A & D/F to the switch with the provided M3 screws.
Instalação 17
Omada Campus Stackable L3 Managed Switch
Figura 2-6
Installing Brackets on Switch
4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.
Figura 2-7
Installing Switch on Racks
Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.
18 Instalação
Omada Campus Stackable L3 Managed Switch
Instalação do Módulo de Fonte de Alimentação
S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.
Figura 2-8
Appearance of the Power Supply Module
Conector do cabo de alimentação CA
FAN
Clipes de retenção
Extraction Handle
LIDERADO
Locking Strap Slot Release Handle
Se você precisar adicionar mais um módulo de fonte de alimentação, siga as etapas:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Press the extraction handle of the module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
3. Release the extraction handle to fix the power supply module in place.
Figura 2-9
Instalando o Módulo de Fonte de Alimentação
Alça de liberação
Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
Instalação 19
Omada Campus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap
Se você precisar remover o módulo de fonte de alimentação, siga as etapas:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Instalação do módulo de ventilador
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Figura 2-11 Aparência do Módulo de Ventilador
LIDERADO
20 Instalação
Extraction Handle Retainer Clips Release Handle
Omada Campus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded. 2. Press the extraction handle of the module with one hand, and pull the extraction handle until the
module completely comes out of the chassis.
Figura 2-12 Removendo um Módulo de Ventilador Danificado
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Instalação 21
Omada Campus Stackable L3 Managed Switch
Capítulo 3 Conexão
3.1 Porta Ethernet
Conecte uma porta Ethernet do switch ao computador pelo cabo RJ45 como mostra a figura a seguir.
Figura 3-1
Conectando a porta RJ45
Porta RJ45
RJ45 Cabo
3.2 10G SFP+/25G SFP28/100G QSFP28 Slot
The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module
Figura 3-2
Inserting the Fiber Module
Slot Fiber Module
3.3 porta de console
A CLI (Command Line Interface) permite que você gerencie o switch, permitindo que você carregue a CLI após conectar os PCs ou terminais à porta do console no switch por meio de um cabo (um cabo de console RJ45 é fornecido, enquanto o cabo Tipo C não é fornecido)
Conecte a porta do console RJ45 do dispositivo ao seu computador pelo cabo do console, conforme mostra a figura a seguir.
22 Conexão
Figura 3-3
Conectando a porta do console (RJ45)
Omada Campus Stackable L3 Managed Switch
Conecte a porta do console Tipo C do dispositivo ao seu computador por meio do cabo Tipo C (não fornecido), conforme mostra a figura a seguir.
Figura 3-4
Conectando a porta do console (USB)
Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Verificar instalação
Após concluir a instalação, verifique os seguintes itens: Deve haver de 5 a 10 cm de espaço livre ao redor do dispositivo para ventilação e certifique-se de que o fluxo de ar
é adequado. O voltage da fonte de alimentação atende ao requisito do volume de entradatage do dispositivo. O soquete de energia, o dispositivo e o rack estão bem aterrados. O dispositivo está conectado corretamente a outros dispositivos de rede.
Conexão 23
Omada Campus Stackable L3 Managed Switch
3.5 Ligar
Conecte o conector fêmea do cabo de alimentação fornecido na tomada do dispositivo e conecte o conector positivo em uma tomada elétrica, conforme mostra a figura a seguir. Certifique-se de que o volumetage da fonte de alimentação atende ao requisito do volume de entradatage (100-240 V~ 50/60 Hz).
Figura 3-5
Conectando à fonte de alimentação
Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.
3.6 Inicialização
Depois que o dispositivo é ligado, ele inicia o autoteste de inicialização. Uma série de testes é executada automaticamente para garantir que o dispositivo funcione corretamente. Durante esse tempo, seus indicadores LED responderão na seguinte ordem:
1. O indicador LED PWR fica aceso o tempo todo. O LED SYS e os indicadores LED de todas as portas ficam apagados.
2. Após cerca de um minuto, o LED SYS e os indicadores LED de todas as portas piscarão momentaneamente e depois desligarão.
3. Vários segundos depois, o indicador SYS LED piscará, o que representa uma inicialização bem-sucedida.
3.7 Topologia de Pilha
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:
Trocar
Modelo(s) compatível(is)
Quantidade
S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
24 Conexão
Omada Campus Stackable L3 Managed Switch
S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S7500-26XF6Y S7500-26XF6Y
S7500-48XF4C S7500-48XF4C
S7500-24Y4C S7500-24Y4C
S7500-48Y8C S7500-48Y8C
S7500-32C
S7500-32C
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
Existem três estruturas de topologia de pilha para diferentes cenários. Crie a topologia adequada de acordo com suas necessidades:
1. Topologia de cadeia: A topologia de cadeia é relativamente simples e não requer conexão de cabo entre a primeira e a última unidade. É adequada para empilhamento de longa distância, mas sua confiabilidade é relativamente baixa.
Figura 3-6
Topologia de cadeia
Grupo de portas de empilhamento 2
Grupo de portas de empilhamento 1
…
2. Topologia em anel: A topologia em anel tem maior confiabilidade em comparação com a topologia em cadeia. Quando uma das cadeias na topologia em anel é desconectada, a topologia em anel se torna uma topologia em cadeia, mas todo o sistema de pilha ainda pode funcionar normalmente. A topologia em anel requer conexão de cabo entre a primeira e a última unidade, portanto, não é adequada para empilhamento de longa distância.
Figura 3-7
Topologia de anel
Grupo de portas de empilhamento 2
Grupo de portas de empilhamento 1
…
Conexão 25
Omada Campus Stackable L3 Managed Switch
3. Topologia em estrela: a topologia em estrela conecta os switches a um switch principal central, portanto, ela pode aumentar significativamente a taxa de encaminhamento de dados entre os switches membros, ao mesmo tempo em que fornece gerenciamento unificado.
Figura 3-8
Topologia Estrela
Grupo de portas de empilhamento 2
Grupo de portas de empilhamento 3
Grupo de portas de empilhamento 1
…
Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.
26 Conexão
Omada Campus Stackable L3 Managed Switch
Capítulo 4 Configuração
4.1 Configuração finalizadaview
O switch oferece suporte a duas opções de configuração:
Modo autônomo: configure e gerencie o switch individualmente. Modo controlador: configure e gerencie os dispositivos de rede centralmente. É recomendado no
rede em larga escala, que consiste em dispositivos em massa, como pontos de acesso, switches e gateways.
Observação: quando a chave é alterada do modo independente para o modo do controlador, as configurações da chave são perdidas. Para obter detalhes, consulte os documentos relacionados no centro de download de nosso oficial website: https://support.omadanetworks.com/product/.
4.2 Modo Independente
No modo autônomo, use um computador para configurar e gerenciar o switch usando GUI (interface gráfica do usuário) ou CLI (interface de linha de comando).
Figura 4-1
Topologia para modo autônomo
Trocar
PC
Usando a GUI
1. Para acessar a página de gerenciamento do switch, certifique-se de que o switch e o computador estejam na mesma sub-rede. Abra um navegador e digite o endereço IP do switch no campo de endereço e pressione a tecla Enter.
Se o switch obtiver o endereço IP do servidor DHCP (normalmente um gateway), encontre o endereço IP do switch no servidor DHCP.
Caso contrário, use o endereço IP padrão 192.168.0.1 para iniciar a página de gerenciamento do switch.
2. Ao efetuar login pela primeira vez, defina o nome de usuário e a senha para proteger melhor sua rede e seus dispositivos. Depois disso, o sistema o redirecionará automaticamente para a interface de login para autenticação com as credenciais recém-criadas.
3. Após um login bem-sucedido, a página principal aparecerá. Você pode clicar nos menus na parte superior e esquerda para configurar as funções correspondentes.
Para obter as configurações detalhadas, consulte o Guia do usuário e o Guia CLI. Os guias podem ser encontrados no centro de download de nosso site oficial website: https://support.omadanetworks.com/product/.
Usando a CLI Configure uma conexão Telnet ou SSH para acessar o switch via CLI.
Configuração 27
Omada Campus Stackable L3 Managed Switch
Use a porta do console para acessar o switch. Ao usar a porta do console, inicie o programa de emulação de terminal (como o Hyper Terminal) no PC e configure o programa de emulação de terminal da seguinte forma:
Taxa de transmissão 38400 bps
Bits de dados 8
Paridade Nenhuma
Parar bits 1
Controle de fluxo Nenhum
Para obter as configurações detalhadas, consulte o Guia do usuário e o Guia CLI. Os guias podem ser encontrados no centro de download de nosso site oficial website: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.
4.3 Modo de controlador
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.
Via Omada Pro Hardware Controller (C5300)
Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).
Figura 4-2
Manage the network via Omada Pro Hardware Controller (C5300)
Interruptor de gateway
Omada Pro Hardware Controller (C5300) EAP
28 Configuração
PAA
PAA
Clientes
Omada Campus Stackable L3 Managed Switch
Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.
1. Encontre o endereço IP do gateway. Abra a linha de comando no seu PC e digite ipconfig. Na lista de resultados, encontre o Gateway Padrão, que também é o endereço IP do gateway.
2. Lançar um web navegador e digite o endereço IP do gateway. Faça login no gateway web página. Em seguida, vá para Rede > LAN > Lista de clientes DHCP para encontrar o endereço IP do seu controlador de acordo com seu endereço MAC.
3. Digite o endereço IP do seu controlador na barra de endereços para abri-lo web página.
4. On the Omada Pro Controller’s web página, siga o assistente para concluir a configuração rápida.
5. Após a configuração rápida, a página de login é exibida. Digite o nome de usuário e a senha que você criou e clique em Log in. Em seguida, você pode configurar o controlador posteriormente.
6. Se você deseja gerenciar os dispositivos remotamente, siga os próximos passos:
a. Certifique-se de que o Cloud Access esteja habilitado no seu controlador. Por padrão, o Cloud Access está habilitado. Certifique-se de que o LED Cloud esteja piscando lentamente.
b. Lançar um web navegador e digite https://omada.tplinkcloud.com na barra de endereço. Digite seu TP-Link ID e senha para fazer login. Clique em + Adicionar controlador e escolha Controlador de hardware para adicionar seu controlador. Em seguida, você pode configurar ainda mais o controlador.
For more details, refer to the Installation Guide of C5300.
Através do controlador de software Omada Pro
Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.
Figura 4-3
Gerencie a rede via Omada Pro Software Controller
Porta de entrada
Trocar
Controlador
Controlador de software Omada Pro AP
AP
AP
rodando no PC Host
Clientes
Configuração 29
Omada Campus Stackable L3 Managed Switch
1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web página. Caso contrário, clique em Iniciar um navegador para gerenciar a rede.
2. On the Omada Pro Controller’s web página, siga o assistente para concluir a configuração rápida.
3. Após a configuração rápida, a página de login é exibida. Digite o nome de usuário e a senha que você criou e clique em Log in. Em seguida, você pode configurar o controlador posteriormente.
4. Se você deseja gerenciar os dispositivos remotamente, siga os próximos passos:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web página, vá para Configurações > Cloud Access para habilitar o Cloud Access e vincular seu TP-Link ID. Se você o configurou na configuração rápida, pule esta etapa.
b. Lançar um web navegador e digite https://omada.tplinkcloud.com na barra de endereço. Digite seu TP-Link ID e senha para fazer o login. Uma lista de controladores que foram vinculados ao seu TP-Link ID aparecerá. Em seguida, você pode clicar em Iniciar para configurar o controlador.
Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.
Via controlador baseado em nuvem Omada Pro
O controlador baseado em nuvem Omada Pro é uma boa alternativa sem a necessidade de instalar o controlador de software em um PC.
Licenças precisam ser adquiridas adicionalmente.
Figura 4-4
Gerencie a rede por meio do controlador baseado em nuvem Omada Pro
Nuvem Omada
Porta de entrada
Trocar
AP
AP
AP
AP
Clientes
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Log in with
your TP-Link ID.
30 Configuração
Omada Campus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
you can launch the controller to adopt and manage devices. * Omada App With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official website: https://support.omadanetworks.com/product/.
Configuração 31
Omada Campus Stackable L3 Managed Switch
Apêndice A Solução de problemas
T1. O que posso fazer se esquecer o nome de usuário e a senha do switch?
1. Conecte a porta do console do PC à porta do console do switch e abra um programa de emulação de terminal.
2. Desligue e reinicie o switch. Execute a ação indicada pelo programa de emulação de terminal para chegar ao menu bootUtil. A ação difere de produto para produto. As ações possíveis estão listadas abaixo: · Pressione qualquer tecla para parar a inicialização automática. · Pressione CTRL-B para chegar ao menu bootUtil.
3. O menu bootUtil será exibido. Digite o número 6 para selecionar a opção "Recuperação de senha" e digite Y para excluir todos os usuários e senhas. Em seguida, você poderá redefinir o nome de usuário e a senha.
P2. Por que o LED PWR funciona de forma anormal? O LED PWR/Power deve estar aceso quando o sistema de energia estiver funcionando normalmente. Se o LED PWR/Power funcionar de forma anormal, siga os seguintes passos:
1. Certifique-se de que o cabo de alimentação esteja conectado corretamente e que o contato de alimentação esteja normal. 2. Certifique-se de que o volumetage da fonte de alimentação atende ao requisito do volume de entradatage do
trocar.
Q3. O que devo fazer se não conseguir acessar o web página de gerenciamento? Tente o seguinte:
1. Verifique cada LED de porta no switch e certifique-se de que o cabo Ethernet esteja conectado corretamente. 2. Tente outra porta no switch e certifique-se de que o cabo Ethernet seja adequado e funcione normalmente. 3. Desligue o switch e, depois de um tempo, ligue-o novamente. 4. Certifique-se de que o endereço IP do seu PC esteja definido dentro da sub-rede do switch. 5. Se você ainda não conseguir acessar a página de configuração, redefina o switch para os padrões de fábrica. Então
o endereço IP do seu PC deve ser definido como 192.168.0.x (“x” é qualquer número de 2 a 254) e a máscara de sub-rede como 255.255.255.0.
Q4. Por que o emulador de terminal não está sendo exibido corretamente? Tente o seguinte:
1. Certifique-se de que a fonte de alimentação esteja normal e o cabo do console esteja conectado corretamente. 2. Verifique se o cabo do console é do tipo certo. 3. Certifique-se de que os parâmetros do programa de emulação de terminal estejam corretos: configure Bits por segundo
como 38400, bits de dados como 8, paridade como nenhum, bits de parada como 1 e controle de fluxo como nenhum.
32 Apêndice A Solução de problemas
Omada Campus Stackable L3 Managed Switch
Apêndice B Especificações
Specifications for S6500 Series Switches
Item
Contente
IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x
Padrões
IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)
IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)
10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)
S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54
Apêndice B Especificações 33
Omada Campus Stackable L3 Managed Switch
Orçamento PoE
For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)
Operating Temperature & Altitude
For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters
Temperatura de armazenamento -40 °C a 70 °C (-40 °F a 158 °F)
Umidade operacional 10% a 90% RH Sem condensação
Umidade de armazenamento
5% a 90% RH Sem condensação
34 Apêndice B Especificações
Omada Campus Stackable L3 Managed Switch
Specifications for S7500 Series Switches
Item
Contente
Padrões
IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)
1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)
LIDERADO
Operating Temperature & Altitude
S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
Temperatura de armazenamento -40 °C a 70 °C (-40 °F a 158 °F)
Umidade operacional 10% a 90% RH Sem condensação
Umidade de armazenamento
5% a 90% RH Sem condensação
For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
A altitude suportada é do nível do mar até 5000 m. Vale ressaltar que quando a altitude estiver acima de 2000 m, para cada 220 metros de aumento de altitude, a temperatura máxima de operação cairá 1°C (1.8°F).
Apêndice B Especificações 35
Omada Campus Stackable L3 Managed Switch
Especificações para módulos de fonte de alimentação
PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)
Entrada de energia
100 V240 V~ 50/60 Hz 8A
100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)
100 V240 V~ 50/60 Hz 7A
Volume de saídatage
Primary: 53.5 VDC Standby: 12 VDC
Primary: 53.5 VDC Standby: 12 VDC
Primary: 12 VDC Standby: 12 VDC
Corrente de saída
9.35 A (máximo)
16.5 A (máximo)
45 A (máximo)
Potência de saída
500 W (máximo)
900 W (máximo)
550 W (máximo)
Altitude operacional
For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m
36 Apêndice B Especificações
Aviso de marca CE
Este é um produto de classe A. Em um ambiente doméstico, este produto pode causar interferência de rádio, em cujo caso o usuário pode ser obrigado a tomar medidas adequadas.
Declaração de conformidade da UE
A TP-Link declara que o switch está em conformidade com os requisitos essenciais e outras disposições relevantes das Diretivas 2014/30/UE, 2014/35/UE, 2011/65/UE e (UE) 2015/863. A Declaração de Conformidade da UE original pode ser encontrada em https://www.tp-link.com/en/support/ce/
Declaração de conformidade do Reino Unido
A TP-Link declara que o switch está em conformidade com os requisitos essenciais e outras disposições relevantes dos Regulamentos de Compatibilidade Eletromagnética de 2016 e dos Regulamentos de Equipamentos Elétricos (Segurança) de 2016. A Declaração de Conformidade original do Reino Unido pode ser encontrada em https://www.tp-link.com/support/ukca/
, .
CUIDADO:
Fusível neutro e de dois polos. Desconecte a rede elétrica antes de fazer a manutenção.
Informações de segurança
· Mantenha o dispositivo longe de água, fogo, umidade ou ambientes quentes. · Não tente desmontar, consertar ou modificar o dispositivo. Se precisar de manutenção, entre em contato conosco. · Coloque o dispositivo com a superfície inferior voltada para baixo. · O plugue do cabo de alimentação é usado como dispositivo de desconexão, a tomada deve ser
facilmente acessível. · Ligue o produto às tomadas de parede com ligação à terra através do cabo de alimentação
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
baterias.
· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.
Leia e siga as informações de segurança acima ao operar o dispositivo. Não podemos garantir que nenhum acidente ou dano ocorrerá devido ao uso indevido do dispositivo. Use este produto com cuidado e opere por sua conta e risco.
Para obter suporte técnico, guias do usuário e outras informações, visite https://support.omadanetworks.com/ ou simplesmente escaneie o código QR.